Installation 343 · offline · 15 November 2026, America/Denver

Archive Pocket Reference

A printable handbook of conversions, shop charts, water and food figures, first-aid reminders, radio, and navigation, compiled from public-domain and U.S. government sources already on this shelf.

About this Pocket Reference

A compact, printable handbook for Installation 343. It lives at the front of the First 72 Hours wing and again in the Reference wing. Use the search box on a phone, or print the bundled PDF and keep a paper copy with the 72-hour pamphlet.

This is not a license, a diagnosis, or a building code. Figures are compiled from U.S. government and public-domain sources cited under each section. For medicine, water treatment, structural work, and electrical premises wiring, verify the number in the cited manual before you bet a life or a building on it. Do not use this book as a substitute for a physician, pharmacist, licensed electrician, or engineer.

What this is not. It is not a copy of Glover’s Pocket Ref, the current Machinery’s Handbook, the National Electrical Code, or any other copyrighted handbook. Where a modern code is the controlling document (NEC ampacity, IRC span tables, vehicle torque), this book says so and stops.

Utah note. Many settled parts of the Wasatch Front sit near or above 4,000–5,000 feet. EPA boil-water times change at 5,000 feet. UTM is almost entirely zone 12N. Magnetic declination changes from year to year — use the rose on your map, not a memorized number.

Compiled 15 November 2026, America/Denver, for personal offline use. Primary sources: NIST SP 811 (2008) and SP 330 (2019) in reference/; EPA 816-F-15-003 (Sept 2017) in food-water/; NOAA/NWS public scales; USDA FoodData Central typical values; FM 21-76 and FM 4-25.11 in this archive; standard SI and AWG formulae (ASTM B258 / NBS).

Unit conversions

SI is the system this archive prefers for calculation. U.S. customary units are given because most of the hardware on this shelf is inch-based. Exact definitions below are from NIST SP 811 and SP 330 (2019 SI brochure), both in reference/.

Temperature

°F to °C: C = (F − 32) × 5/9. °C to °F: F = C × 9/5 + 32. Kelvin: K = C + 273.15. Absolute zero is 0 K = −273.15 °C = −459.67 °F. Ice point 0 °C; standard steam point 100 °C at 101325 Pa.

SI prefixes

PrefixSymbolFactor
yottaY1024
zettaZ1021
exaE1018
petaP1015
teraT1012
gigaG109
megaM106
kilok103
hectoh102
dekada101
decid10−1
centic10−2
millim10−3
microμ10−6
nanon10−9
picop10−12
femtof10−15
attoa10−18
zeptoz10−21
yoctoy10−24

Exact and conventional definitions

QuantityValueNote
inch (international)25.4 mm exactlysince 1 July 1959
avoirdupois pound0.45359237 kg exactlyNIST
U.S. liquid gallon (231 in3)3.785411784 L exactlyderived from the inch
U.S. liquid quart0.946352946 L¼ gallon
U.S. legal (survey) foot, pre-20231200/3937 m ≈ 0.3048006096 msee NIST; do not mix with the international foot on old plats
international foot0.3048 m exactly0.3048 m
yard0.9144 m exactly3 international feet
avoirdupois ounce28.349523125 g1/16 lb
avoirdupois (short) ton2000 lb = 907.18474 kg
long ton (UK)2240 lb ≈ 1016.0469 kg
metric ton (tonne)1000 kg
grain64.79891 mg exactly1/7000 lb
troy ounce (precious metals)31.1034768 g480 grains
atmosphere (standard)101325 Pa exactly14.69595 psi
bar100000 Pa exactly
mmHg (conventional torr ≈)133.322 Pa1 atm = 760 mmHg
calorie (IT)4.1868 Jnutrition “Calorie” = 1 kcal = 1000 cal
British thermal unit (IT)1055.05585 J≈ 0.293071 W·h
horsepower (mechanical)745.6999 W550 ft·lbf/s
electronvolt1.602176634×10−19 J exactlySI 2019

Length and area

FromToMultiply byNote
inmm25.4mm → in: ÷ 25.4
ftm0.3048m → ft: × 3.28084
ydm0.9144m → yd: × 1.09361
mile (statute)km1.609344km → mi: × 0.621371
nautical milem1852 exactly1 kt = 1 nmi/h
mil (0.001 in)μm25.4wire and sheet
fathomft61.8288 m
rod / poleft16.55.0292 m
chain (Gunter)ft66100 links; 80 ch = 1 mile
acreft2435604046.856 m2; 640 acres = 1 section
hectarem2100002.47105 acres

Volume

FromToMultiply byNote
fl oz (U.S. liq)mL29.5735320 fl oz UK pint is not a U.S. pint
cup (U.S. legal)mL240U.S. customary cup 236.588 mL; nutrition labels use 240
pint (U.S. liq)mL473.17616 fl oz
quart (U.S. liq)L0.94635332 fl oz
gallon (U.S. liq)L3.785412231 in3
gallon (U.S. liq)in3231 exactly
ft3L28.316857.48052 U.S. gal
tablespoonmL14.78683 tsp; ½ fl oz
teaspoonmL4.92892often taken as 5 mL in medicine cups — read the cup
barrel (oil, 42 gal)L158.987not a U.S. beer barrel (31 gal)
acre-footm31233.48325,851 U.S. gal

Mass

FromToMultiply byNote
ozg28.3495avoirdupois
lbkg0.45359237lb → kg exact
stonelb146.35029 kg
cwt (short, U.S.)lb10045.3592 kg
slugkg14.59390mass that 1 lbf accelerates at 1 ft/s2

Pressure

FromToMultiply byNote
psikPa6.894757kPa → psi: × 0.145038
psfPa47.88026
atmpsi14.69595101.325 kPa
barpsi14.50377100 kPa
inHg (0 °C conv.)kPa3.38639barometer
inH2O (60 °F)Pa248.84duct and gas draft
mmHg / torrPa133.322
kgf/cm2kPa98.0665≈ 14.223 psi

Energy and power

FromToMultiply byNote
ft·lbfJ1.355818
kcal (IT)kJ4.1868food Calorie = 1 kcal
Btu (IT)kJ1.0550563412 Btu ≈ 1 kWh
kWhMJ3.6 exactly3,600,000 J
hp·hMJ2.68452mechanical hp
therm (U.S.)MJ105.5≈ 100,000 Btu

Force: 1 lbf = 4.448222 N. 1 kgf = 9.80665 N. 1 kip = 1000 lbf.

Speed: 1 mph = 1.609344 km/h = 0.44704 m/s. 1 knot = 1.852 km/h exactly = 1.15078 mph.

Water at ~4 °C: density ≈ 1000 kg/m3 = 1.940 slug/ft3. 1 U.S. gal weighs about 8.34 lb at 60 °F. 1 ft3 of water weighs about 62.4 lb.

Inch fractions to decimal inches and millimetres

Every 64th of an inch. 1 in = 25.4 mm exactly.
n/64Reducedinchesmm
1/64—0.0156250.397
2/641/320.031250.794
3/64—0.0468751.191
4/641/160.06251.587
5/64—0.0781251.984
6/643/320.093752.381
7/64—0.1093752.778
8/641/80.1253.175
9/64—0.1406253.572
10/645/320.156253.969
11/64—0.1718754.366
12/643/160.18754.762
13/64—0.2031255.159
14/647/320.218755.556
15/64—0.2343755.953
16/641/40.256.350
17/64—0.2656256.747
18/649/320.281257.144
19/64—0.2968757.541
20/645/160.31257.938
21/64—0.3281258.334
22/6411/320.343758.731
23/64—0.3593759.128
24/643/80.3759.525
25/64—0.3906259.922
26/6413/320.4062510.319
27/64—0.42187510.716
28/647/160.437511.112
29/64—0.45312511.509
30/6415/320.4687511.906
31/64—0.48437512.303
32/641/20.512.700
33/64—0.51562513.097
34/6417/320.5312513.494
35/64—0.54687513.891
36/649/160.562514.287
37/64—0.57812514.684
38/6419/320.5937515.081
39/64—0.60937515.478
40/645/80.62515.875
41/64—0.64062516.272
42/6421/320.6562516.669
43/64—0.67187517.066
44/6411/160.687517.462
45/64—0.70312517.859
46/6423/320.7187518.256
47/64—0.73437518.653
48/643/40.7519.050
49/64—0.76562519.447
50/6425/320.7812519.844
51/64—0.79687520.241
52/6413/160.812520.637
53/64—0.82812521.034
54/6427/320.8437521.431
55/64—0.85937521.828
56/647/80.87522.225
57/64—0.89062522.622
58/6429/320.9062523.019
59/64—0.92187523.416
60/6415/160.937523.812
61/64—0.95312524.209
62/6431/320.9687524.606
63/64—0.98437525.003

NIST Special Publication 811, Guide for the Use of the International System of Units (2008); NIST SP 330, The International System of Units (2019). Survey-foot caution: U.S. survey foot was deprecated; use the international foot (0.3048 m) unless an older plat explicitly uses the survey foot.

Math, geometry, and trigonometry

Algebra

π ≈ 3.141592653589793. e ≈ 2.718281828459045. √2 ≈ 1.41421356. √3 ≈ 1.73205081. √5 ≈ 2.23606798. 1 radian = 180/π ≈ 57.2957795°. 1° = π/180 ≈ 0.01745329 rad.

Areas

ShapeAreaNotes
Square, side aA = a2P = 4a
Rectangle, sides a, bA = a bP = 2(a+b)
Triangle, base b, height hA = b h / 2also √[s(s−a)(s−b)(s−c)], s = (a+b+c)/2
Equilateral triangle, side aA = (√3 / 4) a2height = (√3 / 2) a
Circle, radius rA = π r2C = 2 π r; d = 2r
Annulus (ring), R, rA = π (R2 − r2)
Ellipse, semi-axes a, bA = π a bperimeter ≈ π [3(a+b) − √((3a+b)(a+3b))] (Ramanujan)
Trapezoid, bases a, b, height hA = (a+b) h / 2
Regular hexagon, side aA = (3√3 / 2) a2width flat-to-flat = √3 a
Sphere, radius r (surface)A = 4 π r2volume below
Cylinder (lateral), r, hA = 2 π r htotal + 2 π r2
Cone (lateral), r, slant LA = π r LL = √(r2+h2)

Volumes

ShapeVolume
Cube, side aV = a3
Rectangular boxV = a b c
CylinderV = π r2 h
SphereV = (4/3) π r3
Cone or pyramidV = (1/3) × base area × height
Frustum of a cone (r, R, h)V = (π h / 3) (R2 + R r + r2)
Torus, tube r, centerline RV = 2 π2 R r2
Barrel / tank approx.prefer the manufacturer or a dip chart; do not guess fuel volume from a rust line

Right triangles and trig

Pythagoras: c2 = a2 + b2 for the hypotenuse c. sin θ = opposite/hypotenuse, cos θ = adjacent/hypotenuse, tan θ = opposite/adjacent = sin/cos. Reciprocals: csc = 1/sin, sec = 1/cos, cot = 1/tan.

sin2θ + cos2θ = 1. Law of sines: a/sin A = b/sin B = c/sin C = 2R. Law of cosines: c2 = a2 + b2 − 2ab cos C.

Slope (grade) = rise/run. Percent grade = 100 × rise/run. A 100% grade is 45°. Roof pitch of 6/12 is a 6-inch rise in 12 inches of run (26.57°).

Exact or familiar values.
θ (°)sincostan
0010.0000
150.25880.96590.2679
300.5√3/2 ≈ 0.86601/√3 ≈ 0.5774
45√2/2 ≈ 0.7071√2/2 ≈ 0.70711
60√3/2 ≈ 0.86600.5√3 ≈ 1.7321
750.96590.25883.7321
9010—
Every 5 degrees, 0–90. For 95–180°: sin(180−θ)=sin θ, cos(180−θ)=−cos θ, tan is negative in quadrant II.
θ (°)sincostanrad
00.00001.00000.00000.0000
50.08720.99620.08750.0873
100.17360.98480.17630.1745
150.25880.96590.26790.2618
200.34200.93970.36400.3491
250.42260.90630.46630.4363
300.50000.86600.57740.5236
350.57360.81920.70020.6109
400.64280.76600.83910.6981
450.70710.70711.00000.7854
500.76600.64281.19180.8727
550.81920.57361.42810.9599
600.86600.50001.73211.0472
650.90630.42262.14451.1345
700.93970.34202.74751.2217
750.96590.25883.73211.3090
800.98480.17365.67131.3963
850.99620.087211.43011.4835
901.00000.0000∞1.5708

Small-shop arithmetic

Standard Euclidean geometry and trigonometry; radian definition from NIST SI (the radian is a coherent SI unit).

Fasteners, threads, drill and tap

Unified threads (UNC coarse, UNF fine) and ISO metric coarse are the ones you will actually meet in a U.S. shop and on imported hardware. Pitch diameter and class-of-fit (1A/2A/3A) live in the public-domain Machinery’s Handbook 6th (1924) and in later standards; the table below is the everyday tap-drill chart for about 75% thread, which is what most jobbers cut in unhardened steel.

A 75% tap drill is a starting point, not a law. In hard steel or a deep hole, go slightly larger (shallower thread) so the tap survives. In soft or thin material you may want more thread engagement. Broken taps are worse than a slightly loose thread.

