About this Pocket Reference
A compact, printable handbook for Installation 343. It lives at the front of the First 72 Hours wing and again in the Reference wing. Use the search box on a phone, or print the bundled PDF and keep a paper copy with the 72-hour pamphlet.
This is not a license, a diagnosis, or a building code. Figures are compiled from U.S. government and public-domain sources cited under each section. For medicine, water treatment, structural work, and electrical premises wiring, verify the number in the cited manual before you bet a life or a building on it. Do not use this book as a substitute for a physician, pharmacist, licensed electrician, or engineer.
What this is not. It is not a copy of Glover’s Pocket Ref, the current Machinery’s Handbook, the National Electrical Code, or any other copyrighted handbook. Where a modern code is the controlling document (NEC ampacity, IRC span tables, vehicle torque), this book says so and stops.
Utah note. Many settled parts of the Wasatch Front sit near or above 4,000–5,000 feet. EPA boil-water times change at 5,000 feet. UTM is almost entirely zone 12N. Magnetic declination changes from year to year — use the rose on your map, not a memorized number.
Compiled 15 November 2026, America/Denver, for personal offline use. Primary sources: NIST SP 811 (2008) and SP 330 (2019) in reference/; EPA 816-F-15-003 (Sept 2017) in food-water/; NOAA/NWS public scales; USDA FoodData Central typical values; FM 21-76 and FM 4-25.11 in this archive; standard SI and AWG formulae (ASTM B258 / NBS).
Unit conversions
SI is the system this archive prefers for calculation. U.S. customary units are given because most of the hardware on this shelf is inch-based. Exact definitions below are from NIST SP 811 and SP 330 (2019 SI brochure), both in reference/.
Temperature
°F to °C: C = (F − 32) × 5/9. °C to °F: F = C × 9/5 + 32. Kelvin: K = C + 273.15. Absolute zero is 0 K = −273.15 °C = −459.67 °F. Ice point 0 °C; standard steam point 100 °C at 101325 Pa.
SI prefixes
| Prefix | Symbol | Factor |
|---|---|---|
| yotta | Y | 1024 |
| zetta | Z | 1021 |
| exa | E | 1018 |
| peta | P | 1015 |
| tera | T | 1012 |
| giga | G | 109 |
| mega | M | 106 |
| kilo | k | 103 |
| hecto | h | 102 |
| deka | da | 101 |
| deci | d | 10−1 |
| centi | c | 10−2 |
| milli | m | 10−3 |
| micro | μ | 10−6 |
| nano | n | 10−9 |
| pico | p | 10−12 |
| femto | f | 10−15 |
| atto | a | 10−18 |
| zepto | z | 10−21 |
| yocto | y | 10−24 |
Exact and conventional definitions
| Quantity | Value | Note |
|---|---|---|
| inch (international) | 25.4 mm exactly | since 1 July 1959 |
| avoirdupois pound | 0.45359237 kg exactly | NIST |
| U.S. liquid gallon (231 in3) | 3.785411784 L exactly | derived from the inch |
| U.S. liquid quart | 0.946352946 L | ¼ gallon |
| U.S. legal (survey) foot, pre-2023 | 1200/3937 m ≈ 0.3048006096 m | see NIST; do not mix with the international foot on old plats |
| international foot | 0.3048 m exactly | 0.3048 m |
| yard | 0.9144 m exactly | 3 international feet |
| avoirdupois ounce | 28.349523125 g | 1/16 lb |
| avoirdupois (short) ton | 2000 lb = 907.18474 kg | |
| long ton (UK) | 2240 lb ≈ 1016.0469 kg | |
| metric ton (tonne) | 1000 kg | |
| grain | 64.79891 mg exactly | 1/7000 lb |
| troy ounce (precious metals) | 31.1034768 g | 480 grains |
| atmosphere (standard) | 101325 Pa exactly | 14.69595 psi |
| bar | 100000 Pa exactly | |
| mmHg (conventional torr ≈) | 133.322 Pa | 1 atm = 760 mmHg |
| calorie (IT) | 4.1868 J | nutrition “Calorie” = 1 kcal = 1000 cal |
| British thermal unit (IT) | 1055.05585 J | ≈ 0.293071 W·h |
| horsepower (mechanical) | 745.6999 W | 550 ft·lbf/s |
| electronvolt | 1.602176634×10−19 J exactly | SI 2019 |
Length and area
| From | To | Multiply by | Note |
|---|---|---|---|
| in | mm | 25.4 | mm → in: ÷ 25.4 |
| ft | m | 0.3048 | m → ft: × 3.28084 |
| yd | m | 0.9144 | m → yd: × 1.09361 |
| mile (statute) | km | 1.609344 | km → mi: × 0.621371 |
| nautical mile | m | 1852 exactly | 1 kt = 1 nmi/h |
| mil (0.001 in) | μm | 25.4 | wire and sheet |
| fathom | ft | 6 | 1.8288 m |
| rod / pole | ft | 16.5 | 5.0292 m |
| chain (Gunter) | ft | 66 | 100 links; 80 ch = 1 mile |
| acre | ft2 | 43560 | 4046.856 m2; 640 acres = 1 section |
| hectare | m2 | 10000 | 2.47105 acres |
Volume
| From | To | Multiply by | Note |
|---|---|---|---|
| fl oz (U.S. liq) | mL | 29.57353 | 20 fl oz UK pint is not a U.S. pint |
| cup (U.S. legal) | mL | 240 | U.S. customary cup 236.588 mL; nutrition labels use 240 |
| pint (U.S. liq) | mL | 473.176 | 16 fl oz |
| quart (U.S. liq) | L | 0.946353 | 32 fl oz |
| gallon (U.S. liq) | L | 3.785412 | 231 in3 |
| gallon (U.S. liq) | in3 | 231 exactly | |
| ft3 | L | 28.31685 | 7.48052 U.S. gal |
| tablespoon | mL | 14.7868 | 3 tsp; ½ fl oz |
| teaspoon | mL | 4.92892 | often taken as 5 mL in medicine cups — read the cup |
| barrel (oil, 42 gal) | L | 158.987 | not a U.S. beer barrel (31 gal) |
| acre-foot | m3 | 1233.48 | 325,851 U.S. gal |
Mass
| From | To | Multiply by | Note |
|---|---|---|---|
| oz | g | 28.3495 | avoirdupois |
| lb | kg | 0.45359237 | lb → kg exact |
| stone | lb | 14 | 6.35029 kg |
| cwt (short, U.S.) | lb | 100 | 45.3592 kg |
| slug | kg | 14.59390 | mass that 1 lbf accelerates at 1 ft/s2 |
Pressure
| From | To | Multiply by | Note |
|---|---|---|---|
| psi | kPa | 6.894757 | kPa → psi: × 0.145038 |
| psf | Pa | 47.88026 | |
| atm | psi | 14.69595 | 101.325 kPa |
| bar | psi | 14.50377 | 100 kPa |
| inHg (0 °C conv.) | kPa | 3.38639 | barometer |
| inH2O (60 °F) | Pa | 248.84 | duct and gas draft |
| mmHg / torr | Pa | 133.322 | |
| kgf/cm2 | kPa | 98.0665 | ≈ 14.223 psi |
Energy and power
| From | To | Multiply by | Note |
|---|---|---|---|
| ft·lbf | J | 1.355818 | |
| kcal (IT) | kJ | 4.1868 | food Calorie = 1 kcal |
| Btu (IT) | kJ | 1.055056 | 3412 Btu ≈ 1 kWh |
| kWh | MJ | 3.6 exactly | 3,600,000 J |
| hp·h | MJ | 2.68452 | mechanical hp |
| therm (U.S.) | MJ | 105.5 | ≈ 100,000 Btu |
Force: 1 lbf = 4.448222 N. 1 kgf = 9.80665 N. 1 kip = 1000 lbf.
Speed: 1 mph = 1.609344 km/h = 0.44704 m/s. 1 knot = 1.852 km/h exactly = 1.15078 mph.
Water at ~4 °C: density ≈ 1000 kg/m3 = 1.940 slug/ft3. 1 U.S. gal weighs about 8.34 lb at 60 °F. 1 ft3 of water weighs about 62.4 lb.
Inch fractions to decimal inches and millimetres
| n/64 | Reduced | inches | mm |
|---|---|---|---|
| 1/64 | — | 0.015625 | 0.397 |
| 2/64 | 1/32 | 0.03125 | 0.794 |
| 3/64 | — | 0.046875 | 1.191 |
| 4/64 | 1/16 | 0.0625 | 1.587 |
| 5/64 | — | 0.078125 | 1.984 |
| 6/64 | 3/32 | 0.09375 | 2.381 |
| 7/64 | — | 0.109375 | 2.778 |
| 8/64 | 1/8 | 0.125 | 3.175 |
| 9/64 | — | 0.140625 | 3.572 |
| 10/64 | 5/32 | 0.15625 | 3.969 |
| 11/64 | — | 0.171875 | 4.366 |
| 12/64 | 3/16 | 0.1875 | 4.762 |
| 13/64 | — | 0.203125 | 5.159 |
| 14/64 | 7/32 | 0.21875 | 5.556 |
| 15/64 | — | 0.234375 | 5.953 |
| 16/64 | 1/4 | 0.25 | 6.350 |
| 17/64 | — | 0.265625 | 6.747 |
| 18/64 | 9/32 | 0.28125 | 7.144 |
| 19/64 | — | 0.296875 | 7.541 |
| 20/64 | 5/16 | 0.3125 | 7.938 |
| 21/64 | — | 0.328125 | 8.334 |
| 22/64 | 11/32 | 0.34375 | 8.731 |
| 23/64 | — | 0.359375 | 9.128 |
| 24/64 | 3/8 | 0.375 | 9.525 |
| 25/64 | — | 0.390625 | 9.922 |
| 26/64 | 13/32 | 0.40625 | 10.319 |
| 27/64 | — | 0.421875 | 10.716 |
| 28/64 | 7/16 | 0.4375 | 11.112 |
| 29/64 | — | 0.453125 | 11.509 |
| 30/64 | 15/32 | 0.46875 | 11.906 |
| 31/64 | — | 0.484375 | 12.303 |
| 32/64 | 1/2 | 0.5 | 12.700 |
| 33/64 | — | 0.515625 | 13.097 |
| 34/64 | 17/32 | 0.53125 | 13.494 |
| 35/64 | — | 0.546875 | 13.891 |
| 36/64 | 9/16 | 0.5625 | 14.287 |
| 37/64 | — | 0.578125 | 14.684 |
| 38/64 | 19/32 | 0.59375 | 15.081 |
| 39/64 | — | 0.609375 | 15.478 |
| 40/64 | 5/8 | 0.625 | 15.875 |
| 41/64 | — | 0.640625 | 16.272 |
| 42/64 | 21/32 | 0.65625 | 16.669 |
| 43/64 | — | 0.671875 | 17.066 |
| 44/64 | 11/16 | 0.6875 | 17.462 |
| 45/64 | — | 0.703125 | 17.859 |
| 46/64 | 23/32 | 0.71875 | 18.256 |
| 47/64 | — | 0.734375 | 18.653 |
| 48/64 | 3/4 | 0.75 | 19.050 |
| 49/64 | — | 0.765625 | 19.447 |
| 50/64 | 25/32 | 0.78125 | 19.844 |
| 51/64 | — | 0.796875 | 20.241 |
| 52/64 | 13/16 | 0.8125 | 20.637 |
| 53/64 | — | 0.828125 | 21.034 |
| 54/64 | 27/32 | 0.84375 | 21.431 |
| 55/64 | — | 0.859375 | 21.828 |
| 56/64 | 7/8 | 0.875 | 22.225 |
| 57/64 | — | 0.890625 | 22.622 |
| 58/64 | 29/32 | 0.90625 | 23.019 |
| 59/64 | — | 0.921875 | 23.416 |
| 60/64 | 15/16 | 0.9375 | 23.812 |
| 61/64 | — | 0.953125 | 24.209 |
| 62/64 | 31/32 | 0.96875 | 24.606 |
| 63/64 | — | 0.984375 | 25.003 |
NIST Special Publication 811, Guide for the Use of the International System of Units (2008); NIST SP 330, The International System of Units (2019). Survey-foot caution: U.S. survey foot was deprecated; use the international foot (0.3048 m) unless an older plat explicitly uses the survey foot.
Math, geometry, and trigonometry
Algebra
- Quadratic: if ax2 + bx + c = 0, then x = [−b ± √(b2 − 4ac)] / (2a). Discriminant Δ = b2−4ac; Δ<0 means no real roots.
- Proportions: a/b = c/d ⇒ ad = bc.
- Percentage change: (new − old) / old × 100%.
- Compound growth: A = P (1 + r)n. Continuous: A = P ert.
- Logarithms: log(xy) = log x + log y; log(xn) = n log x; ln e = 1; log10 2 ≈ 0.3010; ln 10 ≈ 2.302585; change of base: logb a = ln a / ln b.
- Powers: (ab)n = an bn; am an = am+n; (am)n = amn; a−n = 1/an.
π ≈ 3.141592653589793. e ≈ 2.718281828459045. √2 ≈ 1.41421356. √3 ≈ 1.73205081. √5 ≈ 2.23606798. 1 radian = 180/π ≈ 57.2957795°. 1° = π/180 ≈ 0.01745329 rad.
Areas
| Shape | Area | Notes |
|---|---|---|
| Square, side a | A = a2 | P = 4a |
| Rectangle, sides a, b | A = a b | P = 2(a+b) |
| Triangle, base b, height h | A = b h / 2 | also √[s(s−a)(s−b)(s−c)], s = (a+b+c)/2 |
| Equilateral triangle, side a | A = (√3 / 4) a2 | height = (√3 / 2) a |
| Circle, radius r | A = π r2 | C = 2 π r; d = 2r |
| Annulus (ring), R, r | A = π (R2 − r2) | |
| Ellipse, semi-axes a, b | A = π a b | perimeter ≈ π [3(a+b) − √((3a+b)(a+3b))] (Ramanujan) |
| Trapezoid, bases a, b, height h | A = (a+b) h / 2 | |
| Regular hexagon, side a | A = (3√3 / 2) a2 | width flat-to-flat = √3 a |
| Sphere, radius r (surface) | A = 4 π r2 | volume below |
| Cylinder (lateral), r, h | A = 2 π r h | total + 2 π r2 |
| Cone (lateral), r, slant L | A = π r L | L = √(r2+h2) |
Volumes
| Shape | Volume |
|---|---|
| Cube, side a | V = a3 |
| Rectangular box | V = a b c |
| Cylinder | V = π r2 h |
| Sphere | V = (4/3) π r3 |
| Cone or pyramid | V = (1/3) × base area × height |
| Frustum of a cone (r, R, h) | V = (π h / 3) (R2 + R r + r2) |
| Torus, tube r, centerline R | V = 2 π2 R r2 |
| Barrel / tank approx. | prefer the manufacturer or a dip chart; do not guess fuel volume from a rust line |
Right triangles and trig
Pythagoras: c2 = a2 + b2 for the hypotenuse c. sin θ = opposite/hypotenuse, cos θ = adjacent/hypotenuse, tan θ = opposite/adjacent = sin/cos. Reciprocals: csc = 1/sin, sec = 1/cos, cot = 1/tan.
sin2θ + cos2θ = 1. Law of sines: a/sin A = b/sin B = c/sin C = 2R. Law of cosines: c2 = a2 + b2 − 2ab cos C.
Slope (grade) = rise/run. Percent grade = 100 × rise/run. A 100% grade is 45°. Roof pitch of 6/12 is a 6-inch rise in 12 inches of run (26.57°).
| θ (°) | sin | cos | tan |
|---|---|---|---|
| 0 | 0 | 1 | 0.0000 |
| 15 | 0.2588 | 0.9659 | 0.2679 |
| 30 | 0.5 | √3/2 ≈ 0.8660 | 1/√3 ≈ 0.5774 |
| 45 | √2/2 ≈ 0.7071 | √2/2 ≈ 0.7071 | 1 |
| 60 | √3/2 ≈ 0.8660 | 0.5 | √3 ≈ 1.7321 |
| 75 | 0.9659 | 0.2588 | 3.7321 |
| 90 | 1 | 0 | — |
| θ (°) | sin | cos | tan | rad |
|---|---|---|---|---|
| 0 | 0.0000 | 1.0000 | 0.0000 | 0.0000 |
| 5 | 0.0872 | 0.9962 | 0.0875 | 0.0873 |
| 10 | 0.1736 | 0.9848 | 0.1763 | 0.1745 |
| 15 | 0.2588 | 0.9659 | 0.2679 | 0.2618 |
| 20 | 0.3420 | 0.9397 | 0.3640 | 0.3491 |
| 25 | 0.4226 | 0.9063 | 0.4663 | 0.4363 |
| 30 | 0.5000 | 0.8660 | 0.5774 | 0.5236 |
| 35 | 0.5736 | 0.8192 | 0.7002 | 0.6109 |
| 40 | 0.6428 | 0.7660 | 0.8391 | 0.6981 |
| 45 | 0.7071 | 0.7071 | 1.0000 | 0.7854 |
| 50 | 0.7660 | 0.6428 | 1.1918 | 0.8727 |
| 55 | 0.8192 | 0.5736 | 1.4281 | 0.9599 |
| 60 | 0.8660 | 0.5000 | 1.7321 | 1.0472 |
| 65 | 0.9063 | 0.4226 | 2.1445 | 1.1345 |
| 70 | 0.9397 | 0.3420 | 2.7475 | 1.2217 |
| 75 | 0.9659 | 0.2588 | 3.7321 | 1.3090 |
| 80 | 0.9848 | 0.1736 | 5.6713 | 1.3963 |
| 85 | 0.9962 | 0.0872 | 11.4301 | 1.4835 |
| 90 | 1.0000 | 0.0000 | ∞ | 1.5708 |
Small-shop arithmetic
- Speed, distance, time: d = v t.