Unified National Coarse (UNC) — 75% tap drill

ThreadMajor Ø (in)TPITap drillNote
#0-80*0.060080#56 (0.0465)UNF actually; listed because #0 has no UNC
#1-640.073064#53 (0.0595)
#2-560.086056#50 (0.0700)
#3-480.099048#47 (0.0785)
#4-400.112040#43 (0.0890)
#5-400.125040#38 (0.1015)
#6-320.138032#35 (0.1100)
#8-320.164032#29 (0.1360)
#10-240.190024#25 (0.1495)
#12-240.216024#16 (0.1770)
1/4-200.250020#7 (0.2010)very common
5/16-180.312518F (0.2570)
3/8-160.3750165/16 (0.3125)
7/16-140.437514U (0.3680)
1/2-130.50001327/64 (0.4219)
9/16-120.56251231/64 (0.4844)
5/8-110.62501117/32 (0.5312)
3/4-100.75001021/32 (0.6562)
7/8-90.8750949/64 (0.7656)
1-81.000087/8 (0.8750)
1⅛-71.1250763/64 (0.9844)
1¼-71.250071-7/64 (1.1094)
1½-61.500061-11/32 (1.3438)

Unified National Fine (UNF) — 75% tap drill

ThreadMajor Ø (in)TPITap drillNote
#1-720.073072#53 (0.0595)
#2-640.086064#50 (0.0700)
#3-560.099056#45 (0.0820)
#4-480.112048#42 (0.0935)
#5-440.125044#37 (0.1040)
#6-400.138040#33 (0.1130)
#8-360.164036#29 (0.1360)
#10-320.190032#21 (0.1590)
#12-280.216028#14 (0.1820)
1/4-280.250028#3 (0.2130)
5/16-240.312524I (0.2720)
3/8-240.375024Q (0.3320)
7/16-200.43752025/64 (0.3906)
1/2-200.50002029/64 (0.4531)
9/16-180.56251833/64 (0.5156)
5/8-180.62501837/64 (0.5781)
3/4-160.75001611/16 (0.6875)
7/8-140.87501413/16 (0.8125)
1-121.00001259/64 (0.9219)1-14 is UNEF
1-14 UNEF1.00001415/16 (0.9375)

Approximate 75% inch-series formula: tap-drill diameter ≈ major diameter − (1 / TPI). Then pick the nearest number, letter, or fractional drill.

ISO metric coarse — 75% tap drill

Approximate 75% thread. Formula: tap drill (mm) ≈ major Ø − pitch.
ThreadTap drillThreadTap drill
M2 × 0.41.6 mmM2.5 × 0.452.05 mm
M3 × 0.52.5 mmM3.5 × 0.62.9 mm
M4 × 0.73.3 mmM5 × 0.84.2 mm
M6 × 1.05.0 mmM8 × 1.256.8 mm
M10 × 1.58.5 mmM12 × 1.7510.2 mm
M14 × 2.012.0 mmM16 × 2.014.0 mm
M18 × 2.515.5 mmM20 × 2.517.5 mm
M22 × 2.519.5 mmM24 × 3.021.0 mm
M27 × 3.024.0 mmM30 × 3.526.5 mm

NPT pipe threads (nominal)

NPT is tapered (¾ in per foot). Dope or PTFE tape on the male threads; do not put tape over the first two threads if you need a clean start. These drills are shop-common starting points — a pipe tap wants a reamer or a specified drill, and a leak is how you find out you were short.
NominalTPIOD (in) approx.Tap / int. drill often usedClose alternative
1/8270.405R (0.339)5/16
1/4180.5407/167/16
3/8180.67537/649/16
1/2140.84023/3245/64
3/4141.05059/6429/32
111½1.3151-5/321-9/64
1¼11½1.6601-1/21-31/64
1½11½1.9001-47/641-23/32
211½2.3752-7/322-3/16

Head markings (as found on the bolt, not on the box)

Typical dry tightening torque (non-critical)

Do not use this table for cylinder heads, wheels, suspension, rod bolts, pressure vessels, or any fastener the manufacturer gives a number for. Lubricated threads can take a much lower torque to reach the same tension (often 25–40% less). Rust, plating, and threadlocker all change the number. When the book that came with the machine specifies a torque, that book wins.

Shop-typical starting values, inch-pound fasteners, unlubricated. Shown in ft·lbf except #10 (in·lbf).
SizeSAE Grade 5 (typical dry)SAE Grade 8 (typical dry)Note
#10-2420–25 in·lbf28–32 in·lbfuse in·lbf, not ft·lbf
#10-3222–28 in·lbf30–35 in·lbf
1/4-208 ft·lbf12 ft·lbf
1/4-281014
5/16-181725
5/16-241927
3/8-163045
3/8-243550
7/16-145070
7/16-205580
1/2-1375110
1/2-2085120
9/16-12110150
5/8-11150210
3/4-10270380
7/8-9430600
1-8645905

Clearance holes (close / free, approximate)

For a close-fit clearance, drill about 1/64 in over nominal on small bolts (¼ and 5/16) and 1/32 in over on ⅜–½. For a free fit (the hole is supposed to find the bolt), go another 1/32 in or so. A ¼-20 close clearance is often #7’s neighbor — letter C or 17/64; a free fit is often 9/32.

Number drill chart

Drillinmm
#10.22805.79
#20.22105.61
#30.21305.41
#40.20905.31
#50.20555.22
#60.20405.18
#70.20105.11
#80.19905.05
#90.19604.98
#100.19354.91
#110.19104.85
#120.18904.80
#130.18504.70
#140.18204.62
#150.18004.57
#160.17704.50
#170.17304.39
#180.16954.31
#190.16604.22
#200.16104.09
#210.15904.04
#220.15703.99
#230.15403.91
#240.15203.86
#250.14953.80
#260.14703.73
#270.14403.66
#280.14053.57
#290.13603.45
#300.12853.26
#310.12003.05
#320.11602.95
#330.11302.87
#340.11102.82
#350.11002.79
#360.10652.71
#370.10402.64
#380.10152.58
#390.09952.53
#400.09802.49
#410.09602.44
#420.09352.37
#430.08902.26
#440.08602.18
#450.08202.08
#460.08102.06
#470.07851.99
#480.07601.93
#490.07301.85
#500.07001.78
#510.06701.70
#520.06351.61
#530.05951.51
#540.05501.40
#550.05201.32
#560.04651.18
#570.04301.09
#580.04201.07
#590.04101.04
#600.04001.02
#610.03900.99
#620.03800.97
#630.03700.94
#640.03600.91
#650.03500.89
#660.03300.84
#670.03200.81
#680.03100.79
#690.02920.74
#700.02800.71
#710.02600.66
#720.02500.64
#730.02400.61
#740.02250.57
#750.02100.53
#760.02000.51
#770.01800.46
#780.01600.41
#790.01450.37
#800.01350.34

Letter drill chart

Drillinmm
A0.23405.94
B0.23806.05
C0.24206.15
D0.24606.25
E0.25006.35
F0.25706.53
G0.26106.63
H0.26606.76
I0.27206.91
J0.27707.04
K0.28107.14
L0.29007.37
M0.29507.49
N0.30207.67
O0.31608.03
P0.32308.20
Q0.33208.43
R0.33908.61
S0.34808.84
T0.35809.09
U0.36809.35
V0.37709.58
W0.38609.80
X0.397010.08
Y0.404010.26
Z0.413010.49

Fractional drills follow the usual 1/64-inch steps; see the inch-fraction table in Unit conversions. A well-stocked jobber set is 1/16 through ½ by 64ths, plus the number and letter drills you actually use for taps.

Thread forms: Unified inch (ASME B1.1 family) and ISO metric. Tap-drill sizes are the long-standing 75% shop set. Drill diameters are the standard number and letter sizes used in U.S. practice. Torque figures are typical unlubricated starting values, not a substitute for a manufacturer’s specification or a current engineering handbook.

Electrical, wire, Ohm’s law, batteries and solar

Ohm’s law and the AWG geometry are physics. Building-wire ampacity (how many amperes you may legally put on a premises circuit) is in the National Electrical Code, which is copyrighted and is not reproduced here. Use the NEC, the listing on the breaker and the cable, and a licensed electrician for house wiring. The copper table below is diameter, area, and DC resistance, which you may use for chassis wiring, radio lead-ins, and rough voltage-drop estimates.

Ohm’s law and power

V = I R. I = V / R. R = V / I. Power: P = V I = I2 R = V2 / R. Energy in watt-hours: E = P t (hours). Series resistances add. Parallel: 1/R = 1/R1 + 1/R2 + …; two equal resistors in parallel have half the resistance. Series voltage sources add (watch polarity). Kirchhoff: the currents into a node sum to zero; the voltages around a loop sum to zero.

AC (sine, RMS): a 120 V RMS household circuit has a peak of 120 √2 ≈ 170 V. Average power into a resistive load is VRMS IRMS. Power factor and motors are a longer story — see the repair and power wings.

Resistor color code

Four-band: digit, digit, multiplier, tolerance. Five-band: digit, digit, digit, multiplier, tolerance. Example: red-violet-yellow-gold = 27 × 104 = 270 kΩ, ±5%.

DigitColorTolerance (if used as band 4/5)Multiplier
0Black—×1
1Brown±1%×10
2Red±2%×100
3Orange—×1 k
4Yellow—×10 k
5Green±0.5%×100 k
6Blue±0.25%×1 M
7Violet±0.1%×10 M
8Gray±0.05%×100 M
9White—×1 G
—Gold±5%×0.1
—Silver±10%×0.01
—None (4-band)±20%—

AWG, copper, 20 °C DC resistance

Diameter formula (ASTM B258): d(inch) = 0.005 × 92(36−n)/39 for gauge n, with 1/0, 2/0, 3/0, 4/0 as n = 0, −1, −2, −3. Resistance uses 10.371 Ω·cmil/ft for annealed copper at 20 °C. Resistance rises with temperature (about 0.4% per °C for copper).

AWGØ inØ mmmm2cmilΩ / 1,000 ft (Cu, 20 °C)
4/00.460011.684107.219211600.00.0490
3/00.409610.40585.029167806.40.0618
2/00.36489.26667.431133076.50.0779
1/00.32498.25153.475105534.50.0983
10.28937.34842.40883692.70.1239
20.25766.54433.63166371.30.1563
30.22945.82726.67052634.80.1970
40.20435.18921.15141741.30.2485
50.18194.62116.77333102.40.3133
60.16204.11513.30226251.40.3951
70.14433.66510.54920818.30.4982
80.12853.2648.36616509.70.6282
90.11442.9066.63413092.70.7921
100.10192.5885.26110383.00.9988
110.09072.3054.1728234.11.2595
120.08082.0533.3096529.91.5882
130.07201.8282.6245178.52.0027
140.06411.6282.0814106.72.5254
150.05711.4501.6503256.83.1844
160.05081.2911.3092582.74.0155
170.04531.1501.0382048.25.0634
180.04031.0240.8231624.36.3849
190.03590.9120.6531288.18.0512
200.03200.8120.5181021.510.1524
210.02850.7230.410810.112.8019
220.02530.6440.326642.416.1429
230.02260.5730.258509.520.3558
240.02010.5110.205404.025.6682
250.01790.4550.162320.432.3670
260.01590.4050.129254.140.8141
270.01420.3610.102201.551.4656
280.01260.3210.081159.864.8969
290.01130.2860.064126.781.8335
300.01000.2550.051100.5103.1901
310.00890.2270.04079.7130.1204
320.00800.2020.03263.2164.0788
330.00710.1800.02550.1206.8995
340.00630.1600.02039.8260.8954
350.00560.1430.01631.5328.9831
360.00500.1270.01325.0414.8400
370.00450.1130.01019.8523.1036
380.00400.1010.00815.7659.6214
390.00350.0900.00612.5831.7673
400.00310.0800.0059.91048.8392

Voltage drop (DC, one-way then ×2 for the loop): V_drop = I × R, with R from the table × (feet/1000) × 2 for a go-and-return pair. A 12 V radio that draws 13 A on 20 ft of AWG 12 (round trip 40 ft) sees about 13 × (1.59 Ω/kft) × 0.040 ≈ 0.8 V drop, which is already noticeable.

Chassis-wiring current (rule of thumb, not NEC): many radio and automotive practice charts allow very roughly 10 A on AWG 18, 15–20 A on AWG 16, 20–25 A on AWG 14, 30–40 A on AWG 12, and 40–55 A on AWG 10 for short, well-cooled, chassis or vehicle runs with a fuse. These are not house-wiring numbers. Fuse for the wire, not for the load’s wishful thinking. Bundled, in-conduit, or high-ambient runs must be derated.

U.S. premises-wiring colors (informational)

Typical 120/240 V AC: black (and red, blue) are ungrounded “hot”; white or gray is grounded neutral; bare, green, or green/yellow is equipment grounding conductor. A white with colored tape in a switch loop may be hot — test, do not assume. This is a reminder of common practice, not permission to wire a house from a pocket book. The NEC is the code.

Batteries

Solar sizing (order of magnitude)

Energy in = energy out, after losses. A starting model:

panel watts × peak sun hours × 0.7 ≈ watt-hours into the battery per day

The 0.7 is a blunt derate for heat, dirt, angle, charge-controller and wiring losses — a well-aimed, clean winter array in a valley may do worse; a cold, clean, well-aimed array may do better. Utah winter sun hours are much shorter than July. Then:

battery usable Wh ≈ battery Ah × system volts × depth-of-discharge fraction

A 12 V, 100 Ah lead-acid that you will only take to 50% gives about 600 Wh usable. A 200 W panel in 5 equivalent sun hours with a 0.7 derate gives about 700 Wh/day — enough to float that battery if the loads actually are that small. Charge-controller current ≈ panel watts / battery volts, plus margin. Use a controller sized and typed (PWM vs MPPT) for the panel’s voltage.