- Right-triangle layout (3-4-5): a 3-4-5 or 6-8-10 triangle is square. The 5-12-13 set also works.
- Circumference / π gives diameter. Useful when you can wrap a tape around a pipe but cannot measure across it.
- Board feet = thickness (in) × width (in) × length (ft) / 12.
- Weight of a steel plate ≈ 0.283 lb per in3, or 40.8 lb/ft2 per inch of thickness (see Material weights).
Standard Euclidean geometry and trigonometry; radian definition from NIST SI (the radian is a coherent SI unit).
Fasteners, threads, drill and tap
Unified threads (UNC coarse, UNF fine) and ISO metric coarse are the ones you will actually meet in a U.S. shop and on imported hardware. Pitch diameter and class-of-fit (1A/2A/3A) live in the public-domain Machinery’s Handbook 6th (1924) and in later standards; the table below is the everyday tap-drill chart for about 75% thread, which is what most jobbers cut in unhardened steel.
A 75% tap drill is a starting point, not a law. In hard steel or a deep hole, go slightly larger (shallower thread) so the tap survives. In soft or thin material you may want more thread engagement. Broken taps are worse than a slightly loose thread.
Unified National Coarse (UNC) — 75% tap drill
| Thread | Major Ø (in) | TPI | Tap drill | Note |
|---|---|---|---|---|
| #0-80* | 0.0600 | 80 | #56 (0.0465) | UNF actually; listed because #0 has no UNC |
| #1-64 | 0.0730 | 64 | #53 (0.0595) | |
| #2-56 | 0.0860 | 56 | #50 (0.0700) | |
| #3-48 | 0.0990 | 48 | #47 (0.0785) | |
| #4-40 | 0.1120 | 40 | #43 (0.0890) | |
| #5-40 | 0.1250 | 40 | #38 (0.1015) | |
| #6-32 | 0.1380 | 32 | #35 (0.1100) | |
| #8-32 | 0.1640 | 32 | #29 (0.1360) | |
| #10-24 | 0.1900 | 24 | #25 (0.1495) | |
| #12-24 | 0.2160 | 24 | #16 (0.1770) | |
| 1/4-20 | 0.2500 | 20 | #7 (0.2010) | very common |
| 5/16-18 | 0.3125 | 18 | F (0.2570) | |
| 3/8-16 | 0.3750 | 16 | 5/16 (0.3125) | |
| 7/16-14 | 0.4375 | 14 | U (0.3680) | |
| 1/2-13 | 0.5000 | 13 | 27/64 (0.4219) | |
| 9/16-12 | 0.5625 | 12 | 31/64 (0.4844) | |
| 5/8-11 | 0.6250 | 11 | 17/32 (0.5312) | |
| 3/4-10 | 0.7500 | 10 | 21/32 (0.6562) | |
| 7/8-9 | 0.8750 | 9 | 49/64 (0.7656) | |
| 1-8 | 1.0000 | 8 | 7/8 (0.8750) | |
| 1⅛-7 | 1.1250 | 7 | 63/64 (0.9844) | |
| 1¼-7 | 1.2500 | 7 | 1-7/64 (1.1094) | |
| 1½-6 | 1.5000 | 6 | 1-11/32 (1.3438) |
Unified National Fine (UNF) — 75% tap drill
| Thread | Major Ø (in) | TPI | Tap drill | Note |
|---|---|---|---|---|
| #1-72 | 0.0730 | 72 | #53 (0.0595) | |
| #2-64 | 0.0860 | 64 | #50 (0.0700) | |
| #3-56 | 0.0990 | 56 | #45 (0.0820) | |
| #4-48 | 0.1120 | 48 | #42 (0.0935) | |
| #5-44 | 0.1250 | 44 | #37 (0.1040) | |
| #6-40 | 0.1380 | 40 | #33 (0.1130) | |
| #8-36 | 0.1640 | 36 | #29 (0.1360) | |
| #10-32 | 0.1900 | 32 | #21 (0.1590) | |
| #12-28 | 0.2160 | 28 | #14 (0.1820) | |
| 1/4-28 | 0.2500 | 28 | #3 (0.2130) | |
| 5/16-24 | 0.3125 | 24 | I (0.2720) | |
| 3/8-24 | 0.3750 | 24 | Q (0.3320) | |
| 7/16-20 | 0.4375 | 20 | 25/64 (0.3906) | |
| 1/2-20 | 0.5000 | 20 | 29/64 (0.4531) | |
| 9/16-18 | 0.5625 | 18 | 33/64 (0.5156) | |
| 5/8-18 | 0.6250 | 18 | 37/64 (0.5781) | |
| 3/4-16 | 0.7500 | 16 | 11/16 (0.6875) | |
| 7/8-14 | 0.8750 | 14 | 13/16 (0.8125) | |
| 1-12 | 1.0000 | 12 | 59/64 (0.9219) | 1-14 is UNEF |
| 1-14 UNEF | 1.0000 | 14 | 15/16 (0.9375) |
Approximate 75% inch-series formula: tap-drill diameter ≈ major diameter − (1 / TPI). Then pick the nearest number, letter, or fractional drill.
ISO metric coarse — 75% tap drill
| Thread | Tap drill | Thread | Tap drill |
|---|---|---|---|
| M2 × 0.4 | 1.6 mm | M2.5 × 0.45 | 2.05 mm |
| M3 × 0.5 | 2.5 mm | M3.5 × 0.6 | 2.9 mm |
| M4 × 0.7 | 3.3 mm | M5 × 0.8 | 4.2 mm |
| M6 × 1.0 | 5.0 mm | M8 × 1.25 | 6.8 mm |
| M10 × 1.5 | 8.5 mm | M12 × 1.75 | 10.2 mm |
| M14 × 2.0 | 12.0 mm | M16 × 2.0 | 14.0 mm |
| M18 × 2.5 | 15.5 mm | M20 × 2.5 | 17.5 mm |
| M22 × 2.5 | 19.5 mm | M24 × 3.0 | 21.0 mm |
| M27 × 3.0 | 24.0 mm | M30 × 3.5 | 26.5 mm |
NPT pipe threads (nominal)
| Nominal | TPI | OD (in) approx. | Tap / int. drill often used | Close alternative |
|---|---|---|---|---|
| 1/8 | 27 | 0.405 | R (0.339) | 5/16 |
| 1/4 | 18 | 0.540 | 7/16 | 7/16 |
| 3/8 | 18 | 0.675 | 37/64 | 9/16 |
| 1/2 | 14 | 0.840 | 23/32 | 45/64 |
| 3/4 | 14 | 1.050 | 59/64 | 29/32 |
| 1 | 11½ | 1.315 | 1-5/32 | 1-9/64 |
| 1¼ | 11½ | 1.660 | 1-1/2 | 1-31/64 |
| 1½ | 11½ | 1.900 | 1-47/64 | 1-23/32 |
| 2 | 11½ | 2.375 | 2-7/32 | 2-3/16 |
Head markings (as found on the bolt, not on the box)
- SAE J429 Grade 2 (low or medium carbon): no marks, or in some lots a manufacturer mark only. Not for structural or automotive critical joints.
- Grade 5 (quenched and tempered): three radial hash marks on the head. Common automotive and machinery fastener.
- Grade 8: six radial hash marks. Higher strength, more brittle if abused. Do not weld Grade 8.
- Metric 8.8: marked 8.8. 10.9 and 12.9 are higher; 12.9 is quite hard and notch-sensitive. Property class ≈ 0.1 × the first number in hundreds of MPa tensile (8.8 ≈ 800 MPa tensile, 80% yield).
- Stainless markings (A2-70, A4-70, A4-80) are a different system — strength is lower than a Grade 8 of the same size, and you should not mix them as if they were equivalent.
- A bolt is only as strong as the nut, the tapped hole, and the joint design. A long, springy joint is not the same as a short, stiff one.
Typical dry tightening torque (non-critical)
Do not use this table for cylinder heads, wheels, suspension, rod bolts, pressure vessels, or any fastener the manufacturer gives a number for. Lubricated threads can take a much lower torque to reach the same tension (often 25–40% less). Rust, plating, and threadlocker all change the number. When the book that came with the machine specifies a torque, that book wins.
| Size | SAE Grade 5 (typical dry) | SAE Grade 8 (typical dry) | Note |
|---|---|---|---|
| #10-24 | 20–25 in·lbf | 28–32 in·lbf | use in·lbf, not ft·lbf |
| #10-32 | 22–28 in·lbf | 30–35 in·lbf | |
| 1/4-20 | 8 ft·lbf | 12 ft·lbf | |
| 1/4-28 | 10 | 14 | |
| 5/16-18 | 17 | 25 | |
| 5/16-24 | 19 | 27 | |
| 3/8-16 | 30 | 45 | |
| 3/8-24 | 35 | 50 | |
| 7/16-14 | 50 | 70 | |
| 7/16-20 | 55 | 80 | |
| 1/2-13 | 75 | 110 | |
| 1/2-20 | 85 | 120 | |
| 9/16-12 | 110 | 150 | |
| 5/8-11 | 150 | 210 | |
| 3/4-10 | 270 | 380 | |
| 7/8-9 | 430 | 600 | |
| 1-8 | 645 | 905 |
Clearance holes (close / free, approximate)
For a close-fit clearance, drill about 1/64 in over nominal on small bolts (¼ and 5/16) and 1/32 in over on ⅜–½. For a free fit (the hole is supposed to find the bolt), go another 1/32 in or so. A ¼-20 close clearance is often #7’s neighbor — letter C or 17/64; a free fit is often 9/32.
Number drill chart
| Drill | in | mm |
|---|---|---|
| #1 | 0.2280 | 5.79 |
| #2 | 0.2210 | 5.61 |
| #3 | 0.2130 | 5.41 |
| #4 | 0.2090 | 5.31 |
| #5 | 0.2055 | 5.22 |
| #6 | 0.2040 | 5.18 |
| #7 | 0.2010 | 5.11 |
| #8 | 0.1990 | 5.05 |
| #9 | 0.1960 | 4.98 |
| #10 | 0.1935 | 4.91 |
| #11 | 0.1910 | 4.85 |
| #12 | 0.1890 | 4.80 |
| #13 | 0.1850 | 4.70 |
| #14 | 0.1820 | 4.62 |
| #15 | 0.1800 | 4.57 |
| #16 | 0.1770 | 4.50 |
| #17 | 0.1730 | 4.39 |
| #18 | 0.1695 | 4.31 |
| #19 | 0.1660 | 4.22 |
| #20 | 0.1610 | 4.09 |
| #21 | 0.1590 | 4.04 |
| #22 | 0.1570 | 3.99 |
| #23 | 0.1540 | 3.91 |
| #24 | 0.1520 | 3.86 |
| #25 | 0.1495 | 3.80 |
| #26 | 0.1470 | 3.73 |
| #27 | 0.1440 | 3.66 |
| #28 | 0.1405 | 3.57 |
| #29 | 0.1360 | 3.45 |
| #30 | 0.1285 | 3.26 |
| #31 | 0.1200 | 3.05 |
| #32 | 0.1160 | 2.95 |
| #33 | 0.1130 | 2.87 |
| #34 | 0.1110 | 2.82 |
| #35 | 0.1100 | 2.79 |
| #36 | 0.1065 | 2.71 |
| #37 | 0.1040 | 2.64 |
| #38 | 0.1015 | 2.58 |
| #39 | 0.0995 | 2.53 |
| #40 | 0.0980 | 2.49 |
| #41 | 0.0960 | 2.44 |
| #42 | 0.0935 | 2.37 |
| #43 | 0.0890 | 2.26 |
| #44 | 0.0860 | 2.18 |
| #45 | 0.0820 | 2.08 |
| #46 | 0.0810 | 2.06 |
| #47 | 0.0785 | 1.99 |
| #48 | 0.0760 | 1.93 |
| #49 | 0.0730 | 1.85 |
| #50 | 0.0700 | 1.78 |
| #51 | 0.0670 | 1.70 |
| #52 | 0.0635 | 1.61 |
| #53 | 0.0595 | 1.51 |
| #54 | 0.0550 | 1.40 |
| #55 | 0.0520 | 1.32 |
| #56 | 0.0465 | 1.18 |
| #57 | 0.0430 | 1.09 |
| #58 | 0.0420 | 1.07 |
| #59 | 0.0410 | 1.04 |
| #60 | 0.0400 | 1.02 |
| #61 | 0.0390 | 0.99 |
| #62 | 0.0380 | 0.97 |
| #63 | 0.0370 | 0.94 |
| #64 | 0.0360 | 0.91 |
| #65 | 0.0350 | 0.89 |
| #66 | 0.0330 | 0.84 |
| #67 | 0.0320 | 0.81 |
| #68 | 0.0310 | 0.79 |
| #69 | 0.0292 | 0.74 |
| #70 | 0.0280 | 0.71 |
| #71 | 0.0260 | 0.66 |
| #72 | 0.0250 | 0.64 |
| #73 | 0.0240 | 0.61 |
| #74 | 0.0225 | 0.57 |
| #75 | 0.0210 | 0.53 |
| #76 | 0.0200 | 0.51 |
| #77 | 0.0180 | 0.46 |
| #78 | 0.0160 | 0.41 |
| #79 | 0.0145 | 0.37 |
| #80 | 0.0135 | 0.34 |
Letter drill chart
| Drill | in | mm |
|---|---|---|
| A | 0.2340 | 5.94 |
| B | 0.2380 | 6.05 |
| C | 0.2420 | 6.15 |
| D | 0.2460 | 6.25 |
| E | 0.2500 | 6.35 |
| F | 0.2570 | 6.53 |
| G | 0.2610 | 6.63 |
| H | 0.2660 | 6.76 |
| I | 0.2720 | 6.91 |
| J | 0.2770 | 7.04 |
| K | 0.2810 | 7.14 |
| L | 0.2900 | 7.37 |
| M | 0.2950 | 7.49 |
| N | 0.3020 | 7.67 |
| O | 0.3160 | 8.03 |
| P | 0.3230 | 8.20 |
| Q | 0.3320 | 8.43 |
| R | 0.3390 | 8.61 |
| S | 0.3480 | 8.84 |
| T | 0.3580 | 9.09 |
| U | 0.3680 | 9.35 |
| V | 0.3770 | 9.58 |
| W | 0.3860 | 9.80 |
| X | 0.3970 | 10.08 |
| Y | 0.4040 | 10.26 |
| Z | 0.4130 | 10.49 |
Fractional drills follow the usual 1/64-inch steps; see the inch-fraction table in Unit conversions. A well-stocked jobber set is 1/16 through ½ by 64ths, plus the number and letter drills you actually use for taps.
Thread forms: Unified inch (ASME B1.1 family) and ISO metric. Tap-drill sizes are the long-standing 75% shop set. Drill diameters are the standard number and letter sizes used in U.S. practice. Torque figures are typical unlubricated starting values, not a substitute for a manufacturer’s specification or a current engineering handbook.
Electrical, wire, Ohm’s law, batteries and solar
Ohm’s law and the AWG geometry are physics. Building-wire ampacity (how many amperes you may legally put on a premises circuit) is in the National Electrical Code, which is copyrighted and is not reproduced here. Use the NEC, the listing on the breaker and the cable, and a licensed electrician for house wiring. The copper table below is diameter, area, and DC resistance, which you may use for chassis wiring, radio lead-ins, and rough voltage-drop estimates.
Ohm’s law and power
V = I R. I = V / R. R = V / I. Power: P = V I = I2 R = V2 / R. Energy in watt-hours: E = P t (hours). Series resistances add. Parallel: 1/R = 1/R1 + 1/R2 + …; two equal resistors in parallel have half the resistance. Series voltage sources add (watch polarity). Kirchhoff: the currents into a node sum to zero; the voltages around a loop sum to zero.
AC (sine, RMS): a 120 V RMS household circuit has a peak of 120 √2 ≈ 170 V. Average power into a resistive load is VRMS IRMS. Power factor and motors are a longer story — see the repair and power wings.