The IC-2730A as a worked example

The Icom IC-2730A wants a 13.8 V supply and on the order of 13 A at full 50 W transmit (see the radio’s own manual in radio/icom-ic2730a/). A fused run of short, heavy cable (AWG 10 or 8, as the manual says) from a battery or a 13.8 V, ≥ 15–20 A supply is the right kind of number; AWG 18 is not.

AWG diameter: ASTM B258 formula (NBS lineage). Copper resistivity 10.371 Ω·cmil/ft at 20 °C is the usual annealed-copper figure. NEC ampacity tables are copyrighted and omitted. Radio current: Icom IC-2730A instruction manual on this shelf (personal-use copy).

Lumber, concrete, and pipe

Dimensional lumber — nominal vs dressed (U.S. dry, typical)

NominalActual (in)Board feet per linear foot (nominal)Note
1×4¾ × 3½0.27 / ft (nominal)see formula
1×6¾ × 5½0.44 / ft (nominal)see formula
1×8¾ × 7¼0.56 / ft (nominal)see formula
1×10¾ × 9¼0.72 / ft (nominal)see formula
1×12¾ × 11¼0.88 / ft (nominal)see formula
2×21½ × 1½0.25 / ft (nominal)see formula
2×41½ × 3½0.58 / ft (nominal)see formula
2×61½ × 5½0.92 / ft (nominal)see formula
2×81½ × 7¼1.21 / ft (nominal)see formula
2×101½ × 9¼1.54 / ft (nominal)see formula
2×121½ × 11¼1.88 / ft (nominal)see formula
4×43½ × 3½1.36 / ft (nominal)see formula
4×63½ × 5½2.15 / ft (nominal)see formula
6×65½ × 5½3.36 / ft (nominal)see formula

Board feet = thickness (in) × width (in) × length (ft) / 12, using nominal size when you buy construction lumber. A 10-foot 2×4 is 10 × 2 × 4 / 12 ≈ 6.67 bf. What you hold is 1½ × 3½. Green or rough-sawn lumber may be closer to nominal. Hardwood is often sold surfaced (S2S/S4S) in quarter and half-inch quarters — read the sticker.

Span tables are a building-code matter. The IRC and the lumber associations publish floor, ceiling, and rafter spans. Those tables are copyrighted and are not copied here. Species, grade, spacing (12 / 16 / 19.2 / 24 in on center), live load, and dead load all change the number. A “2×8 will span a small bedroom” is folklore, not a design. Use a current span table or an engineer, especially under snow load in the Wasatch, and especially for anything people sleep under.

Old shop rules of thumb you will still hear, offered only as orientation and not as a permit: a simple joist’s span in feet is often in the neighborhood of 1.5× its nominal depth in inches for ordinary floors (a 2×10 somewhere near 15 ft), and rafters are shorter than floor joists for the same section. That rule is crude, ignores species and grade, and is wrong in a lot of real rooms. Look the span up.

Nails (common, penny system)

The “d” is the penny size. Box nails are slimmer than common nails of the same penny. Sinkers and coated nails have their own shanks. A 16d common is the usual framing nail; a 16d sinker is a little shorter and slimmer.
SizeLength (in)Diameter (in) typ. commonUse
2d10.072light box
4d1½0.083small finish / box
6d20.102common
8d2½0.131common; very used in framing
10d30.148common
12d3¼0.148common
16d3½0.162common framing
20d40.192common
30d4½0.207common
40d50.225common
60d60.244common / spike

Concrete — volumetric field mixes

A 94 lb bag of portland cement is one cubic foot of cement as used in the old 1:2:3 talk. “Parts” below are by volume (shovels or buckets), cement : sand : coarse aggregate.

Mix (cement:sand:stone)Typical useNotes
1 : 2 : 3General purpose, sidewalks, modest footingsA very common field mix. Not a specified psi. Keep it stiff enough that it does not soup, wet enough that it consolidates.
1 : 2 : 4Mass, less highly stressed workLeaner.
1 : 1½ : 3Stronger, more cement-rich workUses more cement per yard.
1 : 3 (mortar, no stone)Brick / block mortar is its own specification (Type N, S, M)Do not use leftover concrete mix as if it were mortar, or leftover mortar as if it were concrete.

Pipe — steel / iron IPS, Schedule 40 and 80 (approximate ID)

Nominal pipe size is neither the ID nor, for ⅛–12 in, a simple match to the OD. OD is the same across schedules; wall thickness grows inward. These IDs are the usual published approximate bores, good for flow estimates, not for a machine fit.
Nominal (in)OD (in)Sch. 40 ID (in) approx.Sch. 80 ID (in) approx.
⅛0.4050.2690.215
¼0.5400.3640.302
⅜0.6750.4930.423
½0.8400.6220.546
¾1.0500.8240.742
11.3151.0490.957
1¼1.6601.3801.278
1½1.9001.6101.500
22.3752.0671.939
2½2.8752.4692.323
33.5003.0682.900
44.5004.0263.826

Copper tube (U.S. plumbing): Type K (thickest, often buried), Type L (typical interior water), Type M (thinner, often used in light residential — check the local code). Nominal ½, ¾, 1 in copper has an OD of ⅝, ⅞, and 1⅛ in (always ⅛ in over “nominal”).

PEX: follow the manufacturer’s crimp or expansion system and the temperature/pressure rating stamped on the tube. Do not treat PEX as if it were a copper soldering job.

Lumber dressed sizes: U.S. industry standard dry dimensions (American Softwood Lumber Standard lineage). Pipe OD/ID: standard IPS / ASME B36.10 approximate bores. Concrete mixes: traditional volumetric shop practice; a specified mix design supersedes them. Span tables omitted because they are code documents.

Knots, rope, chain, and slings

A knot that cannot be untied after a load is a mistake you will pay for in the dark. Dress the knot (make the turns sit where they belong), snug it before you trust it, and leave a tail. For life support (climbing, rappel, a person in a harness) use the knots and hardware you were taught, with a backup, not a knot you just read about.

Knots worth knowing

Rope — working load, not breaking load

The number on a hang-tag is often a minimum breaking strength. A working load is a fraction of that: commonly about 1/5 for a new, unused synthetic line in a straight pull (some rigging practices use 1/4 to 1/12 depending on the trade, shock load, and whether people are under it). Knots, bends, UV, mud, a sharp edge, and age all cut that down — a typical knot may cost 30–50% of the rope’s strength at the knot. There is no honest universal pound-rating in a pocket book. Read the tag; retire cut, glazed, or stiff rope; never stand under a load.

Order-of-magnitude only, for new rope, straight pull, manufacturer tag always wins: ⅜ in (10 mm) three-strand nylon often breaks in a range of several thousand pounds; ½ in more than that; polypropylene is usually weaker and floats; cheap “hardware-store” white line may be much weaker than a climbing or marine rope of the same diameter. Hemps and manilas are weaker when wet or rotten. Do not use a badly weathered line as if it were new.

Chain grades (U.S. common markings)

GradeTypical useNotes
30 (proof coil)Light general, barriersNot for overhead lifting. Often marked 3 or 30.
43 (high-test)Towing, binders, some loggingStill not a lifting chain unless the tag says so.
70 (transport)Truck tie-down, “binder chain”Usually gold chromate. Not for overhead lifting.
80 / 100 / 120Overhead lifting, when tagged and used with matching fittingsOnly a chain that is marked and used as a lifting chain, with rated hooks and a known sling angle, is a lifting chain.

Sling angle

When two legs of a sling share a load and the legs are not vertical, each leg sees more than half the load. Tension in each leg ≈ (Load / 2) / cos θ, or equivalently Load / (2 sin α) depending on which angle you measure — be consistent. A convenient form: if θ is the angle between the leg and the vertical, T = (W/2) / cos θ.

Angle from vertical (each leg)Tension in each of two legs, as a multiple of W/2What it feels like
0° (straight up)1.00 × (W/2)Best. Rare with a two-leg bridle.
30°1.15Still comfortable.
45°1.41Each leg sees about 70% of the whole load.
60°2.00Each leg already carries the full load.
75°3.86Dangerous; almost a horizontal pull on the attachments.

A wide, flat sling angle can tear the lifting points out even when the chain is “strong enough.” Keep the included angle reasonable, use a spreader if you must, and never put a person under a suspended load.

Knot mechanics and sling-angle factors are standard statics. Chain grade uses are the usual U.S. industrial distinctions; only a tagged lifting assembly is a lifting assembly. Rope strengths vary by fiber and manufacturer and are not guaranteed here.

Fuel properties

Fuellb / U.S. gal (approx.)Btu per U.S. gal (order of magnitude)Cautions
Gasoline (auto, approx.)6.3about 114,000–125,000highly flammable; vapors heavier than air; store in approved cans, away from the house
Diesel / #2 fuel oil7.1about 128,000–140,000less volatile than gasoline; still a fire and spill hazard; gels in deep cold unless winter-blended
Kerosene (K-1)6.7about 132,000–135,000heater and lamp fuel; use the grade the appliance specifies
Propane (LPG), liquid4.2about 91,500stored as a liquid under pressure; leaks down; odorant is added — a smell means get out and shut the valve if you can reach it safely
Ethanol (lab / fuel)6.6about 76,000hygroscopic; not a drop-in for every gasoline engine
Dry wood (seasoned, typical)— (see weights)about 6,000–8,000 per pound, air-dry, very species- and moisture-dependentseason before you need it; wet wood wastes heat and makes creosote
Charcoal (approx.)—about 12,000–14,000 per poundcarbon monoxide indoors can kill; never a brazier in a closed room

These heating values are typical published higher/lower-heat ranges rounded for field use, not a laboratory certificate. A gallon of gasoline in a 20% efficient small generator yields on the order of 7–8 kWh of electricity before you count the generator’s own losses — in practice many small sets are in the 1–2 kWh per gallon neighborhood at part load. Measure your own set if you depend on it.

Store fuel in approved containers, labeled, away from living spaces and ignition, and with a plan for spills. Rotating gasoline (and using stabilizer) matters; old gas varnishes small engines. Diesel lasts longer but grows bugs and takes up water. Propane does not go stale, but fittings, hoses, and regulators do.

Densities and heating values: typical figures consistent with NIST / DOE / EIA public ranges and older Smithsonian physical tables. Use a current SDS and the appliance manual for anything you burn indoors.

Weights of materials

Materiallb / ft3kg / m3Note
Water, 4 °C / 39 °F62.410008.34 lb/U.S. gal at ~60 °F is the usual shop figure
Ice57.2917floats; volume expands ~9% from water
Snow, loose / settled (very rough)5–2580–400varies wildly; do not size a roof from this
Steel (mild, average)49078500.283 lb/in3; 40.8 lb/ft2 per inch thick
Cast iron4507200approx.
Aluminum1692700about 1/3 of steel
Copper5598960bus bars, tubing, windings
Brass (typical)5308500alloy-dependent
Lead70811340dense; toxic dust — do not grind casually
Concrete (plain, cured, typ.)145–1502300–2400reinforced is heavier
Brick, masonry (typical)1201900varies
Sand, dry / wet (bulk)90–110 / 110–1301450–2100bulk, not solid quartz
Gravel, loose90–1201500–1900bulk
Portland cement (bulk)90–941440–1500a bag is 94 lb
Softwood, dry (pine, typ.)25–35400–560species and moisture dominate
Hardwood, dry (oak, typ.)40–50640–800white oak is toward the high end
Gasoline45–47720–750see Fuel
Diesel51–53820–850
Propane, liquid31–32500–510at ordinary tank temperature, approximate
Air, dry, 0 °C, 1 atm0.08071.29291.225 kg/m3 at 15 °C is a common figure
Earth, average packed (very rough)75–1251200–2000do not design a retaining wall from this

Steel plate weight (lb) ≈ 0.283 × thickness (in) × width (in) × length (in). A 4 ft × 8 ft sheet of ¼ in steel is about 327 lb. A 4×8 of ¾ in plywood is often 50–70 lb depending on grade; a 4×8 of ½ in drywall is about 50–55 lb.

Densities are typical handbook values (Smithsonian Physical Tables 7th ed. 1921 is on this shelf in reference/, with more modern typical construction figures). Alloys, moisture, and compaction move the number.

Water purification doses

The figures in this section are copied from EPA 816-F-15-003, Emergency Disinfection of Drinking Water, September 2017, which is already in this archive at food-water/water-purification/EPA_Emergency_Disinfection_of_Drinking_Water_Sept2017.pdf. Boiling or disinfection kills many disease-causing microorganisms. It does not remove heavy metals, salts, or most chemicals. Use only water that has been properly disinfected for drinking, cooking, prepared drinks, washing dishes, and brushing teeth.

Boil (preferred when you can)

  1. If the water is cloudy, let it settle and filter it through a clean cloth, paper towel, or coffee filter.
  2. Bring it to a rolling boil for at least one minute. At altitudes above 5,000 feet (1,500 meters), boil for three minutes. Much of the Wasatch Front’s higher towns and almost all of the ski-canyon settlements sit above that line; Salt Lake Valley itself is below it, but do not guess — if you are near 5,000 feet, use the three-minute time.
  3. Let it cool naturally. Store it in clean, covered containers.
  4. To improve the flat taste, add a pinch of salt to each quart or liter, or pour from one clean container into another several times.

Household bleach (when you cannot boil)

Use only regular, unscented chlorine bleach that is suitable for disinfection, with 6 or 8.25% sodium hypochlorite on the label. Do not use scented, color-safe, or bleaches with added cleaners. Use a fresh bottle stored at room temperature for less than one year. If the water is cloudy, let it settle and filter it first. Double the amount of bleach if the water is cloudy, colored, or very cold.

EPA 816-F-15-003, September 2017. Stir and let stand 30 minutes. The water should have a slight chlorine odor. If it does not, repeat the dose and wait another 15 minutes. If the taste is too strong, pour between clean containers and let it stand a few hours.
Volume of water6% bleach8.25% bleach
1 quart / 1 liter2 drops2 drops
1 gallon8 drops6 drops
2 gallons16 drops (¼ tsp)12 drops (⅛ tsp)
4 gallons⅓ tsp¼ tsp
8 gallons⅔ tsp½ tsp

Other EPA methods (summary)

Filters, UV pens, and chlorine-dioxide tablets have their own official directions and pore-size or log-reduction claims. A filter that does not say it handles cysts is not a giardia plan. Cloudy water should be prefiltered.

U.S. EPA, Office of Water, EPA 816-F-15-003, September 2017. Altitude rule is EPA’s (1 minute; 3 minutes above 5,000 feet). Ready.gov also discusses storing an emergency water supply (about one gallon per person per day is the usual planning figure).

Food storage and calories

A planning calorie is not a diet. Sedentary adults often sit near 1,800–2,400 kcal/day; cold, wet, hard labor can want much more. Children, pregnant people, and the ill have their own needs — use the USDA and medical manuals, not a guess, when it matters. Protein, fat, salt, and micronutrients (especially vitamin C, and iodine if you are far from iodized salt or seafood) catch up with a starch-only pile of rice.

Approximate energy of staples

Typical USDA FoodData Central-style values, rounded, for generic items. Brands and cook-water change the number. Use the label when you have one.
FoodAmountkcal (approx.)Note
White rice, raw100 g360–365about 1,600–1,700 per dry pound; cooked is mostly water
Brown rice, raw100 g360–370
Wheat flour, all-purpose100 g360–365a cup of floured AP is often ~120 g, not 100
Dry beans, typical100 g330–350must be fully cooked; raw red kidney beans are toxic
Rolled oats100 g380–390
Pasta, dry100 g360–370
White sugar100 g3874 kcal/g carbohydrate
Honey100 g300–305not for infants under 1 year
Vegetable oil100 g / 1 Tbsp (~14 g)884 / ~1209 kcal/g fat
Butter100 g / 1 Tbsp717 / ~100
Peanut butter100 g590–600check the jar; salt and sugar vary
Almonds, dry100 g575–580
Powdered milk, nonfat100 g350–360reconstitute per the bag
Cheddar cheese100 g400–410needs cool storage once opened
Canned tuna, in water, drained100 g85–130protein staple
Canned salmon100 g130–170
Canned corn, drained100 g60–80
Potato, raw100 g70–80
Eggs, whole, raw1 large (~50 g)~70–80cook thoroughly
Chicken, cooked meat, typical100 g160–190
Lean beef, cooked, typical100 g170–250fat changes this a lot
Hard candy / glucose100 g~380–400a useful but empty calorie
Dark chocolate, typical100 g500–600
Waterany0you still need it — calories are not hydration

Macronutrient rule of thumb: carbohydrate and protein ≈ 4 kcal/g, fat ≈ 9 kcal/g, alcohol ≈ 7 kcal/g (not a recommendation). A cup is a volume, not a weight — a cup of cooked rice is not a cup of dry rice.

Storage, quality, and safety

ItemTypical quality window (cool, dry, dark)Safety notes
Canned goods, high-acid (tomato, fruit, pickles)Quality often best within 12–18 monthsA sound, unbulged, unrusted can may last longer; discard bulging, spurting, or badly rusted cans. Never taste to “check” a suspect can.
Canned goods, low-acid (meat, vegetables, soups, beans)Quality often best within 2–5 years if cool and dryBotulism is the reason you do not eat from a bulged or leaking low-acid can, and the reason home canning of low-acid food must follow a tested pressure-canning process. See the Pantry wing and USDA/USU publications.
White rice, dry beans, dry pasta, sugar, salt — sealed, cool, dry, pest-proofYears, if kept dry and away from insects and miceBrown rice and whole-wheat flour go rancid sooner because of the oil in the bran. Rotate them faster.
Flour, opened oils, nuts, whole grainsMonths, not years, at room temperatureCool and dark helps. Rancid oil smells like crayons or putty — do not use it as if it were fresh.
Powdered milk, unopenedOften a year or more at cool room temperature; longer if kept truly cool and dryFollow the bag. Once opened, keep dry and rotate.
MREs and similar pouchesFollow the date and storage temperature on the caseHeat shortens life dramatically.
Honey, sugar, salt, distilled spiritsIndefinite as foods if kept clean and dry (honey may crystallize — that is not spoilage)Honey is not for infants under one year.
Water in food-grade containers, stored in the darkRotate every 6–12 months if you have no official long-life packagingOne gallon per person per day is the usual planning figure (drinking and hygiene).

Home canning: only a current, tested recipe from USDA or a land-grant extension (USU in Utah) is a canning recipe. An electric pressure cooker is not a pressure canner unless the official publication you are following says that exact model may be used that way. See the Personal Shelf / Utah Local extension notes in this archive.

Calorie figures: typical USDA FoodData Central values, rounded for field use. Storage windows: USDA / FoodSafety.gov style quality guidance, plus standard emergency-planning practice (Ready.gov water). Botulism and low-acid canning rules: USDA Complete Guide to Home Canning, in the pantry materials.

First-aid quick charts

This is a reminder sheet, not a course and not a diagnosis. The controlling manuals on this shelf are FM 4-25.11 First Aid, ATP 3-50.21, and the Hesperian Where There Is No Doctor (especially the first-aid chapters and the green pages). Get trained (Stop the Bleed, CPR) while you still can. For a medical emergency, use real medical help when it exists.

Scene, blood, breathing

  1. Do not become the second casualty. Look for traffic, fire, wires, gas, a still-armed attacker, or a collapsed trench before you step in.
  2. Life-threatening bleeding first when it is obviously that: apply firm direct pressure with a cloth; pack a deep wound if you were taught to; a tourniquet high and tight on a limb for life-threatening extremity bleeding if you were taught and pressure is not enough. Note the time. Do not take a tourniquet off as an experiment.
  3. Airway and breathing: talk to the person. If they cannot protect an airway, use the positioning and airway maneuvers you were trained in (and consider a possible neck injury). Recovery position if they are unresponsive but breathing and you must leave the airway unattended.
  4. If they are not breathing normally and you are trained, start CPR. Current public layperson emphasis is chest compressions in the center of the chest, hard and fast, about 100–120 per minute, allowing full recoil, in adults; trained rescuers may add breaths in a 30:2 ratio. An AED, if you have one, is used as soon as it is available. Get a current class — this paragraph is a memory aid for people who already had one.

Shock, burns, bone, cold, heat

Choking, opioid overdose (naloxone when you have it and were taught), childbirth, and mental-health crisis all have their own chapters in the manuals above. Do not invent a procedure from a one-line reminder.

Orientation only. See FM 4-25.11, ATP 3-50.21, Hesperian Where There Is No Doctor, and a current Stop the Bleed / CPR class. Compression rate 100–120/min is the widely published AHA figure; take a class for the current algorithm.

Medication dosing — official principles only

This archive will not invent a formulary. Doses for prescription drugs, and most pediatric doses, belong on the label, in a current official monograph, or in a manual that was written as one (the Hesperian green pages, a military or WHO formulary you actually have). A number remembered wrong is a poisoned patient.

Oral rehydration (pointer)

Dehydration from diarrhea is treated first with fluids. WHO publishes an official reduced-osmolarity ORS formula and, as a temporary household measure when the packets are gone, a sugar-and-salt drink with strict amounts. Use the official WHO or CDC wording if you must mix it, and do not “make it saltier so it works faster.” The Hesperian books and the medical wing carry the directions. This paragraph is a pointer to those sources, not a recipe invented here.

Principles only. Hesperian green pages, FM 4-25.11, WHO / CDC oral-rehydration publications, and the label on the product you actually have are the places to read a dose.

Weather and wind

Beaufort wind scale

Beaufort scale, land criteria, with the usual modern equivalent mean speeds. A gust is higher than the mean. NOAA / NWS and the original Beaufort / Met Office lineage.
ForceNamemph (mean, approx.)m/sLand signs
0Calm0–10–0.2Smoke rises straight.
1Light air1–30.3–1.5Smoke drifts.
2Light breeze4–71.6–3.3Leaves rustle; face feels wind.
3Gentle breeze8–123.4–5.4Leaves and small twigs move.
4Moderate breeze13–185.5–7.9Small branches move; dust and loose paper.
5Fresh breeze19–248.0–10.7Small trees sway.
6Strong breeze25–3110.8–13.8Large branches; whistling wires; umbrellas hard to use.
7Near gale32–3813.9–17.1Whole trees; inconvenience walking against it.
8Gale39–4617.2–20.7Twigs break; walking is hindered.
9Strong gale47–5420.8–24.4Slight structural damage possible.
10Storm55–6324.5–28.4Trees uprooted; considerable damage.
11Violent storm64–7228.5–32.6Widespread damage.
12Hurricane73+32.7+Extreme; rarely inland at this force except in a true hurricane or a violent tornado outflow.

Saffir–Simpson hurricane wind scale (NWS/NHC)

CategorySustained windsDamage (very brief)
174–95 mph (64–82 kt)Some damage to roofs, shingles, trees, power lines.
296–110 mphMajor roof and tree damage; likely power outages.
3 (major)111–129 mphDevastating: well-built homes can lose roof deck; electricity and water may be out for days to weeks.
4 (major)130–156 mphCatastrophic structural damage; area uninhabitable for weeks to months.
5 (major)157 mph or higherCatastrophic; a high percentage of framed homes destroyed.

Utah is not a hurricane coast, but the scale is useful if you ever have to read a national forecast, and a severe thunderstorm or a canyon downslope wind can still reach gale and storm force on the Beaufort scale. Lightning: if the time from flash to thunder is 30 seconds or less (about 6 miles), you are in range; get off ridges and put down long conductors. The “30–30” memory aid is: 30 seconds to take shelter, then wait 30 minutes after the last thunder.

Wind chill and heat index are NWS products. They are not the same as the thermometer. In a dry Utah winter, wind on bare skin will frostbite faster than the temperature alone suggests; in a dry summer, a 100 °F afternoon plus direct sun and no water is a heat-illness problem even when the “humidity is low.” See NWS charts if you have them, and the first-aid section.

Winter storms, avalanche, and flash flood in slot canyons and burn scars are the local killers more often than hurricanes. A weather radio (SAME / NOAA) and a glance at the sky still earn their keep.

Beaufort equivalents: standard modern meteorological presentation of a 19th-century public scale. Saffir–Simpson: U.S. National Hurricane Center / NWS, public. Lightning 30–30: widely published NWS public-safety guidance.

Radio band plans, Morse, and phonetics

A Technician-class amateur station Technician has full amateur privileges on 2 meters (144–148 MHz) and 70 centimeters (420–450 MHz) in the U.S. See the radio quick references and 47 CFR Part 97 in this demo's radio wing. Regional repeater lists are in the full edition. The next exam pool to study is General (2023–2027 pool, through 30 June 2027).

Everyday VHF/UHF frequencies (U.S. amateur)

Wavelength (approximate): λ (m) ≈ 300 / f (MHz). 146 MHz is about 2 m; 446 MHz is about 0.67 m. A quarter-wave on 2 m is about 19 inches (49 cm); on 70 cm about 6.3 inches (16 cm), before you account for velocity factor and how the antenna is built.

ICAO / ITU phonetic alphabet

LetterWordLetterWord
AAlfaNNovember
BBravoOOscar
CCharliePPapa
DDeltaQQuebec
EEchoRRomeo
FFoxtrotSSierra
GGolfTTango
HHotelUUniform
IIndiaVVictor
JJuliettWWhiskey
KKiloXX-ray
LLimaYYankee
MMikeZZulu

Figures are spoken as “tree,” “fife,” and “niner” in some aviation and traffic-handling practice (3, 5, 9) to survive a bad circuit. Amateur practice varies; be clear, not cute.

International Morse (ITU)

ChCodeChCodeChCode
A.-N-.1.----
B-...O---2..---
C-.-.P.--.3...--
D-..Q--.-4....-
E.R.-.5.....
F..-.S...6-....
G--.T-7--...
H....U..-8---..
I..V...-9----.
J.---W.--0-----
K-.-X-..-..-.-.-
L.-..Y-.--,--..--
M--Z--..?..--..
/-..-.+.-.-.=-...-
SOS...---...wait (AS).-...break (BT)-...-
end (AR).-.-.out (SK)...-.-error........