Resistor color code
Four-band: digit, digit, multiplier, tolerance. Five-band: digit, digit, digit, multiplier, tolerance. Example: red-violet-yellow-gold = 27 × 104 = 270 kΩ, ±5%.
| Digit | Color | Tolerance (if used as band 4/5) | Multiplier |
|---|---|---|---|
| 0 | Black | — | ×1 |
| 1 | Brown | ±1% | ×10 |
| 2 | Red | ±2% | ×100 |
| 3 | Orange | — | ×1 k |
| 4 | Yellow | — | ×10 k |
| 5 | Green | ±0.5% | ×100 k |
| 6 | Blue | ±0.25% | ×1 M |
| 7 | Violet | ±0.1% | ×10 M |
| 8 | Gray | ±0.05% | ×100 M |
| 9 | White | — | ×1 G |
| — | Gold | ±5% | ×0.1 |
| — | Silver | ±10% | ×0.01 |
| — | None (4-band) | ±20% | — |
AWG, copper, 20 °C DC resistance
Diameter formula (ASTM B258): d(inch) = 0.005 × 92(36−n)/39 for gauge n, with 1/0, 2/0, 3/0, 4/0 as n = 0, −1, −2, −3. Resistance uses 10.371 Ω·cmil/ft for annealed copper at 20 °C. Resistance rises with temperature (about 0.4% per °C for copper).
| AWG | Ø in | Ø mm | mm2 | cmil | Ω / 1,000 ft (Cu, 20 °C) |
|---|---|---|---|---|---|
| 4/0 | 0.4600 | 11.684 | 107.219 | 211600.0 | 0.0490 |
| 3/0 | 0.4096 | 10.405 | 85.029 | 167806.4 | 0.0618 |
| 2/0 | 0.3648 | 9.266 | 67.431 | 133076.5 | 0.0779 |
| 1/0 | 0.3249 | 8.251 | 53.475 | 105534.5 | 0.0983 |
| 1 | 0.2893 | 7.348 | 42.408 | 83692.7 | 0.1239 |
| 2 | 0.2576 | 6.544 | 33.631 | 66371.3 | 0.1563 |
| 3 | 0.2294 | 5.827 | 26.670 | 52634.8 | 0.1970 |
| 4 | 0.2043 | 5.189 | 21.151 | 41741.3 | 0.2485 |
| 5 | 0.1819 | 4.621 | 16.773 | 33102.4 | 0.3133 |
| 6 | 0.1620 | 4.115 | 13.302 | 26251.4 | 0.3951 |
| 7 | 0.1443 | 3.665 | 10.549 | 20818.3 | 0.4982 |
| 8 | 0.1285 | 3.264 | 8.366 | 16509.7 | 0.6282 |
| 9 | 0.1144 | 2.906 | 6.634 | 13092.7 | 0.7921 |
| 10 | 0.1019 | 2.588 | 5.261 | 10383.0 | 0.9988 |
| 11 | 0.0907 | 2.305 | 4.172 | 8234.1 | 1.2595 |
| 12 | 0.0808 | 2.053 | 3.309 | 6529.9 | 1.5882 |
| 13 | 0.0720 | 1.828 | 2.624 | 5178.5 | 2.0027 |
| 14 | 0.0641 | 1.628 | 2.081 | 4106.7 | 2.5254 |
| 15 | 0.0571 | 1.450 | 1.650 | 3256.8 | 3.1844 |
| 16 | 0.0508 | 1.291 | 1.309 | 2582.7 | 4.0155 |
| 17 | 0.0453 | 1.150 | 1.038 | 2048.2 | 5.0634 |
| 18 | 0.0403 | 1.024 | 0.823 | 1624.3 | 6.3849 |
| 19 | 0.0359 | 0.912 | 0.653 | 1288.1 | 8.0512 |
| 20 | 0.0320 | 0.812 | 0.518 | 1021.5 | 10.1524 |
| 21 | 0.0285 | 0.723 | 0.410 | 810.1 | 12.8019 |
| 22 | 0.0253 | 0.644 | 0.326 | 642.4 | 16.1429 |
| 23 | 0.0226 | 0.573 | 0.258 | 509.5 | 20.3558 |
| 24 | 0.0201 | 0.511 | 0.205 | 404.0 | 25.6682 |
| 25 | 0.0179 | 0.455 | 0.162 | 320.4 | 32.3670 |
| 26 | 0.0159 | 0.405 | 0.129 | 254.1 | 40.8141 |
| 27 | 0.0142 | 0.361 | 0.102 | 201.5 | 51.4656 |
| 28 | 0.0126 | 0.321 | 0.081 | 159.8 | 64.8969 |
| 29 | 0.0113 | 0.286 | 0.064 | 126.7 | 81.8335 |
| 30 | 0.0100 | 0.255 | 0.051 | 100.5 | 103.1901 |
| 31 | 0.0089 | 0.227 | 0.040 | 79.7 | 130.1204 |
| 32 | 0.0080 | 0.202 | 0.032 | 63.2 | 164.0788 |
| 33 | 0.0071 | 0.180 | 0.025 | 50.1 | 206.8995 |
| 34 | 0.0063 | 0.160 | 0.020 | 39.8 | 260.8954 |
| 35 | 0.0056 | 0.143 | 0.016 | 31.5 | 328.9831 |
| 36 | 0.0050 | 0.127 | 0.013 | 25.0 | 414.8400 |
| 37 | 0.0045 | 0.113 | 0.010 | 19.8 | 523.1036 |
| 38 | 0.0040 | 0.101 | 0.008 | 15.7 | 659.6214 |
| 39 | 0.0035 | 0.090 | 0.006 | 12.5 | 831.7673 |
| 40 | 0.0031 | 0.080 | 0.005 | 9.9 | 1048.8392 |
Voltage drop (DC, one-way then ×2 for the loop): V_drop = I × R, with R from the table × (feet/1000) × 2 for a go-and-return pair. A 12 V radio that draws 13 A on 20 ft of AWG 12 (round trip 40 ft) sees about 13 × (1.59 Ω/kft) × 0.040 ≈ 0.8 V drop, which is already noticeable.
Chassis-wiring current (rule of thumb, not NEC): many radio and automotive practice charts allow very roughly 10 A on AWG 18, 15–20 A on AWG 16, 20–25 A on AWG 14, 30–40 A on AWG 12, and 40–55 A on AWG 10 for short, well-cooled, chassis or vehicle runs with a fuse. These are not house-wiring numbers. Fuse for the wire, not for the load’s wishful thinking. Bundled, in-conduit, or high-ambient runs must be derated.
U.S. premises-wiring colors (informational)
Typical 120/240 V AC: black (and red, blue) are ungrounded “hot”; white or gray is grounded neutral; bare, green, or green/yellow is equipment grounding conductor. A white with colored tape in a switch loop may be hot — test, do not assume. This is a reminder of common practice, not permission to wire a house from a pocket book. The NEC is the code.
Batteries
- Lead-acid (flooded, AGM, gel): a nominal 12 V battery is about 12.6–12.8 V resting when full, about 12.0 V at roughly 50% if it has been at rest, and in the mid-11s when very low. Do not flatten a lead-acid and leave it there. Charge in a ventilated place; flooded cells give off hydrogen. Typical taper charge is around 13.8–14.4 V depending on type — use the number on the charger or the battery, not a guess.
- Capacity: ampere-hours (Ah) are usually quoted at a 20-hour rate. A 100 Ah battery is not a 100 A battery. Peukert’s effect: the faster you discharge, the fewer ampere-hours you actually get.
- Lithium-ion / LiFePO₄: use a charger and a battery-management system meant for that chemistry. Do not crush, short, or charge a swollen or wet pack. LiFePO₄ (“LFP”) 12 V packs often rest around 13.3 V full and should not be treated like lead-acid on an unadjusted automotive alternator without a proper regulator profile.
- Store batteries cool and dry. Frozen electrolyte and overheated packs both ruin capacity. Keep starting batteries for starting, deep-cycle for deep-cycle.
Solar sizing (order of magnitude)
Energy in = energy out, after losses. A starting model:
panel watts × peak sun hours × 0.7 ≈ watt-hours into the battery per day
The 0.7 is a blunt derate for heat, dirt, angle, charge-controller and wiring losses — a well-aimed, clean winter array in a valley may do worse; a cold, clean, well-aimed array may do better. Utah winter sun hours are much shorter than July. Then:
battery usable Wh ≈ battery Ah × system volts × depth-of-discharge fraction
A 12 V, 100 Ah lead-acid that you will only take to 50% gives about 600 Wh usable. A 200 W panel in 5 equivalent sun hours with a 0.7 derate gives about 700 Wh/day — enough to float that battery if the loads actually are that small. Charge-controller current ≈ panel watts / battery volts, plus margin. Use a controller sized and typed (PWM vs MPPT) for the panel’s voltage.
The IC-2730A as a worked example
The Icom IC-2730A wants a 13.8 V supply and on the order of 13 A at full 50 W transmit (see the radio’s own manual in radio/icom-ic2730a/). A fused run of short, heavy cable (AWG 10 or 8, as the manual says) from a battery or a 13.8 V, ≥ 15–20 A supply is the right kind of number; AWG 18 is not.
AWG diameter: ASTM B258 formula (NBS lineage). Copper resistivity 10.371 Ω·cmil/ft at 20 °C is the usual annealed-copper figure. NEC ampacity tables are copyrighted and omitted. Radio current: Icom IC-2730A instruction manual on this shelf (personal-use copy).
Lumber, concrete, and pipe
Dimensional lumber — nominal vs dressed (U.S. dry, typical)
| Nominal | Actual (in) | Board feet per linear foot (nominal) | Note |
|---|---|---|---|
| 1×4 | ¾ × 3½ | 0.27 / ft (nominal) | see formula |
| 1×6 | ¾ × 5½ | 0.44 / ft (nominal) | see formula |
| 1×8 | ¾ × 7¼ | 0.56 / ft (nominal) | see formula |
| 1×10 | ¾ × 9¼ | 0.72 / ft (nominal) | see formula |
| 1×12 | ¾ × 11¼ | 0.88 / ft (nominal) | see formula |
| 2×2 | 1½ × 1½ | 0.25 / ft (nominal) | see formula |
| 2×4 | 1½ × 3½ | 0.58 / ft (nominal) | see formula |
| 2×6 | 1½ × 5½ | 0.92 / ft (nominal) | see formula |
| 2×8 | 1½ × 7¼ | 1.21 / ft (nominal) | see formula |
| 2×10 | 1½ × 9¼ | 1.54 / ft (nominal) | see formula |
| 2×12 | 1½ × 11¼ | 1.88 / ft (nominal) | see formula |
| 4×4 | 3½ × 3½ | 1.36 / ft (nominal) | see formula |
| 4×6 | 3½ × 5½ | 2.15 / ft (nominal) | see formula |
| 6×6 | 5½ × 5½ | 3.36 / ft (nominal) | see formula |
Board feet = thickness (in) × width (in) × length (ft) / 12, using nominal size when you buy construction lumber. A 10-foot 2×4 is 10 × 2 × 4 / 12 ≈ 6.67 bf. What you hold is 1½ × 3½. Green or rough-sawn lumber may be closer to nominal. Hardwood is often sold surfaced (S2S/S4S) in quarter and half-inch quarters — read the sticker.
Span tables are a building-code matter. The IRC and the lumber associations publish floor, ceiling, and rafter spans. Those tables are copyrighted and are not copied here. Species, grade, spacing (12 / 16 / 19.2 / 24 in on center), live load, and dead load all change the number. A “2×8 will span a small bedroom” is folklore, not a design. Use a current span table or an engineer, especially under snow load in the Wasatch, and especially for anything people sleep under.
Old shop rules of thumb you will still hear, offered only as orientation and not as a permit: a simple joist’s span in feet is often in the neighborhood of 1.5× its nominal depth in inches for ordinary floors (a 2×10 somewhere near 15 ft), and rafters are shorter than floor joists for the same section. That rule is crude, ignores species and grade, and is wrong in a lot of real rooms. Look the span up.
Nails (common, penny system)
| Size | Length (in) | Diameter (in) typ. common | Use |
|---|---|---|---|
| 2d | 1 | 0.072 | light box |
| 4d | 1½ | 0.083 | small finish / box |
| 6d | 2 | 0.102 | common |
| 8d | 2½ | 0.131 | common; very used in framing |
| 10d | 3 | 0.148 | common |
| 12d | 3¼ | 0.148 | common |
| 16d | 3½ | 0.162 | common framing |
| 20d | 4 | 0.192 | common |
| 30d | 4½ | 0.207 | common |
| 40d | 5 | 0.225 | common |
| 60d | 6 | 0.244 | common / spike |
Concrete — volumetric field mixes
A 94 lb bag of portland cement is one cubic foot of cement as used in the old 1:2:3 talk. “Parts” below are by volume (shovels or buckets), cement : sand : coarse aggregate.
| Mix (cement:sand:stone) | Typical use | Notes |
|---|---|---|
| 1 : 2 : 3 | General purpose, sidewalks, modest footings | A very common field mix. Not a specified psi. Keep it stiff enough that it does not soup, wet enough that it consolidates. |
| 1 : 2 : 4 | Mass, less highly stressed work | Leaner. |
| 1 : 1½ : 3 | Stronger, more cement-rich work | Uses more cement per yard. |
| 1 : 3 (mortar, no stone) | Brick / block mortar is its own specification (Type N, S, M) | Do not use leftover concrete mix as if it were mortar, or leftover mortar as if it were concrete. |
- A rule of thumb: one 94 lb bag, plus sand and stone in a 1:2:3 mix, yields on the order of 4–5 ft3 of concrete, not a full ¼ yard. A cubic yard is 27 ft3. Measure the hole.
- Water: add enough to make a plastic mix you can place and consolidate. Extra water lowers strength. “A little more water so it flows into the forms” is how you get dusting and a weak slab.
- Curing matters more than most people think. Keep it moist and above freezing for at least several days (a week is better). In Utah’s dry air, cover or mist. Do not let a thin slab bake on the first day.
- Do not pour on frozen ground or let the mix freeze while it is green. Hot-weather pours need shade, a wet cure, and sometimes a cooler mix.
- Rebar numbers: #3 is ⅜ in, #4 is ½ in, #5 is ⅝ in, #6 is ¾ in (the number is eighths of an inch). Clear cover and tying are structural details — rust at the surface is how a slab tells on you later.
Pipe — steel / iron IPS, Schedule 40 and 80 (approximate ID)
| Nominal (in) | OD (in) | Sch. 40 ID (in) approx. | Sch. 80 ID (in) approx. |
|---|---|---|---|
| ⅛ | 0.405 | 0.269 | 0.215 |
| ¼ | 0.540 | 0.364 | 0.302 |
| ⅜ | 0.675 | 0.493 | 0.423 |
| ½ | 0.840 | 0.622 | 0.546 |
| ¾ | 1.050 | 0.824 | 0.742 |
| 1 | 1.315 | 1.049 | 0.957 |
| 1¼ | 1.660 | 1.380 | 1.278 |
| 1½ | 1.900 | 1.610 | 1.500 |
| 2 | 2.375 | 2.067 | 1.939 |
| 2½ | 2.875 | 2.469 | 2.323 |
| 3 | 3.500 | 3.068 | 2.900 |
| 4 | 4.500 | 4.026 | 3.826 |
Copper tube (U.S. plumbing): Type K (thickest, often buried), Type L (typical interior water), Type M (thinner, often used in light residential — check the local code). Nominal ½, ¾, 1 in copper has an OD of ⅝, ⅞, and 1⅛ in (always ⅛ in over “nominal”).
PEX: follow the manufacturer’s crimp or expansion system and the temperature/pressure rating stamped on the tube. Do not treat PEX as if it were a copper soldering job.
Lumber dressed sizes: U.S. industry standard dry dimensions (American Softwood Lumber Standard lineage). Pipe OD/ID: standard IPS / ASME B36.10 approximate bores. Concrete mixes: traditional volumetric shop practice; a specified mix design supersedes them. Span tables omitted because they are code documents.
Knots, rope, chain, and slings
A knot that cannot be untied after a load is a mistake you will pay for in the dark. Dress the knot (make the turns sit where they belong), snug it before you trust it, and leave a tail. For life support (climbing, rappel, a person in a harness) use the knots and hardware you were taught, with a backup, not a knot you just read about.
Knots worth knowing
- Bowline. A fixed loop that does not slip or jam easily. Rabbit up the hole, around the tree, back down the hole. Dress it; leave a long tail, or back it up with a stopper. Unties after a load better than most loops.
- Figure-eight follow-through / on a bight. The standard climbing tie-in and a strong, obvious loop. Bulkier than a bowline, easier to inspect.
- Square (reef) knot. Joins two ends of similar line for parcels, not for life or for a critical load. Right over left, left over right. A granny knot (same crossing both times) slips. Do not use this as a bend in rope you would miss.
- Sheet bend (and double sheet bend). Joins two ropes, including ones of different diameter — the smaller line is the working end that weaves. Double it when the sizes differ a lot or the line is slick.
- Clove hitch. Two wraps that bite on a post or a rail. Quick, adjustable, can slip on a smooth spar if it is not backed up or loaded steadily.
- Two half hitches, and the taut-line hitch. For tying a rope to a ring or a peg, and for a line you want to slide and then have hold (tent guy). The taut-line is a rolling, adjustable hitch on its own standing part.
- Trucker’s hitch. A loop (slippery figure-eight or a slipped half hitch) in the standing part, the working end through it, and a 2:1 pull to tighten a load, finished with half hitches. Excellent for lashing a tarp or a load on a rack.
- Timber hitch. A wrap with several tucks, used to drag a pole or start a diagonal lashing. Needs a continuous pull.
- Prusik. A friction hitch with a loop of smaller cord around a larger rope, used to climb or to backup. It must be the right diameter ratio and dressed neatly; a poorly tied prusik will glaze and slide.
- Stopper (figure-eight or overhand) in the tail of any knot that could work loose.
Rope — working load, not breaking load
The number on a hang-tag is often a minimum breaking strength. A working load is a fraction of that: commonly about 1/5 for a new, unused synthetic line in a straight pull (some rigging practices use 1/4 to 1/12 depending on the trade, shock load, and whether people are under it). Knots, bends, UV, mud, a sharp edge, and age all cut that down — a typical knot may cost 30–50% of the rope’s strength at the knot. There is no honest universal pound-rating in a pocket book. Read the tag; retire cut, glazed, or stiff rope; never stand under a load.
Order-of-magnitude only, for new rope, straight pull, manufacturer tag always wins: ⅜ in (10 mm) three-strand nylon often breaks in a range of several thousand pounds; ½ in more than that; polypropylene is usually weaker and floats; cheap “hardware-store” white line may be much weaker than a climbing or marine rope of the same diameter. Hemps and manilas are weaker when wet or rotten. Do not use a badly weathered line as if it were new.