Timing: a dash is three dots; space between elements of a letter is one dot; between letters three; between words seven. SOS is a single prosign, not three letters with letter-spacing. Learn it by sound, not by looking at dots on a page, if you actually want to copy it.

Common Q-signals

CodeUsual meaning in amateur work
QTHLocation (my QTH is … / what is your QTH?)
QSYChange frequency
QRZWho is calling me?
QRMMan-made interference
QRNStatic / natural noise
QSBFading
QSOA contact
QSLAcknowledge / confirmation
QRPLow power
QROHigh power
QRXWait
QRVI am ready
QRTI am stopping (going off the air)
QRSSend more slowly
QLFnot official; ignore folklore

CTCSS (PL) tones, Hz

The usual 50-tone EIA / “PL” set, in hertz. A current official repeater directory already has the tone each repeater published. Do not invent a tone.
67.069.371.974.477.079.782.585.4
88.591.594.897.4100.0103.5107.2110.9
114.8118.8123.0127.3131.8136.5141.3146.2
151.4156.7159.8162.2165.5167.9171.3173.8
177.3179.9183.5186.2189.9192.8196.6199.5
203.5206.5210.7218.1225.7229.1233.6241.8
250.3254.1

RST: readability 1–5, strength 1–9, tone 1–9 (CW). “59” is the lazy signal report; use a real one when it would help the other station.

Morse and phonetics: ITU / ICAO public alphabets. Band facts: 47 CFR Part 97 and long-standing U.S. calling-frequency custom. CTCSS tone frequencies: standard EIA set.

Periodic table

Atomic numbers 1–118 with a conventional standard atomic weight (IUPAC). Values in brackets are the mass number of the longest-lived isotope of a radioelement that has no stable isotope. Use NIST or IUPAC if you need more figures than a pocket table.

ZSymbolNameAtomic weight
1HHydrogen1.008
2HeHelium4.0026
3LiLithium6.94
4BeBeryllium9.0122
5BBoron10.81
6CCarbon12.011
7NNitrogen14.007
8OOxygen15.999
9FFluorine18.998
10NeNeon20.180
11NaSodium22.990
12MgMagnesium24.305
13AlAluminium26.982
14SiSilicon28.085
15PPhosphorus30.974
16SSulfur32.06
17ClChlorine35.45
18ArArgon39.95
19KPotassium39.098
20CaCalcium40.078
21ScScandium44.956
22TiTitanium47.867
23VVanadium50.942
24CrChromium51.996
25MnManganese54.938
26FeIron55.845
27CoCobalt58.933
28NiNickel58.693
29CuCopper63.546
30ZnZinc65.38
31GaGallium69.723
32GeGermanium72.630
33AsArsenic74.922
34SeSelenium78.971
35BrBromine79.904
36KrKrypton83.798
37RbRubidium85.468
38SrStrontium87.62
39YYttrium88.906
40ZrZirconium91.224
41NbNiobium92.906
42MoMolybdenum95.95
43TcTechnetium[98]
44RuRuthenium101.07
45RhRhodium102.91
46PdPalladium106.42
47AgSilver107.87
48CdCadmium112.41
49InIndium114.82
50SnTin118.71
51SbAntimony121.76
52TeTellurium127.60
53IIodine126.90
54XeXenon131.29
55CsCaesium132.91
56BaBarium137.33
57LaLanthanum138.91
58CeCerium140.12
59PrPraseodymium140.91
60NdNeodymium144.24
61PmPromethium[145]
62SmSamarium150.36
63EuEuropium151.96
64GdGadolinium157.25
65TbTerbium158.93
66DyDysprosium162.50
67HoHolmium164.93
68ErErbium167.26
69TmThulium168.93
70YbYtterbium173.05
71LuLutetium174.97
72HfHafnium178.49
73TaTantalum180.95
74WTungsten183.84
75ReRhenium186.21
76OsOsmium190.23
77IrIridium192.22
78PtPlatinum195.08
79AuGold196.97
80HgMercury200.59
81TlThallium204.38
82PbLead207.2
83BiBismuth208.98
84PoPolonium[209]
85AtAstatine[210]
86RnRadon[222]
87FrFrancium[223]
88RaRadium[226]
89AcActinium[227]
90ThThorium232.04
91PaProtactinium231.04
92UUranium238.03
93NpNeptunium[237]
94PuPlutonium[244]
95AmAmericium[243]
96CmCurium[247]
97BkBerkelium[247]
98CfCalifornium[251]
99EsEinsteinium[252]
100FmFermium[257]
101MdMendelevium[258]
102NoNobelium[259]
103LrLawrencium[266]
104RfRutherfordium[267]
105DbDubnium[268]
106SgSeaborgium[269]
107BhBohrium[270]
108HsHassium[277]
109MtMeitnerium[278]
110DsDarmstadtium[281]
111RgRoentgenium[282]
112CnCopernicium[285]
113NhNihonium[286]
114FlFlerovium[289]
115McMoscovium[290]
116LvLivermorium[293]
117TsTennessine[294]
118OgOganesson[294]

Groups (vertical, IUPAC 1–18): 1 alkali metals (Li, Na, K, Rb, Cs, Fr), 2 alkaline earths, 17 halogens (F, Cl, Br, I, At, Ts), 18 noble gases. Periods are the rows. Lanthanoids 57–71 and actinoids 89–103 sit under the table in the usual display.

Common oxidation / valency reminders, not a chemistry course: H 1; O usually 2; Na 1; Ca 2; Al 3; C 4; Cl 1 (or more); Fe 2 or 3; Cu 1 or 2; N 3 or 5 in many compounds. Water is H2O; air is mostly N2 and O2.

Weights: IUPAC Standard Atomic Weights (conventional), as also used in NIST listings. Bracketed mass numbers are the usual handbook convention for radioelements.

Welding rods, torque reminders, and tire codes

SMAW (stick) electrode classification, very brief

An AWS E7018-style number: E electrode, 70 × 1,000 psi minimum tensile (70 ksi), 1 means all-position in the usual system, 8 is the coating and current type (low-hydrogen, iron-powder). E60xx is a 60 ksi class. The letters after a dash (A1, H4R, and so on) are extras. This is a memory aid, not a welding procedure specification.

ElectrodeCurrent (typical)Arc / slagUse and cautions
E6010DC+Deep, digging, a tight arcPipe, dirty or painted steel, root passes. Fast-freeze. Not the beginner’s first rod.
E6011AC or DC+Similar to 6010, runs on ACFarm and field work when you only have an AC “buzz box.”
E6013AC or DCSofter, easy slag, modest penetrationSheet, general repair, learners. Pretty beads, less muscle.
E7018DC+ (and some AC 7018A1 etc.)Low-hydrogen, strong, smoothStructural steel when the procedure calls for it. Keep the rods dry — a rod oven or a sealed can. Damp 7018 is how you get hydrogen cracks.
E7024AC or DCIron-powder, high deposition, flat and horizontalFillet welds where you can go fast on a flat joint.

Polarity: DC+ (reverse) puts more heat in the work for many electrodes; DC− (straight) puts more heat in the rod. AC is what a cheap transformer welder gives you. Clean the joint, ventilate (zinc, cadmium, and galvanized fumes are not a joke), and do not weld on a closed tank or a container that has held fuel.

Helmet shade (order of magnitude)

AWS / industry shade ranges, approximate. An auto-darkening helmet still needs a delay and a shade that covers the flash. If you see spots after a weld, the shade was too light — stop and fix it.
Process / currentShade (typical starting point)Note
Cutting, light / plasma (follow the machine)often 5–8The label on the goggles or the helmet wins.
SMAW (stick) under ~60 A, thin work9–10Too dark and you cannot see the puddle; too light and you burn your eyes.
SMAW ~60–160 A10–12Common farm-and-shop range.
SMAW ~160–250 A / heavier12–14
GMAW / FCAW similar currentssimilar to SMAWAuto-darkening helmets must still have a shade that is dark enough at the current you run.
GTAW (TIG) lower currentoften 9–12A gas-lens and a tight hood help you see.

Torque, again

The Grade 5 / Grade 8 table lives in the Fasteners section. Lug nuts, axle nuts, head bolts, and anything a shop manual lists are not in that table on purpose. Use a torque wrench that was calibrated sometime this decade, in the middle of its scale, with the socket fully seated. A click wrench left stored compressed, or used as a breaker bar, is a random-number generator.

Tire codes

A typical sidewall: P215/65R16 95H.

Electrode classification: AWS A5.1-style numbering, described in words. Helmet shades: typical AWS user-guide ranges, not a substitute for the current standard or the helmet’s label. Tire codes: U.S. DOT / tire-industry sidewall conventions, public.

Cooking measures and substitutions

AmountEqualsAlsoMetric / note
1 Tbsp3 tsp½ fl oz15 mL (approx.)
1 fl oz (U.S.)2 Tbsp6 tsp29.57 mL
¼ cup4 Tbsp2 fl oz59 mL
⅓ cup5 Tbsp + 1 tsp2⅔ fl oz79 mL
½ cup8 Tbsp4 fl oz118 mL
1 cup16 Tbsp8 fl oz237 mL (nutrition labels often use 240 mL)
1 pint2 cups16 fl oz473 mL
1 quart2 pints / 4 cups32 fl oz946 mL
1 gallon4 quarts128 fl oz3.785 L
1 stick of U.S. butter½ cup / 8 Tbsp4 oz (113 g)the wrapper is usually marked in Tbsp
1 lb butter2 cups / 4 sticks454 g
1 lb all-purpose flour (approx.)about 3½ cups spoonedvaries with packingweigh if it matters
1 lb granulated sugarabout 2¼ cups454 g
1 lb brown sugar, packedabout 2¼ cups
1 lb powdered sugar, unsiftedabout 3¾–4 cups
1 cup dry riceabout 3 cups cookedvariesbrown rice and pilaf methods differ
1 cup dry beansabout 2–3 cups cookedsoak and cook thoroughly
1 cup uncooked pasta, small shapesvaries widelyuse the bag’s yield

Common substitutions

If you needYou can sometimes useCaution
1 tsp baking powder⅓ tsp baking soda + ½ tsp cream of tartar (or a tested substitute)Do not swap baking soda and baking powder 1:1.
1 cup buttermilk1 Tbsp lemon juice or vinegar plus milk to make 1 cup, let stand a few minutesA cooking hack, not a cultured product.
1 cup whole milk½ cup evaporated milk + ½ cup water, or the bag’s powdered-milk directions
1 Tbsp fresh herb1 tsp dried of the same herb (start there and taste)Dried is more concentrated.
1 clove garlic¼–½ tsp garlic powder (very approximate)Powder is not the same flavor.
1 cup butter, for baking1 cup margarine is a rough stand-in in some recipes; oil is not a 1:1 swap for solid fat in pastryWhen the recipe is a bakery formula, follow it.
1 oz unsweetened chocolate3 Tbsp cocoa + 1 Tbsp fat, in a pinchTaste and texture will move.
1 cup cake flour1 cup less 2 Tbsp all-purpose, plus 2 Tbsp cornstarch, sifted — a common kitchen swapNot the same as real cake flour for a fine crumb.
1 egg, for binding (not for a custard)in some batters, 3 Tbsp of a beaten egg, or a tested “flax egg” (1 Tbsp ground flax + 3 Tbsp water)Custards, mayonnaise, and meringues are not the place to invent this.
1 cup sugardo not casually swap an equal volume of honey or a non-sugar sweetener without a tested recipeHoney is wetter and sweeter; reduce other liquid if you must experiment.
Active dry yeast vs instantThey are not always 1:1 in time or amount; follow the packetProof active dry in warm water if the packet says to.
High-altitude baking (Utah)Water boils cooler; cakes and breads often want a little more liquid, a little less leavening, a slightly hotter oven, or a tested high-altitude recipeUSU Extension and USDA have altitude notes. Salt Lake (~4,200 ft) is already high enough to notice; the canyons more so.

A pinch is under ⅛ tsp; a dash is a few drops or a shake. Oven temperatures: 250 °F = 120 °C, 300 = 150, 325 = 165, 350 = 175, 375 = 190, 400 = 200, 425 = 220, 450 = 230, 500 = 260, approximate and rounded to the numbers people actually set. Simmer is just below a boil; a rolling boil is obvious.

Food safety, not folklore: keep cold food cold and hot food hot. USDA’s usual home figures are refrigerate perishable food within 2 hours (1 hour if it is above 90 °F), cook poultry to 165 °F in the thickest part, ground meats to 160 °F, whole beef/pork steaks and roasts to at least 145 °F plus a rest, and leftovers to 165 °F — measured with a thermometer, not hope. Reheat canned leftovers in a pot, not in the can. See the pantry and USU materials for canning, which is a different problem.

Volume relations are U.S. customary kitchen measures (NIST-consistent). Substitutions are ordinary culinary practice, not a bakery specification. Internal temperatures: USDA FSIS public figures. High-altitude note: land-grant extension practice (USU).

Morse, signaling, and ground-to-air

Distress in almost any medium is a pattern of three: three whistle blasts, three gunshots, three fires, three flashes. SOS in Morse is ...---... as one prosign. A brightly colored panel, a mirror flash at an aircraft, and a fire that makes smoke against snow or a dark hill will be seen farther than a shout.

A signal mirror: sight the target through the hole or along your aimed reflection, and flash in deliberate bursts, not a continuous glitter that looks like water. At night, a light that is not a strobe should still be aimed, not waved at the clouds.

Ground-to-air (body and panel, survival-manual family)

The figures below follow the long-standing U.S. military survival-manual set (FM 21-76 and its successors, already in this archive). Make the marks large — on the order of several meters, high contrast, and in the open. Stay by them if you can. An aircraft may rock its wings for “message received,” or circle; do not walk in front of a landing helicopter.

Symbol (made with cloth, rocks, or your body as the manual shows)Usual meaning
VNeed help / require assistance
XNeed medical help
NNo, or negative
YYes, or affirmative
↑ (arrow)Going this way
▲ or a triangleprobably a safe place to land, in some lists — confirm in FM 21-76 before you stake a pilot’s life on a symbol you half-remember
a large, obvious SOSuniversally understood; use rocks, trampling, or contrasting cloth

Body signals in FM 21-76 include both arms up for “need help,” one arm up and one down for “need no help / all OK,” and pointing for direction. If you have the manual, use the pictures, not this sentence.

Radio distress: if you have a licensed amateur radio, a call on a local repeater, 146.52, or a known net (see radio/utah/nets.html) with your call sign, location, and the nature of the trouble is the adult way to do it. Marine and aviation distress frequencies are not toys and are not amateur allocations. 911, where it still works, still works.

SOS and the “rule of three” are customary distress signs. Ground-to-air panel meanings: U.S. Army FM 21-76 / later survival FMs, on this shelf in quickstart-72hr and survival/. Confirm a symbol in the manual before you rely on it.

Trig, roots, and inch decimals

Computed here from the usual formulae so the figures can be checked. Round-off is to four or five decimals, which is plenty for shop and field work.

Sine, cosine, and tangent — every 5°

Degreessincostan
00.00001.00000.0000
50.08720.99620.0875
100.17360.98480.1763
150.25880.96590.2679
200.34200.93970.3640
250.42260.90630.4663
300.50000.86600.5774
350.57360.81920.7002
400.64280.76600.8391
450.70710.70711.0000
500.76600.64281.1918
550.81920.57361.4281
600.86600.50001.7321
650.90630.42262.1445
700.93970.34202.7475
750.96590.25883.7321
800.98480.17365.6713
850.99620.087211.4301
901.00000.0000∞

Radians = degrees × π/180. Law of sines: a/sin A = b/sin B = c/sin C. Law of cosines: c² = a² + b² − 2ab cos C. A right triangle with opposite / hypotenuse = sin; adjacent / hypotenuse = cos; opposite / adjacent = tan.

Square roots, cube roots, and squares

n√n∛nn²
11.000001.000001
21.414211.259924
31.732051.442259
42.000001.5874016
52.236071.7099825
62.449491.8171236
72.645751.9129349
82.828432.0000064
93.000002.0800881
103.162282.15443100
113.316622.22398121
123.464102.28943144
133.605552.35133169
143.741662.41014196
153.872982.46621225
164.000002.51984256
174.123112.57128289
184.242642.62074324
194.358902.66840361
204.472142.71442400
244.898982.88450576
255.000002.92402625
305.477233.10723900
325.656853.174801024
366.000003.301931296
406.324563.419951600
486.928203.634242304
497.000003.659312401
507.071073.684032500
607.745973.914873600
648.000004.000004096
728.485284.160175184
808.944274.308876400
819.000004.326756561
909.486834.481408100
10010.000004.6415910000

Inch fractions (32nds) to decimal inches and millimetres

FractionDecimal inchesmm
1/32"0.0312500.794
1/16"0.0625001.587
3/32"0.0937502.381
1/8"0.1250003.175
5/32"0.1562503.969
3/16"0.1875004.762
7/32"0.2187505.556
1/4"0.2500006.350
9/32"0.2812507.144
5/16"0.3125007.938
11/32"0.3437508.731
3/8"0.3750009.525
13/32"0.40625010.319
7/16"0.43750011.112
15/32"0.46875011.906
1/2"0.50000012.700
17/32"0.53125013.494
9/16"0.56250014.287
19/32"0.59375015.081
5/8"0.62500015.875
21/32"0.65625016.669
11/16"0.68750017.462
23/32"0.71875018.256
3/4"0.75000019.050
25/32"0.78125019.844
13/16"0.81250020.637
27/32"0.84375021.431
7/8"0.87500022.225
29/32"0.90625023.019
15/16"0.93750023.812
31/32"0.96875024.606
1/1"1.00000025.400

1 in = 25.4 mm exactly (SI / NIST). Trigonometric values computed from the standard library.

Sheet metal, screws, nails, and fence cloth

Manufacturer’s standard steel sheet (approximate)

These are conventional U.S. steel-sheet gauge thicknesses used in the shop, not an ASTM or federal numbered standard, and not galvanized or aluminum gauge (those differ). Measure when it matters.

Gaugeinches (approx.)mm (approx.)
100.1353.42
120.1052.66
140.0751.90
160.0601.52
180.0481.21
200.0360.91
220.0300.76
240.0240.61
260.0180.45
280.0150.38

Wood-screw sizes (body and typical pilot)

NumberShank Ø in (approx.)Pilot in softwood (about)Pilot in hardwood (about)
#40.1121/163/32
#60.1385/647/64
#80.1643/321/8
#100.1907/649/64
#120.2161/85/32
#140.2429/6411/64

A pilot that is a little small and a shank clearance in the top piece will pull a joint tight. Soap or wax on the threads helps in hardwood. Do not use a wood screw as if it were a lag bolt in a structural joint.

Common nails — length and approximate count per pound

PennyLength (in)Nails per lb (about)
2d1about 850
4d1 1/2about 300
6d2about 180
8d2 1/2about 100
10d3about 65
16d3 1/2about 45
20d4about 30
60d6about 10

Penny-system lengths are the long-standing U.S. common-nail sizes (a 10d common is 3 in). Counts per pound are typical for common (not box or sinker) nails and vary by maker.

Wire cloth and poultry fence

MeshNote
1/4 in / 6 mm hardware clothMice, small snakes; preferred over chicken wire for a coop floor or run skirt.
1/2 in hardware clothWeasels still get through 1-inch holes; 1/2 in is a common run wall.
1 in chicken wire (hex netting)Keeps chickens in, not raccoons or dogs out. Use only as a visual/light fence, not as predator proofing.
2 in × 4 in welded stock fenceCattle/sheep panels; too open for poultry.
Buried apron, 12–18 in out, or 6–12 in downStops dogs, foxes, and raccoons from digging under a run. Utah coyotes and neighborhood dogs both dig.
Utah predators on a small flock are usually dogs, coyotes, raccoons, skunks, weasels, and hawks/owls. Night lockup in a tight coop, hardware cloth (not chicken wire), and a buried or aproned skirt do more than a taller flimsy fence. See the barnyard wing, including the USU Extension notes.

Voltage drop, 12-volt systems, and two-stroke mix

Approximate copper voltage drop (20 °C, DC or single-phase two-wire)

One-way length is the run to the load, not the round trip (the factor of 2 is already in the formula). VD = 2 × I × R × L ÷ 1000, with R in ohms per 1,000 ft and L in feet. The current columns are the current that produces about a 3% drop at the stated voltage and one-way length. This is arithmetic from the AWG resistance formula, not a reprint of the National Electrical Code and not an ampacity table. Heat, bundling, and insulation temperature are why a code table and this 3% chart are not the same thing.

AWGΩ / 1,000 ft (Cu, 20 °C)12 V, 10 ft, 3%12 V, 20 ft, 3%12 V, 50 ft, 3%120 V, 50 ft, 3%
186.3852.81.40.65.6
164.0154.52.20.99.0
142.5257.13.61.414.3
121.58811.35.72.322.7
100.99918.09.03.636.0
80.62828.714.35.757.3
60.39545.622.89.191.1
40.24872.436.214.5144.9
20.156115.257.623.0230.4
00.098183.291.636.6366.3

AWG diameters from the ASTM B258 / NBS formula used in the main electrical section; copper resistivity 10.371 Ω·cmil/ft at 20 °C.

12-volt practice

TopicNote
Typical passenger-car starting battery12 V nominal; about 200–800 CCA depending on size. Resting, full, is about 12.6–12.8 V; 12.0 V is roughly half; 11.9 V or less under no load is a sick battery. These are order-of-magnitude figures, not a load-test.
Series vs. parallelSeries adds voltage (two 12 V in series = 24 V, same amp-hours). Parallel adds amp-hours (two 12 V, 100 Ah in parallel = 12 V, 200 Ah) at the same voltage. Mix of ages or chemistries in parallel is a poor idea.
Starter cables / 12 V loadsA starter can draw hundreds of amps for a few seconds. Voltage drop in skinny leads is why jumper cables are fat. For lighting and radios, use the 3% table below.
Spark-plug gap (typical)Many small engines sit around 0.025–0.030 in; many automotive plugs around 0.030–0.045 in. The number on the engine or plug chart wins when you have it.

Two-stroke oil mix (U.S. gallon of gasoline)

Ratio (gas:oil)Oil to addNote
16:18 fl oz per U.S. gallonOlder two-strokes and some chainsaws; check the tool.
32:14 fl oz per U.S. gallonCommon mid-century ratio.
40:13.2 fl oz per U.S. gallonSome later tools.
50:12.6 fl oz per U.S. gallonVery common on modern two-stroke outdoor tools.
Use the ratio on the tool or in its manual when you have it. Too little oil scores a two-stroke; far too much smokes and fouls plugs. Mix in a marked can, not by guess in the tank. This is not a small-engine overhaul manual — see the future-ideas list for a later small-motors wing.

Board measure, stairs, roofs, tanks, insulation, and roof-water

Board feet and log rules

ItemFigure
Board foot1 in × 12 in × 1 ft, or 144 cubic inches, of nominal lumber. BF = thickness (in) × width (in) × length (ft) ÷ 12, using nominal thickness and width for the usual U.S. tally.
ExampleA 2×6×10 is 2×6×10÷12 = 10 board feet (nominal).
Doyle log rule (U.S. traditional, underestimates small logs)BF ≈ (D − 4)² × L ÷ 16, D = small-end diameter in inches inside bark, L = length in feet. A scale, not a cubic-foot volume.
International ¼-inch ruleA later, usually fairer log scale; Forest Products Laboratory discusses all three common U.S. rules (Doyle, Scribner, International) in the Wood Handbook in construction/.

U.S. board-foot definition and the Doyle form are long-standing lumber-trade arithmetic. Details and the other log rules are in the USDA Forest Products Laboratory Wood Handbook, already in construction/.

Stairs (carpenter’s rules of thumb)

TopicNote
Traditional carpenter’s rule2 × rise + run ≈ 24–25 in (some shops use 17–18 in for rise+run only). This is a comfort rule of thumb, not a building-code table. Current residential codes are copyrighted and are not copied here.
Comfortable range (field)Rise about 7–7½ in, run (tread) about 10–11 in, all risers equal within a small fraction of an inch.
Number of risersFloor-to-floor height in inches ÷ chosen rise, then adjust so every riser is the same. Treads = risers − 1 on a straight flight between floors.
Headroom and widthWatch headroom at the landing. A narrow, steep ship-ladder is a different animal from a house stair.

Common roof pitches — rafter length per foot of run

Pitch (rise/run)AngleRafter inches per foot of run (√(12²+rise²))
Pitch 3/1214.0°12.37
Pitch 4/1218.4°12.65
Pitch 5/1222.6°13.00
Pitch 6/1226.6°13.42
Pitch 8/1233.7°14.42
Pitch 12/1245.0°16.97

A 6/12 roof rises 6 in per foot of run. Rafter length (without overhang or birdsmouth) ≈ run × (the last column ÷ 12). Add overhang, and check the ridge and birdsmouth before you cut a stack of them.

Tank and pipe volumes

ShapeU.S. gallons
Rectangular tank, U.S. gallonsgallons ≈ length × width × depth (all in inches) ÷ 231, or feet × feet × feet × 7.48.
Cylinder, upright, U.S. gallonsgallons ≈ d² × h × 0.0034 if d and h are in inches; or d² × h × 5.88 if d and h are in feet. (π/4 × 7.48.)
Pipe volume, U.S. gallonsgallons ≈ d² × L × 0.0408, with inside diameter d in inches and length L in feet.
55-gallon drumAbout 22.5 in ID and 33 in inside height for a typical steel drum; do not treat “55” as a precise fill if you need one.
I-275 tote / IBC (typical)Often about 275 U.S. gallons (1,040 L) to the rated fill; check the plate.

R-values, order of magnitude (U.S. customary, per inch unless noted)

MaterialAbout
Still air film, inside (about)R-0.7
Wood, softwood, per inch (about)R-1.0 to R-1.4
Plywood, per inch (about)R-1.0
Dense mineral wool / fiberglass batt, per inch (about)R-3 to R-4
Expanded polystyrene (EPS), per inch (about)R-3.6 to R-4
Extruded polystyrene (XPS), per inch (about)R-5
Polyisocyanurate, per inch (about)R-5.5 to R-6.5 (age and facers matter)
Softwood-chip loose fill, per inch (about)R-2 to R-3
Snow, loose, per inch (about)R-1 (a variable insulator; wet snow is worse)
Single pane of glass (about)R-1
Insulating glass, two pane, air (about)R-2

Order-of-magnitude figures in the range published by DOE / ENERGY STAR and FPL wood-handbook style tables. Manufacturer’s labeled R-value, if you have the package, wins. These are not a code assembly table.