Chain grades (U.S. common markings)
| Grade | Typical use | Notes |
|---|---|---|
| 30 (proof coil) | Light general, barriers | Not for overhead lifting. Often marked 3 or 30. |
| 43 (high-test) | Towing, binders, some logging | Still not a lifting chain unless the tag says so. |
| 70 (transport) | Truck tie-down, “binder chain” | Usually gold chromate. Not for overhead lifting. |
| 80 / 100 / 120 | Overhead lifting, when tagged and used with matching fittings | Only a chain that is marked and used as a lifting chain, with rated hooks and a known sling angle, is a lifting chain. |
Sling angle
When two legs of a sling share a load and the legs are not vertical, each leg sees more than half the load. Tension in each leg ≈ (Load / 2) / cos θ, or equivalently Load / (2 sin α) depending on which angle you measure — be consistent. A convenient form: if θ is the angle between the leg and the vertical, T = (W/2) / cos θ.
| Angle from vertical (each leg) | Tension in each of two legs, as a multiple of W/2 | What it feels like |
|---|---|---|
| 0° (straight up) | 1.00 × (W/2) | Best. Rare with a two-leg bridle. |
| 30° | 1.15 | Still comfortable. |
| 45° | 1.41 | Each leg sees about 70% of the whole load. |
| 60° | 2.00 | Each leg already carries the full load. |
| 75° | 3.86 | Dangerous; almost a horizontal pull on the attachments. |
A wide, flat sling angle can tear the lifting points out even when the chain is “strong enough.” Keep the included angle reasonable, use a spreader if you must, and never put a person under a suspended load.
Knot mechanics and sling-angle factors are standard statics. Chain grade uses are the usual U.S. industrial distinctions; only a tagged lifting assembly is a lifting assembly. Rope strengths vary by fiber and manufacturer and are not guaranteed here.
Fuel properties
| Fuel | lb / U.S. gal (approx.) | Btu per U.S. gal (order of magnitude) | Cautions |
|---|---|---|---|
| Gasoline (auto, approx.) | 6.3 | about 114,000–125,000 | highly flammable; vapors heavier than air; store in approved cans, away from the house |
| Diesel / #2 fuel oil | 7.1 | about 128,000–140,000 | less volatile than gasoline; still a fire and spill hazard; gels in deep cold unless winter-blended |
| Kerosene (K-1) | 6.7 | about 132,000–135,000 | heater and lamp fuel; use the grade the appliance specifies |
| Propane (LPG), liquid | 4.2 | about 91,500 | stored as a liquid under pressure; leaks down; odorant is added — a smell means get out and shut the valve if you can reach it safely |
| Ethanol (lab / fuel) | 6.6 | about 76,000 | hygroscopic; not a drop-in for every gasoline engine |
| Dry wood (seasoned, typical) | — (see weights) | about 6,000–8,000 per pound, air-dry, very species- and moisture-dependent | season before you need it; wet wood wastes heat and makes creosote |
| Charcoal (approx.) | — | about 12,000–14,000 per pound | carbon monoxide indoors can kill; never a brazier in a closed room |
These heating values are typical published higher/lower-heat ranges rounded for field use, not a laboratory certificate. A gallon of gasoline in a 20% efficient small generator yields on the order of 7–8 kWh of electricity before you count the generator’s own losses — in practice many small sets are in the 1–2 kWh per gallon neighborhood at part load. Measure your own set if you depend on it.
Store fuel in approved containers, labeled, away from living spaces and ignition, and with a plan for spills. Rotating gasoline (and using stabilizer) matters; old gas varnishes small engines. Diesel lasts longer but grows bugs and takes up water. Propane does not go stale, but fittings, hoses, and regulators do.
Densities and heating values: typical figures consistent with NIST / DOE / EIA public ranges and older Smithsonian physical tables. Use a current SDS and the appliance manual for anything you burn indoors.
Weights of materials
| Material | lb / ft3 | kg / m3 | Note |
|---|---|---|---|
| Water, 4 °C / 39 °F | 62.4 | 1000 | 8.34 lb/U.S. gal at ~60 °F is the usual shop figure |
| Ice | 57.2 | 917 | floats; volume expands ~9% from water |
| Snow, loose / settled (very rough) | 5–25 | 80–400 | varies wildly; do not size a roof from this |
| Steel (mild, average) | 490 | 7850 | 0.283 lb/in3; 40.8 lb/ft2 per inch thick |
| Cast iron | 450 | 7200 | approx. |
| Aluminum | 169 | 2700 | about 1/3 of steel |
| Copper | 559 | 8960 | bus bars, tubing, windings |
| Brass (typical) | 530 | 8500 | alloy-dependent |
| Lead | 708 | 11340 | dense; toxic dust — do not grind casually |
| Concrete (plain, cured, typ.) | 145–150 | 2300–2400 | reinforced is heavier |
| Brick, masonry (typical) | 120 | 1900 | varies |
| Sand, dry / wet (bulk) | 90–110 / 110–130 | 1450–2100 | bulk, not solid quartz |
| Gravel, loose | 90–120 | 1500–1900 | bulk |
| Portland cement (bulk) | 90–94 | 1440–1500 | a bag is 94 lb |
| Softwood, dry (pine, typ.) | 25–35 | 400–560 | species and moisture dominate |
| Hardwood, dry (oak, typ.) | 40–50 | 640–800 | white oak is toward the high end |
| Gasoline | 45–47 | 720–750 | see Fuel |
| Diesel | 51–53 | 820–850 | |
| Propane, liquid | 31–32 | 500–510 | at ordinary tank temperature, approximate |
| Air, dry, 0 °C, 1 atm | 0.0807 | 1.2929 | 1.225 kg/m3 at 15 °C is a common figure |
| Earth, average packed (very rough) | 75–125 | 1200–2000 | do not design a retaining wall from this |
Steel plate weight (lb) ≈ 0.283 × thickness (in) × width (in) × length (in). A 4 ft × 8 ft sheet of ¼ in steel is about 327 lb. A 4×8 of ¾ in plywood is often 50–70 lb depending on grade; a 4×8 of ½ in drywall is about 50–55 lb.
Densities are typical handbook values (Smithsonian Physical Tables 7th ed. 1921 is on this shelf in reference/, with more modern typical construction figures). Alloys, moisture, and compaction move the number.
Water purification doses
The figures in this section are copied from EPA 816-F-15-003, Emergency Disinfection of Drinking Water, September 2017, which is already in this archive at food-water/water-purification/EPA_Emergency_Disinfection_of_Drinking_Water_Sept2017.pdf. Boiling or disinfection kills many disease-causing microorganisms. It does not remove heavy metals, salts, or most chemicals. Use only water that has been properly disinfected for drinking, cooking, prepared drinks, washing dishes, and brushing teeth.
Boil (preferred when you can)
- If the water is cloudy, let it settle and filter it through a clean cloth, paper towel, or coffee filter.
- Bring it to a rolling boil for at least one minute. At altitudes above 5,000 feet (1,500 meters), boil for three minutes. Much of the Wasatch Front’s higher towns and almost all of the ski-canyon settlements sit above that line; Salt Lake Valley itself is below it, but do not guess — if you are near 5,000 feet, use the three-minute time.
- Let it cool naturally. Store it in clean, covered containers.
- To improve the flat taste, add a pinch of salt to each quart or liter, or pour from one clean container into another several times.
Household bleach (when you cannot boil)
Use only regular, unscented chlorine bleach that is suitable for disinfection, with 6 or 8.25% sodium hypochlorite on the label. Do not use scented, color-safe, or bleaches with added cleaners. Use a fresh bottle stored at room temperature for less than one year. If the water is cloudy, let it settle and filter it first. Double the amount of bleach if the water is cloudy, colored, or very cold.
| Volume of water | 6% bleach | 8.25% bleach |
|---|---|---|
| 1 quart / 1 liter | 2 drops | 2 drops |
| 1 gallon | 8 drops | 6 drops |
| 2 gallons | 16 drops (¼ tsp) | 12 drops (⅛ tsp) |
| 4 gallons | ⅓ tsp | ¼ tsp |
| 8 gallons | ⅔ tsp | ½ tsp |
Other EPA methods (summary)
- Granular calcium hypochlorite (HTH): in a ventilated place with eye protection, dissolve one heaping teaspoon (about ¼ ounce) of high-test granular calcium hypochlorite in two gallons of water to make an approximately 500 mg/L chlorine solution. Add one part of that solution to 100 parts of the water you are treating (about 1 pint of solution to 12.5 gallons of water). HTH is a strong oxidizer — follow the label. See the EPA leaflet for the exact wording.
- 2% tincture of iodine: EPA’s leaflet says you may add five drops to each quart or liter. Iodine is not for everyone (thyroid, pregnancy, some sensitivities, and it is not the first choice for long use). Read the EPA pages and a clinician’s advice; this line is a pointer, not a standing order.
Filters, UV pens, and chlorine-dioxide tablets have their own official directions and pore-size or log-reduction claims. A filter that does not say it handles cysts is not a giardia plan. Cloudy water should be prefiltered.
U.S. EPA, Office of Water, EPA 816-F-15-003, September 2017. Altitude rule is EPA’s (1 minute; 3 minutes above 5,000 feet). Ready.gov also discusses storing an emergency water supply (about one gallon per person per day is the usual planning figure).
Food storage and calories
A planning calorie is not a diet. Sedentary adults often sit near 1,800–2,400 kcal/day; cold, wet, hard labor can want much more. Children, pregnant people, and the ill have their own needs — use the USDA and medical manuals, not a guess, when it matters. Protein, fat, salt, and micronutrients (especially vitamin C, and iodine if you are far from iodized salt or seafood) catch up with a starch-only pile of rice.
Approximate energy of staples
| Food | Amount | kcal (approx.) | Note |
|---|---|---|---|
| White rice, raw | 100 g | 360–365 | about 1,600–1,700 per dry pound; cooked is mostly water |
| Brown rice, raw | 100 g | 360–370 | |
| Wheat flour, all-purpose | 100 g | 360–365 | a cup of floured AP is often ~120 g, not 100 |
| Dry beans, typical | 100 g | 330–350 | must be fully cooked; raw red kidney beans are toxic |
| Rolled oats | 100 g | 380–390 | |
| Pasta, dry | 100 g | 360–370 | |
| White sugar | 100 g | 387 | 4 kcal/g carbohydrate |
| Honey | 100 g | 300–305 | not for infants under 1 year |
| Vegetable oil | 100 g / 1 Tbsp (~14 g) | 884 / ~120 | 9 kcal/g fat |
| Butter | 100 g / 1 Tbsp | 717 / ~100 | |
| Peanut butter | 100 g | 590–600 | check the jar; salt and sugar vary |
| Almonds, dry | 100 g | 575–580 | |
| Powdered milk, nonfat | 100 g | 350–360 | reconstitute per the bag |
| Cheddar cheese | 100 g | 400–410 | needs cool storage once opened |
| Canned tuna, in water, drained | 100 g | 85–130 | protein staple |
| Canned salmon | 100 g | 130–170 | |
| Canned corn, drained | 100 g | 60–80 | |
| Potato, raw | 100 g | 70–80 | |
| Eggs, whole, raw | 1 large (~50 g) | ~70–80 | cook thoroughly |
| Chicken, cooked meat, typical | 100 g | 160–190 | |
| Lean beef, cooked, typical | 100 g | 170–250 | fat changes this a lot |
| Hard candy / glucose | 100 g | ~380–400 | a useful but empty calorie |
| Dark chocolate, typical | 100 g | 500–600 | |
| Water | any | 0 | you still need it — calories are not hydration |
Macronutrient rule of thumb: carbohydrate and protein ≈ 4 kcal/g, fat ≈ 9 kcal/g, alcohol ≈ 7 kcal/g (not a recommendation). A cup is a volume, not a weight — a cup of cooked rice is not a cup of dry rice.
Storage, quality, and safety
| Item | Typical quality window (cool, dry, dark) | Safety notes |
|---|---|---|
| Canned goods, high-acid (tomato, fruit, pickles) | Quality often best within 12–18 months | A sound, unbulged, unrusted can may last longer; discard bulging, spurting, or badly rusted cans. Never taste to “check” a suspect can. |
| Canned goods, low-acid (meat, vegetables, soups, beans) | Quality often best within 2–5 years if cool and dry | Botulism is the reason you do not eat from a bulged or leaking low-acid can, and the reason home canning of low-acid food must follow a tested pressure-canning process. See the Pantry wing and USDA/USU publications. |
| White rice, dry beans, dry pasta, sugar, salt — sealed, cool, dry, pest-proof | Years, if kept dry and away from insects and mice | Brown rice and whole-wheat flour go rancid sooner because of the oil in the bran. Rotate them faster. |
| Flour, opened oils, nuts, whole grains | Months, not years, at room temperature | Cool and dark helps. Rancid oil smells like crayons or putty — do not use it as if it were fresh. |
| Powdered milk, unopened | Often a year or more at cool room temperature; longer if kept truly cool and dry | Follow the bag. Once opened, keep dry and rotate. |
| MREs and similar pouches | Follow the date and storage temperature on the case | Heat shortens life dramatically. |
| Honey, sugar, salt, distilled spirits | Indefinite as foods if kept clean and dry (honey may crystallize — that is not spoilage) | Honey is not for infants under one year. |
| Water in food-grade containers, stored in the dark | Rotate every 6–12 months if you have no official long-life packaging | One gallon per person per day is the usual planning figure (drinking and hygiene). |
Home canning: only a current, tested recipe from USDA or a land-grant extension (USU in Utah) is a canning recipe. An electric pressure cooker is not a pressure canner unless the official publication you are following says that exact model may be used that way. See the Personal Shelf / Utah Local extension notes in this archive.
Calorie figures: typical USDA FoodData Central values, rounded for field use. Storage windows: USDA / FoodSafety.gov style quality guidance, plus standard emergency-planning practice (Ready.gov water). Botulism and low-acid canning rules: USDA Complete Guide to Home Canning, in the pantry materials.
First-aid quick charts
This is a reminder sheet, not a course and not a diagnosis. The controlling manuals on this shelf are FM 4-25.11 First Aid, ATP 3-50.21, and the Hesperian Where There Is No Doctor (especially the first-aid chapters and the green pages). Get trained (Stop the Bleed, CPR) while you still can. For a medical emergency, use real medical help when it exists.
Scene, blood, breathing
- Do not become the second casualty. Look for traffic, fire, wires, gas, a still-armed attacker, or a collapsed trench before you step in.
- Life-threatening bleeding first when it is obviously that: apply firm direct pressure with a cloth; pack a deep wound if you were taught to; a tourniquet high and tight on a limb for life-threatening extremity bleeding if you were taught and pressure is not enough. Note the time. Do not take a tourniquet off as an experiment.
- Airway and breathing: talk to the person. If they cannot protect an airway, use the positioning and airway maneuvers you were trained in (and consider a possible neck injury). Recovery position if they are unresponsive but breathing and you must leave the airway unattended.
- If they are not breathing normally and you are trained, start CPR. Current public layperson emphasis is chest compressions in the center of the chest, hard and fast, about 100–120 per minute, allowing full recoil, in adults; trained rescuers may add breaths in a 30:2 ratio. An AED, if you have one, is used as soon as it is available. Get a current class — this paragraph is a memory aid for people who already had one.
Shock, burns, bone, cold, heat
- Shock (pale, sweaty, confused, weak pulse after bleeding, burns, or trauma): lie the person down, keep them warm, stop the bleeding, do not give food or drink if surgery or an unprotected airway is likely, and get help.
- Burns: cool with cool running water (not ice) for some minutes. Remove tight things from the area before swelling. Cover loosely with a clean, dry cloth. Do not put butter, toothpaste, or grease on a burn. Electrical and large or deep burns, burns of the face, hands, feet, or groin, and burns in children are not “wait and see” injuries.
- Suspected fracture: splint in the position found if you must move the person and you were taught how; pad well; check fingers or toes for color and feeling before and after. An open fracture is a wound plus a bone problem — cover, do not push bone back, get help.
- Hypothermia: wet and windy Utah nights will do this even when the afternoon was mild. Get them out of the wind, replace wet clothes, insulate from the ground, warm the trunk, give sweet drinks only if they are fully awake and can swallow. Not a hot bath for a barely-conscious person, and not rubbing frozen feet hard.
- Heat illness: move to shade, loosen clothes, cool with water and air. Heat stroke (confused, very hot, may have stopped sweating) is an emergency — aggressive cooling and help, not “sleep it off.”
- Bite and sting: see the Dangerous Animals and Insects page in the Edible Plants guide, and the medical manuals. For a possible rattlesnake bite: keep the person calm and still, take off rings before swelling, get them to care; do not cut, suck, or pack the limb in ice as a folk cure.
Choking, opioid overdose (naloxone when you have it and were taught), childbirth, and mental-health crisis all have their own chapters in the manuals above. Do not invent a procedure from a one-line reminder.
Orientation only. See FM 4-25.11, ATP 3-50.21, Hesperian Where There Is No Doctor, and a current Stop the Bleed / CPR class. Compression rate 100–120/min is the widely published AHA figure; take a class for the current algorithm.
Medication dosing — official principles only
This archive will not invent a formulary. Doses for prescription drugs, and most pediatric doses, belong on the label, in a current official monograph, or in a manual that was written as one (the Hesperian green pages, a military or WHO formulary you actually have). A number remembered wrong is a poisoned patient.
- Read the label that is on the package in your hand, including the warnings, the active ingredient, and the age or weight limits. Two products with similar brand names may not be the same drug.
- Do not give adult products to children unless the label or a clinician says that exact product may be used that way. Liquid children’s medicines are measured with the device that came with them, not a kitchen teaspoon (a “teaspoon” is not reliably 5 mL).
- Weight-based dosing (mg/kg) is a clinical calculation. If you are not following a written official dose, do not invent one.
- “More” is not better. Acetaminophen (paracetamol) in particular has a hard ceiling; doubling it does not double the relief and can wreck a liver. Combination cold products often already contain acetaminophen — add the ingredients, not just the brand names.
- Expiration: a date is a quality promise from the maker, not always an instantaneous loss of effect, but it is also not a reason to take a degraded or badly stored drug and hope. Liquids, insulin, reconstituted antibiotics, and anything that changed color, smell, or form are not “probably fine.” When you still have a pharmacy, rotate the kit.
- Pregnancy, breastfeeding, liver and kidney disease, asthma, ulcers, blood thinners, and other drugs already in the person all change what is safe. A book on a shelf cannot see those.
- Storage: cool, dry, dark, out of children’s reach, in the original labeled container when you can. A car in a Utah summer is not a medicine cabinet.
Oral rehydration (pointer)
Dehydration from diarrhea is treated first with fluids. WHO publishes an official reduced-osmolarity ORS formula and, as a temporary household measure when the packets are gone, a sugar-and-salt drink with strict amounts. Use the official WHO or CDC wording if you must mix it, and do not “make it saltier so it works faster.” The Hesperian books and the medical wing carry the directions. This paragraph is a pointer to those sources, not a recipe invented here.
Principles only. Hesperian green pages, FM 4-25.11, WHO / CDC oral-rehydration publications, and the label on the product you actually have are the places to read a dose.
Weather and wind
Beaufort wind scale
| Force | Name | mph (mean, approx.) | m/s | Land signs |
|---|---|---|---|---|
| 0 | Calm | 0–1 | 0–0.2 | Smoke rises straight. |
| 1 | Light air | 1–3 | 0.3–1.5 | Smoke drifts. |
| 2 | Light breeze | 4–7 | 1.6–3.3 | Leaves rustle; face feels wind. |
| 3 | Gentle breeze | 8–12 | 3.4–5.4 | Leaves and small twigs move. |
| 4 | Moderate breeze | 13–18 | 5.5–7.9 | Small branches move; dust and loose paper. |
| 5 | Fresh breeze | 19–24 | 8.0–10.7 | Small trees sway. |
| 6 | Strong breeze | 25–31 | 10.8–13.8 | Large branches; whistling wires; umbrellas hard to use. |
| 7 | Near gale | 32–38 | 13.9–17.1 | Whole trees; inconvenience walking against it. |
| 8 | Gale | 39–46 | 17.2–20.7 | Twigs break; walking is hindered. |
| 9 | Strong gale | 47–54 | 20.8–24.4 | Slight structural damage possible. |
| 10 | Storm | 55–63 | 24.5–28.4 | Trees uprooted; considerable damage. |
| 11 | Violent storm | 64–72 | 28.5–32.6 | Widespread damage. |
| 12 | Hurricane | 73+ | 32.7+ | Extreme; rarely inland at this force except in a true hurricane or a violent tornado outflow. |
Saffir–Simpson hurricane wind scale (NWS/NHC)
| Category | Sustained winds | Damage (very brief) |
|---|---|---|
| 1 | 74–95 mph (64–82 kt) | Some damage to roofs, shingles, trees, power lines. |
| 2 | 96–110 mph | Major roof and tree damage; likely power outages. |
| 3 (major) | 111–129 mph | Devastating: well-built homes can lose roof deck; electricity and water may be out for days to weeks. |
| 4 (major) | 130–156 mph | Catastrophic structural damage; area uninhabitable for weeks to months. |
| 5 (major) | 157 mph or higher | Catastrophic; a high percentage of framed homes destroyed. |
Utah is not a hurricane coast, but the scale is useful if you ever have to read a national forecast, and a severe thunderstorm or a canyon downslope wind can still reach gale and storm force on the Beaufort scale. Lightning: if the time from flash to thunder is 30 seconds or less (about 6 miles), you are in range; get off ridges and put down long conductors. The “30–30” memory aid is: 30 seconds to take shelter, then wait 30 minutes after the last thunder.
Wind chill and heat index are NWS products. They are not the same as the thermometer. In a dry Utah winter, wind on bare skin will frostbite faster than the temperature alone suggests; in a dry summer, a 100 °F afternoon plus direct sun and no water is a heat-illness problem even when the “humidity is low.” See NWS charts if you have them, and the first-aid section.
Winter storms, avalanche, and flash flood in slot canyons and burn scars are the local killers more often than hurricanes. A weather radio (SAME / NOAA) and a glance at the sky still earn their keep.
Beaufort equivalents: standard modern meteorological presentation of a 19th-century public scale. Saffir–Simpson: U.S. National Hurricane Center / NWS, public. Lightning 30–30: widely published NWS public-safety guidance.
Radio band plans, Morse, and phonetics
A Technician-class amateur station Technician has full amateur privileges on 2 meters (144–148 MHz) and 70 centimeters (420–450 MHz) in the U.S. See the radio quick references and 47 CFR Part 97 in this demo's radio wing. Regional repeater lists are in the full edition. The next exam pool to study is General (2023–2027 pool, through 30 June 2027).
Everyday VHF/UHF frequencies (U.S. amateur)
- National 2 m FM calling: 146.52 MHz. National 70 cm FM calling: 446.00 MHz. Make the call, then move off if you are going to chat.
- Repeater offsets: 2 m is usually ±0.600 MHz (a 146.76 output is commonly a 146.16 input). 70 cm offset is usually +5 MHz in this part of the country, but not always — use a current official repeater directory, not a guess.
- Simplex, calling, and repeater segments are customary, not all of them hard-coded in Part 97. Do not transmit in the radio-astronomy or weak-signal corners out of courtesy, and never outside an allocation you have a privilege for.
- Part 97 identification: give your call sign at the end of the communication and at least every 10 minutes during a long one (97.119). Cross-band on the IC-2730A is legal for a Technician on 2 m/70 cm if you remain a control operator and identify on both frequencies; see the IC-2730A quick reference. Automatic-control tricks that skip those duties are not in this book.
Wavelength (approximate): λ (m) ≈ 300 / f (MHz). 146 MHz is about 2 m; 446 MHz is about 0.67 m. A quarter-wave on 2 m is about 19 inches (49 cm); on 70 cm about 6.3 inches (16 cm), before you account for velocity factor and how the antenna is built.
ICAO / ITU phonetic alphabet
| Letter | Word | Letter | Word |
|---|---|---|---|
| A | Alfa | N | November |
| B | Bravo | O | Oscar |
| C | Charlie | P | Papa |
| D | Delta | Q | Quebec |
| E | Echo | R | Romeo |
| F | Foxtrot | S | Sierra |
| G | Golf | T | Tango |
| H | Hotel | U | Uniform |
| I | India | V | Victor |
| J | Juliett | W | Whiskey |
| K | Kilo | X | X-ray |
| L | Lima | Y | Yankee |
| M | Mike | Z | Zulu |
Figures are spoken as “tree,” “fife,” and “niner” in some aviation and traffic-handling practice (3, 5, 9) to survive a bad circuit. Amateur practice varies; be clear, not cute.
International Morse (ITU)
| Ch | Code | Ch | Code | Ch | Code |
|---|---|---|---|---|---|
| A | .- | N | -. | 1 | .---- |
| B | -... | O | --- | 2 | ..--- |
| C | -.-. | P | .--. | 3 | ...-- |
| D | -.. | Q | --.- | 4 | ....- |
| E | . | R | .-. | 5 | ..... |
| F | ..-. | S | ... | 6 | -.... |
| G | --. | T | - | 7 | --... |
| H | .... | U | ..- | 8 | ---.. |
| I | .. | V | ...- | 9 | ----. |
| J | .--- | W | .-- | 0 | ----- |
| K | -.- | X | -..- | . | .-.-.- |
| L | .-.. | Y | -.-- | , | --..-- |
| M | -- | Z | --.. | ? | ..--.. |
| / | -..-. | + | .-.-. | = | -...- |
| SOS | ...---... | wait (AS) | .-... | break (BT) | -...- |
| end (AR) | .-.-. | out (SK) | ...-.- | error | ........ |
Timing: a dash is three dots; space between elements of a letter is one dot; between letters three; between words seven. SOS is a single prosign, not three letters with letter-spacing. Learn it by sound, not by looking at dots on a page, if you actually want to copy it.
Common Q-signals
| Code | Usual meaning in amateur work |
|---|---|
| QTH | Location (my QTH is … / what is your QTH?) |
| QSY | Change frequency |
| QRZ | Who is calling me? |
| QRM | Man-made interference |
| QRN | Static / natural noise |
| QSB | Fading |
| QSO | A contact |
| QSL | Acknowledge / confirmation |
| QRP | Low power |
| QRO | High power |
| QRX | Wait |
| QRV | I am ready |
| QRT | I am stopping (going off the air) |
| QRS | Send more slowly |
| QLF | not official; ignore folklore |
CTCSS (PL) tones, Hz
| 67.0 | 69.3 | 71.9 | 74.4 | 77.0 | 79.7 | 82.5 | 85.4 |
| 88.5 | 91.5 | 94.8 | 97.4 | 100.0 | 103.5 | 107.2 | 110.9 |
| 114.8 | 118.8 | 123.0 | 127.3 | 131.8 | 136.5 | 141.3 | 146.2 |
| 151.4 | 156.7 | 159.8 | 162.2 | 165.5 | 167.9 | 171.3 | 173.8 |
| 177.3 | 179.9 | 183.5 | 186.2 | 189.9 | 192.8 | 196.6 | 199.5 |
| 203.5 | 206.5 | 210.7 | 218.1 | 225.7 | 229.1 | 233.6 | 241.8 |
| 250.3 | 254.1 |
RST: readability 1–5, strength 1–9, tone 1–9 (CW). “59” is the lazy signal report; use a real one when it would help the other station.
Morse and phonetics: ITU / ICAO public alphabets. Band facts: 47 CFR Part 97 and long-standing U.S. calling-frequency custom. CTCSS tone frequencies: standard EIA set.
Periodic table
Atomic numbers 1–118 with a conventional standard atomic weight (IUPAC). Values in brackets are the mass number of the longest-lived isotope of a radioelement that has no stable isotope. Use NIST or IUPAC if you need more figures than a pocket table.
| Z | Symbol | Name | Atomic weight |
|---|---|---|---|
| 1 | H | Hydrogen | 1.008 |
| 2 | He | Helium | 4.0026 |
| 3 | Li | Lithium | 6.94 |
| 4 | Be | Beryllium | 9.0122 |
| 5 | B | Boron | 10.81 |
| 6 | C | Carbon | 12.011 |
| 7 | N | Nitrogen | 14.007 |
| 8 | O | Oxygen | 15.999 |
| 9 | F | Fluorine | 18.998 |
| 10 | Ne | Neon | 20.180 |
| 11 | Na | Sodium | 22.990 |
| 12 | Mg | Magnesium | 24.305 |
| 13 | Al | Aluminium | 26.982 |
| 14 | Si | Silicon | 28.085 |
| 15 | P | Phosphorus | 30.974 |
| 16 | S | Sulfur | 32.06 |
| 17 | Cl | Chlorine | 35.45 |
| 18 | Ar | Argon | 39.95 |
| 19 | K | Potassium | 39.098 |
| 20 | Ca | Calcium | 40.078 |
| 21 | Sc | Scandium | 44.956 |
| 22 | Ti | Titanium | 47.867 |
| 23 | V | Vanadium | 50.942 |
| 24 | Cr | Chromium | 51.996 |
| 25 | Mn | Manganese | 54.938 |
| 26 | Fe | Iron | 55.845 |
| 27 | Co | Cobalt | 58.933 |
| 28 | Ni | Nickel | 58.693 |
| 29 | Cu | Copper | 63.546 |
| 30 | Zn | Zinc | 65.38 |
| 31 | Ga | Gallium | 69.723 |
| 32 | Ge | Germanium | 72.630 |
| 33 | As | Arsenic | 74.922 |
| 34 | Se | Selenium | 78.971 |
| 35 | Br | Bromine | 79.904 |
| 36 | Kr | Krypton | 83.798 |
| 37 | Rb | Rubidium | 85.468 |
| 38 | Sr | Strontium | 87.62 |
| 39 | Y | Yttrium | 88.906 |
| 40 | Zr | Zirconium | 91.224 |
| 41 | Nb | Niobium | 92.906 |
| 42 | Mo | Molybdenum | 95.95 |
| 43 | Tc | Technetium | [98] |
| 44 | Ru | Ruthenium | 101.07 |
| 45 | Rh | Rhodium | 102.91 |
| 46 | Pd | Palladium | 106.42 |
| 47 | Ag | Silver | 107.87 |
| 48 | Cd | Cadmium | 112.41 |
| 49 | In | Indium | 114.82 |
| 50 | Sn | Tin | 118.71 |
| 51 | Sb | Antimony | 121.76 |
| 52 | Te | Tellurium | 127.60 |
| 53 | I | Iodine | 126.90 |
| 54 | Xe | Xenon | 131.29 |
| 55 | Cs | Caesium | 132.91 |
| 56 | Ba | Barium | 137.33 |
| 57 | La | Lanthanum | 138.91 |
| 58 | Ce | Cerium | 140.12 |
| 59 | Pr | Praseodymium | 140.91 |
| 60 | Nd | Neodymium | 144.24 |
| 61 | Pm | Promethium | [145] |
| 62 | Sm | Samarium | 150.36 |
| 63 | Eu | Europium | 151.96 |
| 64 | Gd | Gadolinium | 157.25 |
| 65 | Tb | Terbium | 158.93 |
| 66 | Dy | Dysprosium | 162.50 |
| 67 | Ho | Holmium | 164.93 |
| 68 | Er | Erbium | 167.26 |
| 69 | Tm | Thulium | 168.93 |
| 70 | Yb | Ytterbium | 173.05 |
| 71 | Lu | Lutetium | 174.97 |
| 72 | Hf | Hafnium | 178.49 |
| 73 | Ta | Tantalum | 180.95 |
| 74 | W | Tungsten | 183.84 |
| 75 | Re | Rhenium | 186.21 |
| 76 | Os | Osmium | 190.23 |
| 77 | Ir | Iridium | 192.22 |
| 78 | Pt | Platinum | 195.08 |
| 79 | Au | Gold | 196.97 |
| 80 | Hg | Mercury | 200.59 |
| 81 | Tl | Thallium | 204.38 |
| 82 | Pb | Lead | 207.2 |
| 83 | Bi | Bismuth | 208.98 |
| 84 | Po | Polonium | [209] |
| 85 | At | Astatine | [210] |
| 86 | Rn | Radon | [222] |
| 87 | Fr | Francium | [223] |
| 88 | Ra | Radium | [226] |
| 89 | Ac | Actinium | [227] |
| 90 | Th | Thorium | 232.04 |
| 91 | Pa | Protactinium | 231.04 |
| 92 | U | Uranium | 238.03 |
| 93 | Np | Neptunium | [237] |
| 94 | Pu | Plutonium | [244] |
| 95 | Am | Americium | [243] |
| 96 | Cm | Curium | [247] |
| 97 | Bk | Berkelium | [247] |
| 98 | Cf | Californium | [251] |
| 99 | Es | Einsteinium | [252] |
| 100 | Fm | Fermium | [257] |
| 101 | Md | Mendelevium | [258] |
| 102 | No | Nobelium | [259] |
| 103 | Lr | Lawrencium | [266] |
| 104 | Rf | Rutherfordium | [267] |
| 105 | Db | Dubnium | [268] |
| 106 | Sg | Seaborgium | [269] |
| 107 | Bh | Bohrium | [270] |
| 108 | Hs | Hassium | [277] |
| 109 | Mt | Meitnerium | [278] |
| 110 | Ds | Darmstadtium | [281] |
| 111 | Rg | Roentgenium | [282] |
| 112 | Cn | Copernicium | [285] |
| 113 | Nh | Nihonium | [286] |
| 114 | Fl | Flerovium | [289] |
| 115 | Mc | Moscovium | [290] |
| 116 | Lv | Livermorium | [293] |
| 117 | Ts | Tennessine | [294] |
| 118 | Og | Oganesson | [294] |
Groups (vertical, IUPAC 1–18): 1 alkali metals (Li, Na, K, Rb, Cs, Fr), 2 alkaline earths, 17 halogens (F, Cl, Br, I, At, Ts), 18 noble gases. Periods are the rows. Lanthanoids 57–71 and actinoids 89–103 sit under the table in the usual display.
Common oxidation / valency reminders, not a chemistry course: H 1; O usually 2; Na 1; Ca 2; Al 3; C 4; Cl 1 (or more); Fe 2 or 3; Cu 1 or 2; N 3 or 5 in many compounds. Water is H2O; air is mostly N2 and O2.
Weights: IUPAC Standard Atomic Weights (conventional), as also used in NIST listings. Bracketed mass numbers are the usual handbook convention for radioelements.
Welding rods, torque reminders, and tire codes
SMAW (stick) electrode classification, very brief
An AWS E7018-style number: E electrode, 70 × 1,000 psi minimum tensile (70 ksi), 1 means all-position in the usual system, 8 is the coating and current type (low-hydrogen, iron-powder). E60xx is a 60 ksi class. The letters after a dash (A1, H4R, and so on) are extras. This is a memory aid, not a welding procedure specification.
| Electrode | Current (typical) | Arc / slag | Use and cautions |
|---|---|---|---|
| E6010 | DC+ | Deep, digging, a tight arc | Pipe, dirty or painted steel, root passes. Fast-freeze. Not the beginner’s first rod. |
| E6011 | AC or DC+ | Similar to 6010, runs on AC | Farm and field work when you only have an AC “buzz box.” |
| E6013 | AC or DC | Softer, easy slag, modest penetration | Sheet, general repair, learners. Pretty beads, less muscle. |
| E7018 | DC+ (and some AC 7018A1 etc.) | Low-hydrogen, strong, smooth | Structural steel when the procedure calls for it. Keep the rods dry — a rod oven or a sealed can. Damp 7018 is how you get hydrogen cracks. |
| E7024 | AC or DC | Iron-powder, high deposition, flat and horizontal | Fillet welds where you can go fast on a flat joint. |
Polarity: DC+ (reverse) puts more heat in the work for many electrodes; DC− (straight) puts more heat in the rod. AC is what a cheap transformer welder gives you. Clean the joint, ventilate (zinc, cadmium, and galvanized fumes are not a joke), and do not weld on a closed tank or a container that has held fuel.