Rainwater catchment

ItemNote
RuleU.S. gallons ≈ roof area (ft²) × rainfall (inches) × 0.623. That is 1 inch of rain on 1 square foot ≈ 0.623 gallons.
Example, 1,000 ft² roof, 0.5 in rainabout 312 gallons before losses.
LossesFirst-flush, splash, overflow, and dirty roofs eat a lot. A first-flush diverter and a screened inlet are worth more than a bigger dirty tank.
Utah noteWasatch Front precipitation is modest and seasonal; a roof still makes useful garden or livestock water if you have the cistern and treat or filter to the use. Household drinking water still needs a real treatment step — see the water section and the EPA leaflet.

1 in of rain on 1 ft² is 1/12 ft³ ≈ 0.6233 U.S. gallons.

Altitude cooking, safe temperatures, cans, and water use

Approximate boiling point of water vs elevation

Utah’s Wasatch Front sits roughly 4,200 ft in the Salt Lake valley and higher in the benches and canyons. Water is cooler when it “boils,” food takes longer, and canning recipes have to be adjusted. Use the USDA altitude adjustments in the canning guides already in the pantry wing; do not guess at canning times from this table alone.

Elevation (ft)Boiling point °F (approx.)°C (approx.)
0 (sea level)212100.0
1,000210.299.0
2,000208.498.0
3,000206.697.0
4,000204.995.9
4,200 (about Salt Lake City)204.595.8
5,000203.195.1
6,000201.394.1
7,000199.593.1
8,000197.892.1
9,000196.091.1
10,000194.290.1

Approximate standard-atmosphere boiling points (about 1.8 °F or 1 °C drop per 1,000 ft in this range). A barometer and a thermometer beat the table if both are on hand.

USDA / FSIS minimum safe internal temperatures

FoodMinimum internal temperature
Poultry (whole, parts, ground, leftovers with poultry)165 °F (74 °C)
Ground meats (beef, pork, lamb, veal)160 °F (71 °C)
Beef, pork, lamb, veal steaks, chops, roasts145 °F (63 °C) and rest 3 minutes
Fish and shellfish145 °F (63 °C)
Egg dishes, leftovers, casseroles165 °F (74 °C)
Eggs, fried or boiled, if you are being carefulCook until the yolk and white are firm; dishes to 160 °F
Reheat leftovers165 °F (74 °C)
Hold hot food140 °F (60 °C) or hotter
Refrigerator40 °F (4 °C) or colder
Freezer0 °F (−18 °C) or colder

USDA Food Safety and Inspection Service safe-minimum-internal-temperature chart. A thermometer in the thickest part, not touching bone, is the test; color is not.

Common U.S. can sizes (approximate net)

CanAbout
#1 picnic / 10½ ozabout 1¼ cups
#300about 1¾ cups
#303about 2 cups
#2about 2½ cups
#2.5about 3½ cups
#3 cylinderabout 5¾ cups
#10 (institutional)about 12–13 cups (about 96–108 fl oz)

Can-size names are trade usage and have wandered over the years. Weigh or measure when a recipe is tight. A #10 can is the big institutional can, not “ten inches.”

Water-use planning figures

UseOrder of magnitude
Drinking and cooking, short-term emergency planningAbout 1 gallon per person per day is the usual Ready.gov / FEMA planning floor; more in heat or with nursing, illness, or dry food.
A flush toiletOften 1.6–6 gallons a flush depending on the fixture. A 5-gallon bucket and a latrine plan matter more than a pretty bathroom when the water stops.
A short showerOften 10–25 gallons.
Livestock (very rough)A dairy cow can drink tens of gallons a day; a horse often 5–15; a few chickens drink a small pan. Plan measured, not guessed, once you have animals.

FEMA / Ready.gov household water planning; fixture volumes are typical U.S. ranges, not a meter reading.

Wind chill, tornado scale, antennas, license classes, and field nav

NWS wind-chill figures (°F)

Rows are air temperature in °F; columns are wind speed in mph. The 2001 National Weather Service formula. It is defined for temperatures at or below 50 °F and winds of 3 mph and up; calmer air is just the thermometer. Frostbite times shorten quickly in the lower-right of this table — cover skin and get out of the wind.

Air °F \ Wind mph51015203040
40363432302827
30252119171513
20139641-1
101-4-7-9-12-15
0-11-16-19-22-26-29
-10-22-28-32-35-39-43
-20-34-41-45-48-53-57

NWS wind-chill formula (2001): 35.74 + 0.6215T − 35.75 V0.16 + 0.4275T V0.16, T in °F, V in mph.

Enhanced Fujita (EF) tornado scale (NWS / NOAA)

Category3-second gust, mph (EF)Damage in the official language, very briefly
EF065–85Light: branches, some shingles.
EF186–110Moderate: roofs stripped, mobile homes shifted.
EF2111–135Considerable: roofs off, large trees down.
EF3136–165Severe: stories of well-built houses destroyed.
EF4166–200Devastating: well-built houses leveled.
EF5>200Incredible: sturdy buildings destroyed.

Dipole and quarter-wave lengths (rule of thumb)

Half-wave dipole, feet ≈ 468 / f (MHz). Quarter-wave vertical, feet ≈ 234 / f (MHz). These include a typical velocity factor for a wire in the air; a fat tube, a tightly bent hamstick, or a loaded whip will not match the table. Cut long and trim against a meter.

Band (example frequency)½-wave ft (468/f)¼-wave ft (234/f)
80 m (3.6 MHz, mid-band)13065
40 m (7.1 MHz)65.933.0
20 m (14.2 MHz)32.916.5
15 m (21.2 MHz)22.111.0
10 m (28.5 MHz)16.48.2
6 m (50.1 MHz)9.34.7
2 m (146 MHz)3.211.60
70 cm (445 MHz)1.050.53

U.S. amateur license classes, in one paragraph each

ClassPrivileges, in short (47 CFR Part 97)
TechnicianAll amateur privileges above 50 MHz (with a few narrow exceptions in the rules). Limited HF: CW on parts of 80, 40, and 15 m; CW, data, and SSB on part of 10 m. This is the class that can run the 2 m / 70 cm radios in this station, including the IC-2730A and the Baofeng, on the amateur allocations.
GeneralAdds most of the remaining HF phone, CW, and data segments. The next exam up from Technician.
Amateur ExtraAll amateur privileges in Part 97.
Where to read it47 CFR §§ 97.301 and 97.305, not a club rumor. Band plans inside a band (which net sits where) are conventions; the FCC segments are the law.

47 CFR Part 97. This is not a complete band chart; the radio wing holds the official references and the station notes. Do not transmit outside your license and the Part 97 segments.

Pace, mils, declination, and the grid

TopicNote
Pace countCount every time the same foot hits, over a known 100 m or 100 yd, on the kind of ground you will walk. Recheck uphill, in snow, and at night. A typical adult might be 60–70 paces per 100 m on flat trail; yours is the one that matters.
Mils vs degreesNATO mil: 6,400 mils in a circle, so 1 mil ≈ 0.05625°, and 1° ≈ 17.78 mils. A 1-mil angle is about 1 unit of offset at 1,000 units of range (the “rule of mils”). Some older artillery used 6,000-mil circles — do not mix them.
Declination, Wasatch FrontMagnetic declination changes. NOAA / NCEI is the authority. In the early-to-mid 2020s the Wasatch Front has been on the order of 11° east (add easterly declination to a magnetic bearing to get true, or follow the diagram on your map). Read the current figure off a current map or a recorded NOAA value; do not trust this sentence in 2035.
USNG / MGRSThe U.S. National Grid is a USGS/FGDC overlay on UTM. A 10-digit USNG (for example a two-letter 100 km square plus 10 digits) is a 1 m square; 8 digits is 10 m; 6 digits is 100 m. Learn it before you need it; Utah maps in the maps wing are the place to practice.

pH, dilutions, welding rod notes, and tire codes

pH, in the usual aqueous sense

pHFamiliar examples
0–1Concentrated strong acids (battery acid is around 0–1). Treat as a burn hazard.
2–3Lemon juice, vinegar (around 2–3).
4–6Acidic soils, many fruits, black coffee.
7Neutral (pure water at 25 °C).
8–9Baking soda solution, seawater (around 8), many soaps.
10–11Ammonia household cleaners, some soaps.
12–14Household bleach (around 12–13), lye / drain cleaner (14 is a concentrated strong base). Burn hazard.

A short metal activity series

ItemNote
More easily oxidized (generally more reactive as metals)K, Na, Ca, Mg, Al, Zn, Fe, Ni, Sn, Pb, H, Cu, Ag, Au, Pt (gold and platinum at the noble end).
Why it mattersA more active metal can displace a less active one from solution (iron in copper sulfate plates copper and eats the iron). It is also a reminder about galvanic corrosion: do not leave a steel fitting hard-coupled to copper in a wet line and expect it to last.

Dilutions

RuleNote
C₁V₁ = C₂V₂The dilution equation for the same solute. Concentrated volume needed = (final concentration × final volume) ÷ starting concentration.
ExampleTo make 1 L of 1% from a 5% stock: 1 × 1 L ÷ 5 = 0.2 L of stock, plus water to 1 L.
Percent, field language1% w/v is 1 g in 100 mL. 1 ppm is 1 mg in 1 L (water). These are the usual dilute-aqueous approximations, not a chemistry-lab precise-mass definition.
BleachSee the EPA emergency-disinfection table in the water section. Do not mix bleach with ammonia or acids.

SMAW (stick) electrodes — starting notes, not a procedure

ElectrodeField notes
E6010 / E6011Fast-freeze, deep penetration, good on dirty or galvanized-in-the-field steel if you must; 6011 is the AC-friendly cousin of 6010. Typical 1/8 in starting current is often in the neighborhood of 80–130 A. These are starting points, not a WPS.
E6013Easy, shallow to moderate penetration, pretty bead for thin work and practice. Typical 1/8 in often around 80–120 A.
E7018Low-hydrogen, stronger weld metal (the 70 is 70 ksi tensile in the old AWS numbering). Keep the rod dry. Typical 1/8 in often around 90–140 A, usually DCEP. A wet 7018 is a hydrogen-crack problem, not just an ugly bead.
Polarity, very brieflyMany 6010/7018 setups run DCEP (reverse). 6013 is more forgiving. The rod and the machine manual win.
Oxy-fuel cutting (order of magnitude)A cutting oxygen jet, not the preheat flame, does the cut. Keep cylinders chained, acetylene under 15 psi in the hose, and flashback arrestors in place. This is not a cutting-torch course.

AWS classification numbers are the standard U.S. naming (E70xx = 70 ksi class, and so on). Currents are typical starting ranges used in shops and older public-domain / Army welding notes, not a reprint of a current AWS or manufacturer data sheet. Practice on scrap.

Tire sidewall codes

TopicNote
Reading a typical P-metric sidewallP215/65R16 95H — 215 mm section width, 65% aspect ratio (sidewall height / width), R = radial, 16 in rim, 95 = load index, H = speed rating. “P” is passenger; “LT” is light truck and is not the same load table.
Load index and speed ratingThe number and letter are indexes, not a license to ignore the vehicle placard. The placard on the door jamb (or the official load table) is the authority for that vehicle.
DOT dateThe last four digits of the DOT code are week and year of manufacture (for example 2319 is the 23rd week of 2019). Old rubber fails even with tread left.
PressureSet from the vehicle placard, cold, not from the sidewall maximum. The sidewall maximum is a limit, not a recommendation.

NHTSA / tire-industry standard P-metric reading. Vehicle placard and the tire maker’s load table win over a sidewall maximum or a memory of “32 pounds.”

Animal vitals, field sanitation, and pumping head

Typical resting vital-sign ranges

Teaching and extension ranges for calm adults, not a diagnosis and not a pediatric or breed-specific chart. Fright, heat, pregnancy, and tiny or giant breeds sit outside the middle of the range. See also the pet first-aid page in the Pets wing.

AnimalRectal (or oral, human) temperaturePulse / minBreaths / min
Dog (adult, resting)100.5–102.5 °F70–12015–30
Cat (adult, resting)100.5–102.5 °F140–22020–30
Chicken (adult, resting)105–107 °F250–30012–36
Horse (adult, resting)99–101 °F28–4410–24
Adult human (for comparison)about 97–99 °F oral60–10012–20

Latrine siting and camp hygiene

TopicNote
Siting, field rule from the Army hygiene family of manualsDownhill from the water source and the kitchen, and well away from both. A common teaching figure is on the order of 100 yards (about 90 m) from water and from food preparation when the ground will allow it. Never in a drainage that feeds the creek you drink from.
Soil and groundwaterA pit latrine in a high water table or in fractured rock can contaminate the well you still need. If you cannot get depth without hitting water, do not dig that hole there.
Cover and fliesA tight box, a lid, and lime or dry soil over deposits cut flies and smell. Hands get washed. This is not optional just because you are tired.
Closing outWhen the pit is used down to a couple of feet from the surface, fill, mound, and mark it so the next person does not dig it up.

Army field-hygiene teaching (the FM 21-10 / TP 4-02 family and the water and sanitation notes already in this archive). Distances are planning figures; local soil and slope can force a longer walk, not a shorter one toward the creek.

Pumping and head

TopicNote
Water is heavyA U.S. gallon weighs about 8.34 lb at ordinary temperatures. A 5-gallon bucket is about 42 lb plus the bucket.
Pressure and head1 psi ≈ 2.31 ft of water head; 1 ft of head ≈ 0.433 psi. A 23 ft lift is about 10 psi just to get it there, before friction.
Suction liftA perfect pump at sea level cannot pull more than about 33 ft of water; real pumps often sulk above 15–20 ft of suction lift. Put the pump down by the water when you can.
FrictionLong skinny hose eats head quickly. A short fat hose beats a long garden hose for moving volume.

Hydrostatic figures from the density of water and the usual foot-of-head / psi conversion (NIST-consistent). Suction-lift limits are physics plus ordinary pump reality, not a particular manufacturer’s curve.

These extra sections are meant to sit with the tables in the front of the book, not to replace the manuals they point to. If a figure here and a cited official source disagree, the official source wins.

64ths, survey measure, calories, heat index, knots, concrete, planting, and stars

Every 64th of an inch

FractionDecimal inchesmm
1/64"0.0156250.397
1/32"0.0312500.794
3/64"0.0468751.191
1/16"0.0625001.587
5/64"0.0781251.984
3/32"0.0937502.381
7/64"0.1093752.778
1/8"0.1250003.175
9/64"0.1406253.572
5/32"0.1562503.969
11/64"0.1718754.366
3/16"0.1875004.762
13/64"0.2031255.159
7/32"0.2187505.556
15/64"0.2343755.953
1/4"0.2500006.350
17/64"0.2656256.747
9/32"0.2812507.144
19/64"0.2968757.541
5/16"0.3125007.938
21/64"0.3281258.334
11/32"0.3437508.731
23/64"0.3593759.128
3/8"0.3750009.525
25/64"0.3906259.922
13/32"0.40625010.319
27/64"0.42187510.716
7/16"0.43750011.112
29/64"0.45312511.509
15/32"0.46875011.906
31/64"0.48437512.303
1/2"0.50000012.700
33/64"0.51562513.097
17/32"0.53125013.494
35/64"0.54687513.891
9/16"0.56250014.287
37/64"0.57812514.684
19/32"0.59375015.081
39/64"0.60937515.478
5/8"0.62500015.875
41/64"0.64062516.272
21/32"0.65625016.669
43/64"0.67187517.066
11/16"0.68750017.462
45/64"0.70312517.859
23/32"0.71875018.256
47/64"0.73437518.653
3/4"0.75000019.050
49/64"0.76562519.447
25/32"0.78125019.844
51/64"0.79687520.241
13/16"0.81250020.637
53/64"0.82812521.034
27/32"0.84375021.431
55/64"0.85937521.828
7/8"0.87500022.225
57/64"0.89062522.622
29/32"0.90625023.019
59/64"0.92187523.416
15/16"0.93750023.812
61/64"0.95312524.209
31/32"0.96875024.606
63/64"0.98437525.003

1 in = 25.4 mm exactly.

Survey, sea, and specialty units

UnitU.S. / customaryNotes / SI
1 link (Gunter's)7.92 in0.201 m
1 rod / pole / perch16.5 ft (25 links)5.029 m
1 chain (Gunter's)66 ft (100 links, 4 rods)20.117 m
1 furlong660 ft (10 chains)201.17 m
1 statute mile5,280 ft (80 chains)1,609.344 m exactly (US, 1959)
1 acre43,560 ft² (10 square chains)4,046.86 m²
1 section (U.S. Public Land Survey, nominal)1 mile², 640 acresA real section can be short or long; read the plat.
1 township (nominal)36 sections, 6 miles squareSame caution as sections.
1 nautical mile (international)1,852 m exactlyabout 6,076.12 ft
1 fathom6 ft1.829 m
1 cable (U.S. Navy traditional, about)120 fathoms / 720 ftVaries by navy; do not survey with it.
Troy ounce480 grains, 31.1035 gPrecious metals. Not the 28.35 g avoirdupois ounce.
Avoirdupois ounce437.5 grains, 28.3495 gOrdinary U.S. food and shop ounce.
1 stone (UK)14 lb avoirdupois6.350 kg
1 hundredweight, U.S. (short cwt)100 lb45.36 kg
1 long (Imperial) hundredweight112 lb50.80 kg
Flow, useful identity1 cfs = 448.8 gpm (U.S.)1 U.S. gpm = 0.0631 L/s

Gunter's chain and the U.S. Public Land Survey units are the reason rural property in Utah is still talked about in chains and acres. The international nautical mile is 1,852 m (SI brochure / IHO). The 1959 international yard and pound make the statute mile 1,609.344 m exactly.

More staple energy figures (approximate)

Foodkcal (approximate)
Wheat, white flour, 100 gabout 364
Wheat, whole-grain flour, 100 gabout 340
Dry white rice, 100 gabout 365
Dry brown rice, 100 gabout 370
Dry rolled oats, 100 gabout 380
Dry pinto beans, 100 gabout 347
Dry lentils, 100 gabout 352
Dry pasta, 100 gabout 370
Potato, raw, 100 gabout 77
White sugar, 100 gabout 387
Honey, 100 gabout 304
Butter, 100 gabout 717
Vegetable oil, 100 g (about 7 Tbsp)about 884
Peanut butter, 100 gabout 588
Whole milk, 100 g (about 3.4 fl oz)about 61
Cheddar, 100 gabout 400
Eggs, whole, 100 g (about 2 large)about 143
Chicken, dark meat, roasted, 100 gabout 200
Beef, ground, 80% lean, cooked, 100 gabout 270
Salmon, cooked, 100 gabout 200
Hard red wheat, dry berries, 1 lbabout 1,500–1,600
U.S. gallon of whole milkabout 2,400
U.S. gallon of vegetable oilabout 31,000 (do not drink a gallon of oil; this is energy density)
A very rough adult field ration target2,000–3,000 kcal/day depending on cold, work, size, and whether you are trying to maintain weight

USDA FoodData Central typical values, rounded. Brands and moisture move the number. A food scale and the pantry guides beat a memorized calorie.

Heat index, shade (°F) — NWS-style chart

Air temperature in the first column, relative humidity across the top, apparent temperature in the cells. These are the usual National Weather Service shade, light-wind values. Full sun can feel substantially hotter. A dash means you are off the usual published chart — treat it as dangerous either way. Heat index is not a bare-thermometer reading and is not defined the same way as wet-bulb globe temperature.

Temp °F \ RH40%50%60%70%80%90%
80808182838486
84858688909396
88919396100104109
9298102108114121128
96107113121130137143
100118127137148——
104131142————

National Weather Service heat-index chart (public NWS values, shade).

Knots and remaining strength (order of magnitude)

These efficiencies are order-of-magnitude field figures from rope-work teaching, not a manufacturer's test for your exact rope. A knot is the weak point. Never treat a working load as a breaking load (see the knots section earlier).

KnotVery rough remaining strength
Bowlineoften around 70% of the rope's listed strength, well tied in a suitable rope
Figure-eight follow-through / knotoften around 75–80%
Square (reef) knotoften around 50% or worse, and it can capsize — a binding knot, not a life-support knot
Sheet bendoften around 50–65%; double it for slippery or unequal lines
Clove hitchcan slip when slack or yanked; back it up
Trucker's hitcha purchase, not a pretty knot; expect mid-range efficiency and watch what you hitch to
Overhand / thumb knot in the bight as a stopperbulky; weakens the rope at the knot

Concrete bags, slabs, and block counts

TopicFigure
80 lb bag of Portland cementA common bag. A 94 lb bag is the old “1 cubic foot” sack still used in some mix math.
60 or 80 lb bags of pre-mix concreteAn 80 lb bag of pre-mix often yields about 0.60 ft³; a 60 lb bag about 0.45 ft³. Read the bag. 27 ft³ = 1 yd³, so you need on the order of 45 of the 80 lb bags per cubic yard.
Coverage, 4 in slab1 yd³ covers 27 ft² at 12 in thick, so about 81 ft² at 4 in, before waste. Order extra.
Mortar, very roughA typical 80 lb bag of mortar mix, plus sand if it is not pre-blended as a complete mix, is a small-job figure — read the bag for “number of brick or block.” A concrete masonry block 8×8×16 takes a lot more mortar than a face brick.
8×8×16 block, wall areaEach block face is 8 in × 16 in = 0.89 ft², so about 113 block per 100 ft² of wall, plus corners and waste. That is a count, not a structural design.

Soil temperatures and planting (field, not a Utah calendar)

Crop groupTypical minimum soil temperature to plant
Peas, spinach, lettuce (cool)often 35–45 °F and up
Beets, carrots, cabbage, onionsoften 40–50 °F
Beans, sweet corn, cucumbersoften 60 °F and up; beans rot in cold wet ground
Tomatoes, peppers, squash, melon (warm)often 65–70 °F and up; do not rush these in a Wasatch Front April
Potatoesoften 45–55 °F, after the worst of a hard freeze is past
A soil thermometerBeats the calendar. Utah valley last-spring and first-fall frost dates move by town and bench; use NOAA / NCEI normals for your site rather than a single “Utah” date.

Common land-grant / USDA garden teaching ranges. A soil thermometer and your local NOAA frost normals beat a copied calendar.

Drinking-water order of magnitude, people and animals

WhoVery rough daily water
Adult human, planning floor1 gallon/day drinking and cooking, more in heat (Ready.gov).
Lactating woman, hard work, or heatOften well above the 1-gallon floor.
Dog, typical petAbout ½–1+ oz per pound of body weight per day, more in heat or on dry food; a 50 lb dog often drinks on the order of a quart to a couple of quarts.
CatLess than a dog, but canned food vs dry changes it a lot. Always have water out.
Laying henOn the order of 0.2–0.5 pint (about 0.1–0.25 L) a day, more in heat; a small flock's waterer goes faster than people expect.
HorseOften 5–15 gallons/day, more in heat or on dry hay.
Cattle, cow-calf vs dairyA dry cow may drink on the order of 10–20 gallons; a milking dairy cow can be much more (tens of gallons). Do not plan a dairy on a hose you have not measured.

A few sky landmarks (Northern Hemisphere, mid-latitudes)

LandmarkHow you use it
Polaris (North Star)End of the Little Dipper's handle; almost on the north celestial pole. Altitude ≈ your latitude. See the navigation section.
Big Dipper (Ursa Major)The two pointer stars at the bowl's front point to Polaris, about five times the pointer-span onward.
CassiopeiaThe W, on the opposite side of Polaris from the Dipper; also points you to the pole when the Dipper is low.
OrionWinter sky. The belt points to Sirius (southeast of the belt in the northern hemisphere evening) and, the other way, toward Aldebaran / Taurus.
SiriusBrightest star in the night sky; follow Orion's belt.
Summer TriangleVega, Deneb, and Altair; a high, obvious summer/autumn landmark.
Scorpius / AntaresLow summer southern sky in Utah; reddish Antares in the scorpion's body. Watch that you do not confuse it with a planet.
PlanetsDo not move with the star field over weeks; they wander. A planet can be brighter than most stars and will not twinkle as much.

Planets and the Moon will sit among these and confuse a hasty look. The navigation section in the front of the book covers Polaris and declination in more detail.

Useful constants and source list

ConstantValueNote
Speed of light in vacuum c299,792,458 m/s exactlySI 2019; the metre is defined from this
Standard gravity g9.80665 m/s² exactlyconventional standard; local g is a bit less in high Utah, a bit more at sea level in some places
Planck constant h6.62607015×10−34 J·s exactlySI 2019
Elementary charge e1.602176634×10−19 C exactlySI 2019
Avogadro constant NA6.02214076×1023 mol−1 exactlySI 2019
Boltzmann constant k1.380649×10−23 J/K exactlySI 2019
Molar gas constant R = NA k8.314462618 J/(mol·K)derived, exact from the above
Standard atmosphere101,325 Pa14.69595 psi; 760 mmHg
Ice point (ITS convention)273.15 K = 0 °C
Stefan–Boltzmann σ5.670374…×10−8 W/(m²·K⁴)derived
Electron mass me9.1093837×10−31 kgCODATA / NIST
Proton mass mp1.6726219×10−27 kgCODATA / NIST
Atomic mass unit u1.660539×10−27 kg1/12 of a ¹²C atom
Faraday constant F96,485.33 C/molNA e
Speed of sound, dry air, 20 °C, 1 atmabout 343 m/s (1,125 ft/s)increases with the square root of absolute temperature
Standard density of dry air, 15 °C, 1 atm1.225 kg/m³ICAO standard-atmosphere sea-level figure
Water density, 4 °C999.97 kg/m³ ≈ 10008.34 lb/U.S. gal at ~60 °F is the shop figure
Latent heat of fusion, waterabout 334 kJ/kg (144 Btu/lb)ice to water at 0 °C
Latent heat of vaporization, water, 100 °Cabout 2256 kJ/kg (970 Btu/lb)why a steam burn is so nasty
Specific heat of liquid waterabout 4.18 kJ/(kg·K) or 1 Btu/(lb·°F)the original calorie
π3.141592653589793
e2.718281828459045
Golden ratio φ (1+√5)/2 ≈ 1.618034
ln 102.302585092994log10 x = ln x / ln 10
1 radian180/π ° ≈ 57.2957795°

Where the figures came from

This book is a compilation of publicly citable facts for offline personal use at Installation 343. It is not Glover’s Pocket Ref, not a current Machinery’s Handbook, and not a substitute for the manuals it points to. If a figure here and a cited official source disagree, the official source wins.

Compiled 15 November 2026, America/Denver.