Helmet shade (order of magnitude)
| Process / current | Shade (typical starting point) | Note |
|---|---|---|
| Cutting, light / plasma (follow the machine) | often 5–8 | The label on the goggles or the helmet wins. |
| SMAW (stick) under ~60 A, thin work | 9–10 | Too dark and you cannot see the puddle; too light and you burn your eyes. |
| SMAW ~60–160 A | 10–12 | Common farm-and-shop range. |
| SMAW ~160–250 A / heavier | 12–14 | |
| GMAW / FCAW similar currents | similar to SMAW | Auto-darkening helmets must still have a shade that is dark enough at the current you run. |
| GTAW (TIG) lower current | often 9–12 | A gas-lens and a tight hood help you see. |
Torque, again
The Grade 5 / Grade 8 table lives in the Fasteners section. Lug nuts, axle nuts, head bolts, and anything a shop manual lists are not in that table on purpose. Use a torque wrench that was calibrated sometime this decade, in the middle of its scale, with the socket fully seated. A click wrench left stored compressed, or used as a breaker bar, is a random-number generator.
Tire codes
A typical sidewall: P215/65R16 95H.
- P (optional) is a P-metric passenger tire. LT is a light-truck tire with a different load rule. A tire with no P and a service description may be a Euro-metric passenger tire — load can differ slightly from a P-metric of the same size.
- 215 is the section width in millimetres. 65 is the aspect ratio: sidewall height is 65% of the section width. R is radial construction. 16 is the wheel diameter in inches.
- 95 is a load index (look it up on a load table — 95 is 690 kg as a single, for example; do not guess a towing load from the number alone). H is a speed symbol (H is 210 km/h / 130 mph). You need the load more often than the speed.
- Date code: a four-digit DOT week/year near the end of the DOT serial, for example
2319is the 23rd week of 2019. Older three-digit codes are from before 2000. A ten-year-old spare is a decision, not a decoration — rubber ages even if the tread looks fine. - The pressure you air to is the number on the vehicle placard (door jamb or glove box), not the “max press” on the sidewall. The sidewall max is a limit, not a recommendation. Check cold.
- A T125/80R16 or similar is often a temporary spare (“donut”) with its own speed and distance limit on the sidewall. It is not a highway tire for a road trip.
Electrode classification: AWS A5.1-style numbering, described in words. Helmet shades: typical AWS user-guide ranges, not a substitute for the current standard or the helmet’s label. Tire codes: U.S. DOT / tire-industry sidewall conventions, public.
Cooking measures and substitutions
| Amount | Equals | Also | Metric / note |
|---|---|---|---|
| 1 Tbsp | 3 tsp | ½ fl oz | 15 mL (approx.) |
| 1 fl oz (U.S.) | 2 Tbsp | 6 tsp | 29.57 mL |
| ¼ cup | 4 Tbsp | 2 fl oz | 59 mL |
| ⅓ cup | 5 Tbsp + 1 tsp | 2⅔ fl oz | 79 mL |
| ½ cup | 8 Tbsp | 4 fl oz | 118 mL |
| 1 cup | 16 Tbsp | 8 fl oz | 237 mL (nutrition labels often use 240 mL) |
| 1 pint | 2 cups | 16 fl oz | 473 mL |
| 1 quart | 2 pints / 4 cups | 32 fl oz | 946 mL |
| 1 gallon | 4 quarts | 128 fl oz | 3.785 L |
| 1 stick of U.S. butter | ½ cup / 8 Tbsp | 4 oz (113 g) | the wrapper is usually marked in Tbsp |
| 1 lb butter | 2 cups / 4 sticks | 454 g | |
| 1 lb all-purpose flour (approx.) | about 3½ cups spooned | varies with packing | weigh if it matters |
| 1 lb granulated sugar | about 2¼ cups | 454 g | |
| 1 lb brown sugar, packed | about 2¼ cups | ||
| 1 lb powdered sugar, unsifted | about 3¾–4 cups | ||
| 1 cup dry rice | about 3 cups cooked | varies | brown rice and pilaf methods differ |
| 1 cup dry beans | about 2–3 cups cooked | soak and cook thoroughly | |
| 1 cup uncooked pasta, small shapes | varies widely | use the bag’s yield |
Common substitutions
| If you need | You can sometimes use | Caution |
|---|---|---|
| 1 tsp baking powder | ⅓ tsp baking soda + ½ tsp cream of tartar (or a tested substitute) | Do not swap baking soda and baking powder 1:1. |
| 1 cup buttermilk | 1 Tbsp lemon juice or vinegar plus milk to make 1 cup, let stand a few minutes | A cooking hack, not a cultured product. |
| 1 cup whole milk | ½ cup evaporated milk + ½ cup water, or the bag’s powdered-milk directions | |
| 1 Tbsp fresh herb | 1 tsp dried of the same herb (start there and taste) | Dried is more concentrated. |
| 1 clove garlic | ¼–½ tsp garlic powder (very approximate) | Powder is not the same flavor. |
| 1 cup butter, for baking | 1 cup margarine is a rough stand-in in some recipes; oil is not a 1:1 swap for solid fat in pastry | When the recipe is a bakery formula, follow it. |
| 1 oz unsweetened chocolate | 3 Tbsp cocoa + 1 Tbsp fat, in a pinch | Taste and texture will move. |
| 1 cup cake flour | 1 cup less 2 Tbsp all-purpose, plus 2 Tbsp cornstarch, sifted — a common kitchen swap | Not the same as real cake flour for a fine crumb. |
| 1 egg, for binding (not for a custard) | in some batters, 3 Tbsp of a beaten egg, or a tested “flax egg” (1 Tbsp ground flax + 3 Tbsp water) | Custards, mayonnaise, and meringues are not the place to invent this. |
| 1 cup sugar | do not casually swap an equal volume of honey or a non-sugar sweetener without a tested recipe | Honey is wetter and sweeter; reduce other liquid if you must experiment. |
| Active dry yeast vs instant | They are not always 1:1 in time or amount; follow the packet | Proof active dry in warm water if the packet says to. |
| High-altitude baking (Utah) | Water boils cooler; cakes and breads often want a little more liquid, a little less leavening, a slightly hotter oven, or a tested high-altitude recipe | USU Extension and USDA have altitude notes. Salt Lake (~4,200 ft) is already high enough to notice; the canyons more so. |
A pinch is under ⅛ tsp; a dash is a few drops or a shake. Oven temperatures: 250 °F = 120 °C, 300 = 150, 325 = 165, 350 = 175, 375 = 190, 400 = 200, 425 = 220, 450 = 230, 500 = 260, approximate and rounded to the numbers people actually set. Simmer is just below a boil; a rolling boil is obvious.
Food safety, not folklore: keep cold food cold and hot food hot. USDA’s usual home figures are refrigerate perishable food within 2 hours (1 hour if it is above 90 °F), cook poultry to 165 °F in the thickest part, ground meats to 160 °F, whole beef/pork steaks and roasts to at least 145 °F plus a rest, and leftovers to 165 °F — measured with a thermometer, not hope. Reheat canned leftovers in a pot, not in the can. See the pantry and USU materials for canning, which is a different problem.
Volume relations are U.S. customary kitchen measures (NIST-consistent). Substitutions are ordinary culinary practice, not a bakery specification. Internal temperatures: USDA FSIS public figures. High-altitude note: land-grant extension practice (USU).
Morse, signaling, and ground-to-air
Distress in almost any medium is a pattern of three: three whistle blasts, three gunshots, three fires, three flashes. SOS in Morse is ...---... as one prosign. A brightly colored panel, a mirror flash at an aircraft, and a fire that makes smoke against snow or a dark hill will be seen farther than a shout.
A signal mirror: sight the target through the hole or along your aimed reflection, and flash in deliberate bursts, not a continuous glitter that looks like water. At night, a light that is not a strobe should still be aimed, not waved at the clouds.
Ground-to-air (body and panel, survival-manual family)
The figures below follow the long-standing U.S. military survival-manual set (FM 21-76 and its successors, already in this archive). Make the marks large — on the order of several meters, high contrast, and in the open. Stay by them if you can. An aircraft may rock its wings for “message received,” or circle; do not walk in front of a landing helicopter.
| Symbol (made with cloth, rocks, or your body as the manual shows) | Usual meaning |
|---|---|
| V | Need help / require assistance |
| X | Need medical help |
| N | No, or negative |
| Y | Yes, or affirmative |
| ↑ (arrow) | Going this way |
| ▲ or a triangle | probably a safe place to land, in some lists — confirm in FM 21-76 before you stake a pilot’s life on a symbol you half-remember |
| a large, obvious SOS | universally understood; use rocks, trampling, or contrasting cloth |
Body signals in FM 21-76 include both arms up for “need help,” one arm up and one down for “need no help / all OK,” and pointing for direction. If you have the manual, use the pictures, not this sentence.
Radio distress: if you have a licensed amateur radio, a call on a local repeater, 146.52, or a known net (see radio/utah/nets.html) with your call sign, location, and the nature of the trouble is the adult way to do it. Marine and aviation distress frequencies are not toys and are not amateur allocations. 911, where it still works, still works.
SOS and the “rule of three” are customary distress signs. Ground-to-air panel meanings: U.S. Army FM 21-76 / later survival FMs, on this shelf in quickstart-72hr and survival/. Confirm a symbol in the manual before you rely on it.
Trig, roots, and inch decimals
Computed here from the usual formulae so the figures can be checked. Round-off is to four or five decimals, which is plenty for shop and field work.
Sine, cosine, and tangent — every 5°
| Degrees | sin | cos | tan |
|---|---|---|---|
| 0 | 0.0000 | 1.0000 | 0.0000 |
| 5 | 0.0872 | 0.9962 | 0.0875 |
| 10 | 0.1736 | 0.9848 | 0.1763 |
| 15 | 0.2588 | 0.9659 | 0.2679 |
| 20 | 0.3420 | 0.9397 | 0.3640 |
| 25 | 0.4226 | 0.9063 | 0.4663 |
| 30 | 0.5000 | 0.8660 | 0.5774 |
| 35 | 0.5736 | 0.8192 | 0.7002 |
| 40 | 0.6428 | 0.7660 | 0.8391 |
| 45 | 0.7071 | 0.7071 | 1.0000 |
| 50 | 0.7660 | 0.6428 | 1.1918 |
| 55 | 0.8192 | 0.5736 | 1.4281 |
| 60 | 0.8660 | 0.5000 | 1.7321 |
| 65 | 0.9063 | 0.4226 | 2.1445 |
| 70 | 0.9397 | 0.3420 | 2.7475 |
| 75 | 0.9659 | 0.2588 | 3.7321 |
| 80 | 0.9848 | 0.1736 | 5.6713 |
| 85 | 0.9962 | 0.0872 | 11.4301 |
| 90 | 1.0000 | 0.0000 | ∞ |
Radians = degrees × π/180. Law of sines: a/sin A = b/sin B = c/sin C. Law of cosines: c² = a² + b² − 2ab cos C. A right triangle with opposite / hypotenuse = sin; adjacent / hypotenuse = cos; opposite / adjacent = tan.
Square roots, cube roots, and squares
| n | √n | ∛n | n² |
|---|---|---|---|
| 1 | 1.00000 | 1.00000 | 1 |
| 2 | 1.41421 | 1.25992 | 4 |
| 3 | 1.73205 | 1.44225 | 9 |
| 4 | 2.00000 | 1.58740 | 16 |
| 5 | 2.23607 | 1.70998 | 25 |
| 6 | 2.44949 | 1.81712 | 36 |
| 7 | 2.64575 | 1.91293 | 49 |
| 8 | 2.82843 | 2.00000 | 64 |
| 9 | 3.00000 | 2.08008 | 81 |
| 10 | 3.16228 | 2.15443 | 100 |
| 11 | 3.31662 | 2.22398 | 121 |
| 12 | 3.46410 | 2.28943 | 144 |
| 13 | 3.60555 | 2.35133 | 169 |
| 14 | 3.74166 | 2.41014 | 196 |
| 15 | 3.87298 | 2.46621 | 225 |
| 16 | 4.00000 | 2.51984 | 256 |
| 17 | 4.12311 | 2.57128 | 289 |
| 18 | 4.24264 | 2.62074 | 324 |
| 19 | 4.35890 | 2.66840 | 361 |
| 20 | 4.47214 | 2.71442 | 400 |
| 24 | 4.89898 | 2.88450 | 576 |
| 25 | 5.00000 | 2.92402 | 625 |
| 30 | 5.47723 | 3.10723 | 900 |
| 32 | 5.65685 | 3.17480 | 1024 |
| 36 | 6.00000 | 3.30193 | 1296 |
| 40 | 6.32456 | 3.41995 | 1600 |
| 48 | 6.92820 | 3.63424 | 2304 |
| 49 | 7.00000 | 3.65931 | 2401 |
| 50 | 7.07107 | 3.68403 | 2500 |
| 60 | 7.74597 | 3.91487 | 3600 |
| 64 | 8.00000 | 4.00000 | 4096 |
| 72 | 8.48528 | 4.16017 | 5184 |
| 80 | 8.94427 | 4.30887 | 6400 |
| 81 | 9.00000 | 4.32675 | 6561 |
| 90 | 9.48683 | 4.48140 | 8100 |
| 100 | 10.00000 | 4.64159 | 10000 |
Inch fractions (32nds) to decimal inches and millimetres
| Fraction | Decimal inches | mm |
|---|---|---|
| 1/32" | 0.031250 | 0.794 |
| 1/16" | 0.062500 | 1.587 |
| 3/32" | 0.093750 | 2.381 |
| 1/8" | 0.125000 | 3.175 |
| 5/32" | 0.156250 | 3.969 |
| 3/16" | 0.187500 | 4.762 |
| 7/32" | 0.218750 | 5.556 |
| 1/4" | 0.250000 | 6.350 |
| 9/32" | 0.281250 | 7.144 |
| 5/16" | 0.312500 | 7.938 |
| 11/32" | 0.343750 | 8.731 |
| 3/8" | 0.375000 | 9.525 |
| 13/32" | 0.406250 | 10.319 |
| 7/16" | 0.437500 | 11.112 |
| 15/32" | 0.468750 | 11.906 |
| 1/2" | 0.500000 | 12.700 |
| 17/32" | 0.531250 | 13.494 |
| 9/16" | 0.562500 | 14.287 |
| 19/32" | 0.593750 | 15.081 |
| 5/8" | 0.625000 | 15.875 |
| 21/32" | 0.656250 | 16.669 |
| 11/16" | 0.687500 | 17.462 |
| 23/32" | 0.718750 | 18.256 |
| 3/4" | 0.750000 | 19.050 |
| 25/32" | 0.781250 | 19.844 |
| 13/16" | 0.812500 | 20.637 |
| 27/32" | 0.843750 | 21.431 |
| 7/8" | 0.875000 | 22.225 |
| 29/32" | 0.906250 | 23.019 |
| 15/16" | 0.937500 | 23.812 |
| 31/32" | 0.968750 | 24.606 |
| 1/1" | 1.000000 | 25.400 |
1 in = 25.4 mm exactly (SI / NIST). Trigonometric values computed from the standard library.
Sheet metal, screws, nails, and fence cloth
Manufacturer’s standard steel sheet (approximate)
These are conventional U.S. steel-sheet gauge thicknesses used in the shop, not an ASTM or federal numbered standard, and not galvanized or aluminum gauge (those differ). Measure when it matters.
| Gauge | inches (approx.) | mm (approx.) |
|---|---|---|
| 10 | 0.135 | 3.42 |
| 12 | 0.105 | 2.66 |
| 14 | 0.075 | 1.90 |
| 16 | 0.060 | 1.52 |
| 18 | 0.048 | 1.21 |
| 20 | 0.036 | 0.91 |
| 22 | 0.030 | 0.76 |
| 24 | 0.024 | 0.61 |
| 26 | 0.018 | 0.45 |
| 28 | 0.015 | 0.38 |
Wood-screw sizes (body and typical pilot)
| Number | Shank Ø in (approx.) | Pilot in softwood (about) | Pilot in hardwood (about) |
|---|---|---|---|
| #4 | 0.112 | 1/16 | 3/32 |
| #6 | 0.138 | 5/64 | 7/64 |
| #8 | 0.164 | 3/32 | 1/8 |
| #10 | 0.190 | 7/64 | 9/64 |
| #12 | 0.216 | 1/8 | 5/32 |
| #14 | 0.242 | 9/64 | 11/64 |
A pilot that is a little small and a shank clearance in the top piece will pull a joint tight. Soap or wax on the threads helps in hardwood. Do not use a wood screw as if it were a lag bolt in a structural joint.
Common nails — length and approximate count per pound
| Penny | Length (in) | Nails per lb (about) |
|---|---|---|
| 2d | 1 | about 850 |
| 4d | 1 1/2 | about 300 |
| 6d | 2 | about 180 |
| 8d | 2 1/2 | about 100 |
| 10d | 3 | about 65 |
| 16d | 3 1/2 | about 45 |
| 20d | 4 | about 30 |
| 60d | 6 | about 10 |
Penny-system lengths are the long-standing U.S. common-nail sizes (a 10d common is 3 in). Counts per pound are typical for common (not box or sinker) nails and vary by maker.
Wire cloth and poultry fence
| Mesh | Note |
|---|---|
| 1/4 in / 6 mm hardware cloth | Mice, small snakes; preferred over chicken wire for a coop floor or run skirt. |
| 1/2 in hardware cloth | Weasels still get through 1-inch holes; 1/2 in is a common run wall. |
| 1 in chicken wire (hex netting) | Keeps chickens in, not raccoons or dogs out. Use only as a visual/light fence, not as predator proofing. |
| 2 in × 4 in welded stock fence | Cattle/sheep panels; too open for poultry. |
| Buried apron, 12–18 in out, or 6–12 in down | Stops dogs, foxes, and raccoons from digging under a run. Utah coyotes and neighborhood dogs both dig. |
Voltage drop, 12-volt systems, and two-stroke mix
Approximate copper voltage drop (20 °C, DC or single-phase two-wire)
One-way length is the run to the load, not the round trip (the factor of 2 is already in the formula). VD = 2 × I × R × L ÷ 1000, with R in ohms per 1,000 ft and L in feet. The current columns are the current that produces about a 3% drop at the stated voltage and one-way length. This is arithmetic from the AWG resistance formula, not a reprint of the National Electrical Code and not an ampacity table. Heat, bundling, and insulation temperature are why a code table and this 3% chart are not the same thing.
| AWG | Ω / 1,000 ft (Cu, 20 °C) | 12 V, 10 ft, 3% | 12 V, 20 ft, 3% | 12 V, 50 ft, 3% | 120 V, 50 ft, 3% |
|---|---|---|---|---|---|
| 18 | 6.385 | 2.8 | 1.4 | 0.6 | 5.6 |
| 16 | 4.015 | 4.5 | 2.2 | 0.9 | 9.0 |
| 14 | 2.525 | 7.1 | 3.6 | 1.4 | 14.3 |
| 12 | 1.588 | 11.3 | 5.7 | 2.3 | 22.7 |
| 10 | 0.999 | 18.0 | 9.0 | 3.6 | 36.0 |
| 8 | 0.628 | 28.7 | 14.3 | 5.7 | 57.3 |
| 6 | 0.395 | 45.6 | 22.8 | 9.1 | 91.1 |
| 4 | 0.248 | 72.4 | 36.2 | 14.5 | 144.9 |
| 2 | 0.156 | 115.2 | 57.6 | 23.0 | 230.4 |
| 0 | 0.098 | 183.2 | 91.6 | 36.6 | 366.3 |
AWG diameters from the ASTM B258 / NBS formula used in the main electrical section; copper resistivity 10.371 Ω·cmil/ft at 20 °C.
12-volt practice
| Topic | Note |
|---|---|
| Typical passenger-car starting battery | 12 V nominal; about 200–800 CCA depending on size. Resting, full, is about 12.6–12.8 V; 12.0 V is roughly half; 11.9 V or less under no load is a sick battery. These are order-of-magnitude figures, not a load-test. |
| Series vs. parallel | Series adds voltage (two 12 V in series = 24 V, same amp-hours). Parallel adds amp-hours (two 12 V, 100 Ah in parallel = 12 V, 200 Ah) at the same voltage. Mix of ages or chemistries in parallel is a poor idea. |
| Starter cables / 12 V loads | A starter can draw hundreds of amps for a few seconds. Voltage drop in skinny leads is why jumper cables are fat. For lighting and radios, use the 3% table below. |
| Spark-plug gap (typical) | Many small engines sit around 0.025–0.030 in; many automotive plugs around 0.030–0.045 in. The number on the engine or plug chart wins when you have it. |
Two-stroke oil mix (U.S. gallon of gasoline)
| Ratio (gas:oil) | Oil to add | Note |
|---|---|---|
| 16:1 | 8 fl oz per U.S. gallon | Older two-strokes and some chainsaws; check the tool. |
| 32:1 | 4 fl oz per U.S. gallon | Common mid-century ratio. |
| 40:1 | 3.2 fl oz per U.S. gallon | Some later tools. |
| 50:1 | 2.6 fl oz per U.S. gallon | Very common on modern two-stroke outdoor tools. |
Board measure, stairs, roofs, tanks, insulation, and roof-water
Board feet and log rules
| Item | Figure |
|---|---|
| Board foot | 1 in × 12 in × 1 ft, or 144 cubic inches, of nominal lumber. BF = thickness (in) × width (in) × length (ft) ÷ 12, using nominal thickness and width for the usual U.S. tally. |
| Example | A 2×6×10 is 2×6×10÷12 = 10 board feet (nominal). |
| Doyle log rule (U.S. traditional, underestimates small logs) | BF ≈ (D − 4)² × L ÷ 16, D = small-end diameter in inches inside bark, L = length in feet. A scale, not a cubic-foot volume. |
| International ¼-inch rule | A later, usually fairer log scale; Forest Products Laboratory discusses all three common U.S. rules (Doyle, Scribner, International) in the Wood Handbook in construction/. |
U.S. board-foot definition and the Doyle form are long-standing lumber-trade arithmetic. Details and the other log rules are in the USDA Forest Products Laboratory Wood Handbook, already in construction/.
Stairs (carpenter’s rules of thumb)
| Topic | Note |
|---|---|
| Traditional carpenter’s rule | 2 × rise + run ≈ 24–25 in (some shops use 17–18 in for rise+run only). This is a comfort rule of thumb, not a building-code table. Current residential codes are copyrighted and are not copied here. |
| Comfortable range (field) | Rise about 7–7½ in, run (tread) about 10–11 in, all risers equal within a small fraction of an inch. |
| Number of risers | Floor-to-floor height in inches ÷ chosen rise, then adjust so every riser is the same. Treads = risers − 1 on a straight flight between floors. |
| Headroom and width | Watch headroom at the landing. A narrow, steep ship-ladder is a different animal from a house stair. |
Common roof pitches — rafter length per foot of run
| Pitch (rise/run) | Angle | Rafter inches per foot of run (√(12²+rise²)) |
|---|---|---|
| Pitch 3/12 | 14.0° | 12.37 |
| Pitch 4/12 | 18.4° | 12.65 |
| Pitch 5/12 | 22.6° | 13.00 |
| Pitch 6/12 | 26.6° | 13.42 |
| Pitch 8/12 | 33.7° | 14.42 |
| Pitch 12/12 | 45.0° | 16.97 |
A 6/12 roof rises 6 in per foot of run. Rafter length (without overhang or birdsmouth) ≈ run × (the last column ÷ 12). Add overhang, and check the ridge and birdsmouth before you cut a stack of them.
Tank and pipe volumes
| Shape | U.S. gallons |
|---|---|
| Rectangular tank, U.S. gallons | gallons ≈ length × width × depth (all in inches) ÷ 231, or feet × feet × feet × 7.48. |
| Cylinder, upright, U.S. gallons | gallons ≈ d² × h × 0.0034 if d and h are in inches; or d² × h × 5.88 if d and h are in feet. (π/4 × 7.48.) |
| Pipe volume, U.S. gallons | gallons ≈ d² × L × 0.0408, with inside diameter d in inches and length L in feet. |
| 55-gallon drum | About 22.5 in ID and 33 in inside height for a typical steel drum; do not treat “55” as a precise fill if you need one. |
| I-275 tote / IBC (typical) | Often about 275 U.S. gallons (1,040 L) to the rated fill; check the plate. |
R-values, order of magnitude (U.S. customary, per inch unless noted)
| Material | About |
|---|---|
| Still air film, inside (about) | R-0.7 |
| Wood, softwood, per inch (about) | R-1.0 to R-1.4 |
| Plywood, per inch (about) | R-1.0 |
| Dense mineral wool / fiberglass batt, per inch (about) | R-3 to R-4 |
| Expanded polystyrene (EPS), per inch (about) | R-3.6 to R-4 |
| Extruded polystyrene (XPS), per inch (about) | R-5 |
| Polyisocyanurate, per inch (about) | R-5.5 to R-6.5 (age and facers matter) |
| Softwood-chip loose fill, per inch (about) | R-2 to R-3 |
| Snow, loose, per inch (about) | R-1 (a variable insulator; wet snow is worse) |
| Single pane of glass (about) | R-1 |
| Insulating glass, two pane, air (about) | R-2 |
Order-of-magnitude figures in the range published by DOE / ENERGY STAR and FPL wood-handbook style tables. Manufacturer’s labeled R-value, if you have the package, wins. These are not a code assembly table.
Rainwater catchment
| Item | Note |
|---|---|
| Rule | U.S. gallons ≈ roof area (ft²) × rainfall (inches) × 0.623. That is 1 inch of rain on 1 square foot ≈ 0.623 gallons. |
| Example, 1,000 ft² roof, 0.5 in rain | about 312 gallons before losses. |
| Losses | First-flush, splash, overflow, and dirty roofs eat a lot. A first-flush diverter and a screened inlet are worth more than a bigger dirty tank. |
| Utah note | Wasatch Front precipitation is modest and seasonal; a roof still makes useful garden or livestock water if you have the cistern and treat or filter to the use. Household drinking water still needs a real treatment step — see the water section and the EPA leaflet. |
1 in of rain on 1 ft² is 1/12 ft³ ≈ 0.6233 U.S. gallons.
Altitude cooking, safe temperatures, cans, and water use
Approximate boiling point of water vs elevation
Utah’s Wasatch Front sits roughly 4,200 ft in the Salt Lake valley and higher in the benches and canyons. Water is cooler when it “boils,” food takes longer, and canning recipes have to be adjusted. Use the USDA altitude adjustments in the canning guides already in the pantry wing; do not guess at canning times from this table alone.
| Elevation (ft) | Boiling point °F (approx.) | °C (approx.) |
|---|---|---|
| 0 (sea level) | 212 | 100.0 |
| 1,000 | 210.2 | 99.0 |
| 2,000 | 208.4 | 98.0 |
| 3,000 | 206.6 | 97.0 |
| 4,000 | 204.9 | 95.9 |
| 4,200 (about Salt Lake City) | 204.5 | 95.8 |
| 5,000 | 203.1 | 95.1 |
| 6,000 | 201.3 | 94.1 |
| 7,000 | 199.5 | 93.1 |
| 8,000 | 197.8 | 92.1 |
| 9,000 | 196.0 | 91.1 |
| 10,000 | 194.2 | 90.1 |
Approximate standard-atmosphere boiling points (about 1.8 °F or 1 °C drop per 1,000 ft in this range). A barometer and a thermometer beat the table if both are on hand.
USDA / FSIS minimum safe internal temperatures
| Food | Minimum internal temperature |
|---|---|
| Poultry (whole, parts, ground, leftovers with poultry) | 165 °F (74 °C) |
| Ground meats (beef, pork, lamb, veal) | 160 °F (71 °C) |
| Beef, pork, lamb, veal steaks, chops, roasts | 145 °F (63 °C) and rest 3 minutes |
| Fish and shellfish | 145 °F (63 °C) |
| Egg dishes, leftovers, casseroles | 165 °F (74 °C) |
| Eggs, fried or boiled, if you are being careful | Cook until the yolk and white are firm; dishes to 160 °F |
| Reheat leftovers | 165 °F (74 °C) |
| Hold hot food | 140 °F (60 °C) or hotter |
| Refrigerator | 40 °F (4 °C) or colder |
| Freezer | 0 °F (−18 °C) or colder |
USDA Food Safety and Inspection Service safe-minimum-internal-temperature chart. A thermometer in the thickest part, not touching bone, is the test; color is not.
Common U.S. can sizes (approximate net)
| Can | About |
|---|---|
| #1 picnic / 10½ oz | about 1¼ cups |
| #300 | about 1¾ cups |
| #303 | about 2 cups |
| #2 | about 2½ cups |
| #2.5 | about 3½ cups |
| #3 cylinder | about 5¾ cups |
| #10 (institutional) | about 12–13 cups (about 96–108 fl oz) |
Can-size names are trade usage and have wandered over the years. Weigh or measure when a recipe is tight. A #10 can is the big institutional can, not “ten inches.”
Water-use planning figures
| Use | Order of magnitude |
|---|---|
| Drinking and cooking, short-term emergency planning | About 1 gallon per person per day is the usual Ready.gov / FEMA planning floor; more in heat or with nursing, illness, or dry food. |
| A flush toilet | Often 1.6–6 gallons a flush depending on the fixture. A 5-gallon bucket and a latrine plan matter more than a pretty bathroom when the water stops. |
| A short shower | Often 10–25 gallons. |
| Livestock (very rough) | A dairy cow can drink tens of gallons a day; a horse often 5–15; a few chickens drink a small pan. Plan measured, not guessed, once you have animals. |
FEMA / Ready.gov household water planning; fixture volumes are typical U.S. ranges, not a meter reading.
pH, dilutions, welding rod notes, and tire codes
pH, in the usual aqueous sense
| pH | Familiar examples |
|---|---|
| 0–1 | Concentrated strong acids (battery acid is around 0–1). Treat as a burn hazard. |
| 2–3 | Lemon juice, vinegar (around 2–3). |
| 4–6 | Acidic soils, many fruits, black coffee. |
| 7 | Neutral (pure water at 25 °C). |
| 8–9 | Baking soda solution, seawater (around 8), many soaps. |
| 10–11 | Ammonia household cleaners, some soaps. |
| 12–14 | Household bleach (around 12–13), lye / drain cleaner (14 is a concentrated strong base). Burn hazard. |
A short metal activity series
| Item | Note |
|---|---|
| More easily oxidized (generally more reactive as metals) | K, Na, Ca, Mg, Al, Zn, Fe, Ni, Sn, Pb, H, Cu, Ag, Au, Pt (gold and platinum at the noble end). |
| Why it matters | A more active metal can displace a less active one from solution (iron in copper sulfate plates copper and eats the iron). It is also a reminder about galvanic corrosion: do not leave a steel fitting hard-coupled to copper in a wet line and expect it to last. |
Dilutions
| Rule | Note |
|---|---|
| C₁V₁ = C₂V₂ | The dilution equation for the same solute. Concentrated volume needed = (final concentration × final volume) ÷ starting concentration. |
| Example | To make 1 L of 1% from a 5% stock: 1 × 1 L ÷ 5 = 0.2 L of stock, plus water to 1 L. |
| Percent, field language | 1% w/v is 1 g in 100 mL. 1 ppm is 1 mg in 1 L (water). These are the usual dilute-aqueous approximations, not a chemistry-lab precise-mass definition. |
| Bleach | See the EPA emergency-disinfection table in the water section. Do not mix bleach with ammonia or acids. |
SMAW (stick) electrodes — starting notes, not a procedure
| Electrode | Field notes |
|---|---|
| E6010 / E6011 | Fast-freeze, deep penetration, good on dirty or galvanized-in-the-field steel if you must; 6011 is the AC-friendly cousin of 6010. Typical 1/8 in starting current is often in the neighborhood of 80–130 A. These are starting points, not a WPS. |
| E6013 | Easy, shallow to moderate penetration, pretty bead for thin work and practice. Typical 1/8 in often around 80–120 A. |
| E7018 | Low-hydrogen, stronger weld metal (the 70 is 70 ksi tensile in the old AWS numbering). Keep the rod dry. Typical 1/8 in often around 90–140 A, usually DCEP. A wet 7018 is a hydrogen-crack problem, not just an ugly bead. |
| Polarity, very briefly | Many 6010/7018 setups run DCEP (reverse). 6013 is more forgiving. The rod and the machine manual win. |
| Oxy-fuel cutting (order of magnitude) | A cutting oxygen jet, not the preheat flame, does the cut. Keep cylinders chained, acetylene under 15 psi in the hose, and flashback arrestors in place. This is not a cutting-torch course. |
AWS classification numbers are the standard U.S. naming (E70xx = 70 ksi class, and so on). Currents are typical starting ranges used in shops and older public-domain / Army welding notes, not a reprint of a current AWS or manufacturer data sheet. Practice on scrap.
Tire sidewall codes
| Topic | Note |
|---|---|
| Reading a typical P-metric sidewall | P215/65R16 95H — 215 mm section width, 65% aspect ratio (sidewall height / width), R = radial, 16 in rim, 95 = load index, H = speed rating. “P” is passenger; “LT” is light truck and is not the same load table. |
| Load index and speed rating | The number and letter are indexes, not a license to ignore the vehicle placard. The placard on the door jamb (or the official load table) is the authority for that vehicle. |
| DOT date | The last four digits of the DOT code are week and year of manufacture (for example 2319 is the 23rd week of 2019). Old rubber fails even with tread left. |
| Pressure | Set from the vehicle placard, cold, not from the sidewall maximum. The sidewall maximum is a limit, not a recommendation. |
NHTSA / tire-industry standard P-metric reading. Vehicle placard and the tire maker’s load table win over a sidewall maximum or a memory of “32 pounds.”
Animal vitals, field sanitation, and pumping head
Typical resting vital-sign ranges
Teaching and extension ranges for calm adults, not a diagnosis and not a pediatric or breed-specific chart. Fright, heat, pregnancy, and tiny or giant breeds sit outside the middle of the range. See also the pet first-aid page in the Pets wing.
| Animal | Rectal (or oral, human) temperature | Pulse / min | Breaths / min |
|---|---|---|---|
| Dog (adult, resting) | 100.5–102.5 °F | 70–120 | 15–30 |
| Cat (adult, resting) | 100.5–102.5 °F | 140–220 | 20–30 |
| Chicken (adult, resting) | 105–107 °F | 250–300 | 12–36 |
| Horse (adult, resting) | 99–101 °F | 28–44 | 10–24 |
| Adult human (for comparison) | about 97–99 °F oral | 60–100 | 12–20 |
Latrine siting and camp hygiene
| Topic | Note |
|---|---|
| Siting, field rule from the Army hygiene family of manuals | Downhill from the water source and the kitchen, and well away from both. A common teaching figure is on the order of 100 yards (about 90 m) from water and from food preparation when the ground will allow it. Never in a drainage that feeds the creek you drink from. |
| Soil and groundwater | A pit latrine in a high water table or in fractured rock can contaminate the well you still need. If you cannot get depth without hitting water, do not dig that hole there. |
| Cover and flies | A tight box, a lid, and lime or dry soil over deposits cut flies and smell. Hands get washed. This is not optional just because you are tired. |
| Closing out | When the pit is used down to a couple of feet from the surface, fill, mound, and mark it so the next person does not dig it up. |
Army field-hygiene teaching (the FM 21-10 / TP 4-02 family and the water and sanitation notes already in this archive). Distances are planning figures; local soil and slope can force a longer walk, not a shorter one toward the creek.
Pumping and head
| Topic | Note |
|---|---|
| Water is heavy | A U.S. gallon weighs about 8.34 lb at ordinary temperatures. A 5-gallon bucket is about 42 lb plus the bucket. |
| Pressure and head | 1 psi ≈ 2.31 ft of water head; 1 ft of head ≈ 0.433 psi. A 23 ft lift is about 10 psi just to get it there, before friction. |
| Suction lift | A perfect pump at sea level cannot pull more than about 33 ft of water; real pumps often sulk above 15–20 ft of suction lift. Put the pump down by the water when you can. |
| Friction | Long skinny hose eats head quickly. A short fat hose beats a long garden hose for moving volume. |
Hydrostatic figures from the density of water and the usual foot-of-head / psi conversion (NIST-consistent). Suction-lift limits are physics plus ordinary pump reality, not a particular manufacturer’s curve.
64ths, survey measure, calories, heat index, knots, concrete, planting, and stars
Every 64th of an inch
| Fraction | Decimal inches | mm |
|---|---|---|
| 1/64" | 0.015625 | 0.397 |
| 1/32" | 0.031250 | 0.794 |
| 3/64" | 0.046875 | 1.191 |
| 1/16" | 0.062500 | 1.587 |
| 5/64" | 0.078125 | 1.984 |
| 3/32" | 0.093750 | 2.381 |
| 7/64" | 0.109375 | 2.778 |
| 1/8" | 0.125000 | 3.175 |
| 9/64" | 0.140625 | 3.572 |
| 5/32" | 0.156250 | 3.969 |
| 11/64" | 0.171875 | 4.366 |
| 3/16" | 0.187500 | 4.762 |
| 13/64" | 0.203125 | 5.159 |
| 7/32" | 0.218750 | 5.556 |
| 15/64" | 0.234375 | 5.953 |
| 1/4" | 0.250000 | 6.350 |
| 17/64" | 0.265625 | 6.747 |
| 9/32" | 0.281250 | 7.144 |
| 19/64" | 0.296875 | 7.541 |
| 5/16" | 0.312500 | 7.938 |
| 21/64" | 0.328125 | 8.334 |
| 11/32" | 0.343750 | 8.731 |
| 23/64" | 0.359375 | 9.128 |
| 3/8" | 0.375000 | 9.525 |
| 25/64" | 0.390625 | 9.922 |
| 13/32" | 0.406250 | 10.319 |
| 27/64" | 0.421875 | 10.716 |
| 7/16" | 0.437500 | 11.112 |
| 29/64" | 0.453125 | 11.509 |
| 15/32" | 0.468750 | 11.906 |
| 31/64" | 0.484375 | 12.303 |
| 1/2" | 0.500000 | 12.700 |
| 33/64" | 0.515625 | 13.097 |
| 17/32" | 0.531250 | 13.494 |
| 35/64" | 0.546875 | 13.891 |
| 9/16" | 0.562500 | 14.287 |
| 37/64" | 0.578125 | 14.684 |
| 19/32" | 0.593750 | 15.081 |
| 39/64" | 0.609375 | 15.478 |
| 5/8" | 0.625000 | 15.875 |
| 41/64" | 0.640625 | 16.272 |
| 21/32" | 0.656250 | 16.669 |
| 43/64" | 0.671875 | 17.066 |
| 11/16" | 0.687500 | 17.462 |
| 45/64" | 0.703125 | 17.859 |
| 23/32" | 0.718750 | 18.256 |
| 47/64" | 0.734375 | 18.653 |
| 3/4" | 0.750000 | 19.050 |
| 49/64" | 0.765625 | 19.447 |
| 25/32" | 0.781250 | 19.844 |
| 51/64" | 0.796875 | 20.241 |
| 13/16" | 0.812500 | 20.637 |
| 53/64" | 0.828125 | 21.034 |
| 27/32" | 0.843750 | 21.431 |
| 55/64" | 0.859375 | 21.828 |
| 7/8" | 0.875000 | 22.225 |
| 57/64" | 0.890625 | 22.622 |
| 29/32" | 0.906250 | 23.019 |
| 59/64" | 0.921875 | 23.416 |
| 15/16" | 0.937500 | 23.812 |
| 61/64" | 0.953125 | 24.209 |
| 31/32" | 0.968750 | 24.606 |
| 63/64" | 0.984375 | 25.003 |
1 in = 25.4 mm exactly.
Survey, sea, and specialty units
| Unit | U.S. / customary | Notes / SI |
|---|---|---|
| 1 link (Gunter's) | 7.92 in | 0.201 m |
| 1 rod / pole / perch | 16.5 ft (25 links) | 5.029 m |
| 1 chain (Gunter's) | 66 ft (100 links, 4 rods) | 20.117 m |
| 1 furlong | 660 ft (10 chains) | 201.17 m |
| 1 statute mile | 5,280 ft (80 chains) | 1,609.344 m exactly (US, 1959) |
| 1 acre | 43,560 ft² (10 square chains) | 4,046.86 m² |
| 1 section (U.S. Public Land Survey, nominal) | 1 mile², 640 acres | A real section can be short or long; read the plat. |
| 1 township (nominal) | 36 sections, 6 miles square | Same caution as sections. |
| 1 nautical mile (international) | 1,852 m exactly | about 6,076.12 ft |
| 1 fathom | 6 ft | 1.829 m |
| 1 cable (U.S. Navy traditional, about) | 120 fathoms / 720 ft | Varies by navy; do not survey with it. |
| Troy ounce | 480 grains, 31.1035 g | Precious metals. Not the 28.35 g avoirdupois ounce. |
| Avoirdupois ounce | 437.5 grains, 28.3495 g | Ordinary U.S. food and shop ounce. |
| 1 stone (UK) | 14 lb avoirdupois | 6.350 kg |
| 1 hundredweight, U.S. (short cwt) | 100 lb | 45.36 kg |
| 1 long (Imperial) hundredweight | 112 lb | 50.80 kg |
| Flow, useful identity | 1 cfs = 448.8 gpm (U.S.) | 1 U.S. gpm = 0.0631 L/s |
Gunter's chain and the U.S. Public Land Survey units are the reason rural property in Utah is still talked about in chains and acres. The international nautical mile is 1,852 m (SI brochure / IHO). The 1959 international yard and pound make the statute mile 1,609.344 m exactly.
More staple energy figures (approximate)
| Food | kcal (approximate) |
|---|---|
| Wheat, white flour, 100 g | about 364 |
| Wheat, whole-grain flour, 100 g | about 340 |
| Dry white rice, 100 g | about 365 |
| Dry brown rice, 100 g | about 370 |
| Dry rolled oats, 100 g | about 380 |
| Dry pinto beans, 100 g | about 347 |
| Dry lentils, 100 g | about 352 |
| Dry pasta, 100 g | about 370 |
| Potato, raw, 100 g | about 77 |
| White sugar, 100 g | about 387 |
| Honey, 100 g | about 304 |
| Butter, 100 g | about 717 |
| Vegetable oil, 100 g (about 7 Tbsp) | about 884 |
| Peanut butter, 100 g | about 588 |
| Whole milk, 100 g (about 3.4 fl oz) | about 61 |
| Cheddar, 100 g | about 400 |
| Eggs, whole, 100 g (about 2 large) | about 143 |
| Chicken, dark meat, roasted, 100 g | about 200 |
| Beef, ground, 80% lean, cooked, 100 g | about 270 |
| Salmon, cooked, 100 g | about 200 |
| Hard red wheat, dry berries, 1 lb | about 1,500–1,600 |
| U.S. gallon of whole milk | about 2,400 |
| U.S. gallon of vegetable oil | about 31,000 (do not drink a gallon of oil; this is energy density) |
| A very rough adult field ration target | 2,000–3,000 kcal/day depending on cold, work, size, and whether you are trying to maintain weight |
USDA FoodData Central typical values, rounded. Brands and moisture move the number. A food scale and the pantry guides beat a memorized calorie.
Heat index, shade (°F) — NWS-style chart
Air temperature in the first column, relative humidity across the top, apparent temperature in the cells. These are the usual National Weather Service shade, light-wind values. Full sun can feel substantially hotter. A dash means you are off the usual published chart — treat it as dangerous either way. Heat index is not a bare-thermometer reading and is not defined the same way as wet-bulb globe temperature.
| Temp °F \ RH | 40% | 50% | 60% | 70% | 80% | 90% |
|---|---|---|---|---|---|---|
| 80 | 80 | 81 | 82 | 83 | 84 | 86 |
| 84 | 85 | 86 | 88 | 90 | 93 | 96 |
| 88 | 91 | 93 | 96 | 100 | 104 | 109 |
| 92 | 98 | 102 | 108 | 114 | 121 | 128 |
| 96 | 107 | 113 | 121 | 130 | 137 | 143 |
| 100 | 118 | 127 | 137 | 148 | — | — |
| 104 | 131 | 142 | — | — | — | — |
National Weather Service heat-index chart (public NWS values, shade).
Knots and remaining strength (order of magnitude)
These efficiencies are order-of-magnitude field figures from rope-work teaching, not a manufacturer's test for your exact rope. A knot is the weak point. Never treat a working load as a breaking load (see the knots section earlier).
| Knot | Very rough remaining strength |
|---|---|
| Bowline | often around 70% of the rope's listed strength, well tied in a suitable rope |
| Figure-eight follow-through / knot | often around 75–80% |
| Square (reef) knot | often around 50% or worse, and it can capsize — a binding knot, not a life-support knot |
| Sheet bend | often around 50–65%; double it for slippery or unequal lines |
| Clove hitch | can slip when slack or yanked; back it up |
| Trucker's hitch | a purchase, not a pretty knot; expect mid-range efficiency and watch what you hitch to |
| Overhand / thumb knot in the bight as a stopper | bulky; weakens the rope at the knot |
Concrete bags, slabs, and block counts
| Topic | Figure |
|---|---|
| 80 lb bag of Portland cement | A common bag. A 94 lb bag is the old “1 cubic foot” sack still used in some mix math. |
| 60 or 80 lb bags of pre-mix concrete | An 80 lb bag of pre-mix often yields about 0.60 ft³; a 60 lb bag about 0.45 ft³. Read the bag. 27 ft³ = 1 yd³, so you need on the order of 45 of the 80 lb bags per cubic yard. |
| Coverage, 4 in slab | 1 yd³ covers 27 ft² at 12 in thick, so about 81 ft² at 4 in, before waste. Order extra. |
| Mortar, very rough | A typical 80 lb bag of mortar mix, plus sand if it is not pre-blended as a complete mix, is a small-job figure — read the bag for “number of brick or block.” A concrete masonry block 8×8×16 takes a lot more mortar than a face brick. |
| 8×8×16 block, wall area | Each block face is 8 in × 16 in = 0.89 ft², so about 113 block per 100 ft² of wall, plus corners and waste. That is a count, not a structural design. |
Soil temperatures and planting (field, not a Utah calendar)
| Crop group | Typical minimum soil temperature to plant |
|---|---|
| Peas, spinach, lettuce (cool) | often 35–45 °F and up |
| Beets, carrots, cabbage, onions | often 40–50 °F |
| Beans, sweet corn, cucumbers | often 60 °F and up; beans rot in cold wet ground |
| Tomatoes, peppers, squash, melon (warm) | often 65–70 °F and up; do not rush these in a Wasatch Front April |
| Potatoes | often 45–55 °F, after the worst of a hard freeze is past |
| A soil thermometer | Beats the calendar. Utah valley last-spring and first-fall frost dates move by town and bench; use NOAA / NCEI normals for your site rather than a single “Utah” date. |
Common land-grant / USDA garden teaching ranges. A soil thermometer and your local NOAA frost normals beat a copied calendar.
Drinking-water order of magnitude, people and animals
| Who | Very rough daily water |
|---|---|
| Adult human, planning floor | 1 gallon/day drinking and cooking, more in heat (Ready.gov). |
| Lactating woman, hard work, or heat | Often well above the 1-gallon floor. |
| Dog, typical pet | About ½–1+ oz per pound of body weight per day, more in heat or on dry food; a 50 lb dog often drinks on the order of a quart to a couple of quarts. |
| Cat | Less than a dog, but canned food vs dry changes it a lot. Always have water out. |
| Laying hen | On the order of 0.2–0.5 pint (about 0.1–0.25 L) a day, more in heat; a small flock's waterer goes faster than people expect. |
| Horse | Often 5–15 gallons/day, more in heat or on dry hay. |
| Cattle, cow-calf vs dairy | A dry cow may drink on the order of 10–20 gallons; a milking dairy cow can be much more (tens of gallons). Do not plan a dairy on a hose you have not measured. |
A few sky landmarks (Northern Hemisphere, mid-latitudes)
| Landmark | How you use it |
|---|---|
| Polaris (North Star) | End of the Little Dipper's handle; almost on the north celestial pole. Altitude ≈ your latitude. See the navigation section. |
| Big Dipper (Ursa Major) | The two pointer stars at the bowl's front point to Polaris, about five times the pointer-span onward. |
| Cassiopeia | The W, on the opposite side of Polaris from the Dipper; also points you to the pole when the Dipper is low. |
| Orion | Winter sky. The belt points to Sirius (southeast of the belt in the northern hemisphere evening) and, the other way, toward Aldebaran / Taurus. |
| Sirius | Brightest star in the night sky; follow Orion's belt. |
| Summer Triangle | Vega, Deneb, and Altair; a high, obvious summer/autumn landmark. |
| Scorpius / Antares | Low summer southern sky in Utah; reddish Antares in the scorpion's body. Watch that you do not confuse it with a planet. |
| Planets | Do not move with the star field over weeks; they wander. A planet can be brighter than most stars and will not twinkle as much. |
Planets and the Moon will sit among these and confuse a hasty look. The navigation section in the front of the book covers Polaris and declination in more detail.
Useful constants and source list
| Constant | Value | Note |
|---|---|---|
| Speed of light in vacuum c | 299,792,458 m/s exactly | SI 2019; the metre is defined from this |
| Standard gravity g | 9.80665 m/s² exactly | conventional standard; local g is a bit less in high Utah, a bit more at sea level in some places |
| Planck constant h | 6.62607015×10−34 J·s exactly | SI 2019 |
| Elementary charge e | 1.602176634×10−19 C exactly | SI 2019 |
| Avogadro constant NA | 6.02214076×1023 mol−1 exactly | SI 2019 |
| Boltzmann constant k | 1.380649×10−23 J/K exactly | SI 2019 |
| Molar gas constant R = NA k | 8.314462618 J/(mol·K) | derived, exact from the above |
| Standard atmosphere | 101,325 Pa | 14.69595 psi; 760 mmHg |
| Ice point (ITS convention) | 273.15 K = 0 °C | |
| Stefan–Boltzmann σ | 5.670374…×10−8 W/(m²·K⁴) | derived |
| Electron mass me | 9.1093837×10−31 kg | CODATA / NIST |
| Proton mass mp | 1.6726219×10−27 kg | CODATA / NIST |
| Atomic mass unit u | 1.660539×10−27 kg | 1/12 of a ¹²C atom |
| Faraday constant F | 96,485.33 C/mol | NA e |
| Speed of sound, dry air, 20 °C, 1 atm | about 343 m/s (1,125 ft/s) | increases with the square root of absolute temperature |
| Standard density of dry air, 15 °C, 1 atm | 1.225 kg/m³ | ICAO standard-atmosphere sea-level figure |
| Water density, 4 °C | 999.97 kg/m³ ≈ 1000 | 8.34 lb/U.S. gal at ~60 °F is the shop figure |
| Latent heat of fusion, water | about 334 kJ/kg (144 Btu/lb) | ice to water at 0 °C |
| Latent heat of vaporization, water, 100 °C | about 2256 kJ/kg (970 Btu/lb) | why a steam burn is so nasty |
| Specific heat of liquid water | about 4.18 kJ/(kg·K) or 1 Btu/(lb·°F) | the original calorie |
| π | 3.141592653589793 | |
| e | 2.718281828459045 | |
| Golden ratio φ | (1+√5)/2 ≈ 1.618034 | |
| ln 10 | 2.302585092994 | log10 x = ln x / ln 10 |
| 1 radian | 180/π ° ≈ 57.2957795° |
Where the figures came from
- NIST SP 811 (2008), Guide for the Use of the International System of Units, and NIST SP 330 (2019), The International System of Units — both in
reference/. SI 2019 exact constants (c, h, e, k, NA) are in SP 330. - EPA 816-F-15-003 (September 2017), emergency drinking-water disinfection — in
food-water/. The bleach table is copied from that leaflet. - USDA FoodData Central typical energy values, USDA FSIS cooking temperatures, and USDA / FoodSafety.gov style storage notes.
- NOAA / NWS public wind and hurricane scales; NWS lightning 30–30 guidance.
- 47 CFR Part 97, ITU Morse, ICAO phonetics, and FCC Part 97.
- FM 21-76 and FM 4-25.11, in the survival and 72-hour wings; Hesperian Where There Is No Doctor for medical pointers.
- AWG diameters from the ASTM B258 / NBS formula; copper resistance 10.371 Ω·cmil/ft at 20 °C; Unified and ISO tap-drill practice; IPS pipe bores; U.S. dressed-lumber sizes.
- Smithsonian Physical Tables, 7th ed. (1921), Machinery’s Handbook 6th ed. (1924), Kent (1916), and Trautwine — public-domain handbooks in
reference/— for older density and shop context. Modern Grade 5/8 torque and AWS electrode notes are typical shop figures, not a reprint of a current copyrighted handbook.
This book is a compilation of publicly citable facts for offline personal use at Installation 343. It is not Glover’s Pocket Ref, not a current Machinery’s Handbook, and not a substitute for the manuals it points to. If a figure here and a cited official source disagree, the official source wins.
Compiled 15 November 2026, America/Denver.